Investigation on the Energy Saving Potential of Using a Novel Dew Point Cooling System in Data Centres

被引:11
|
作者
Bi, Yin [1 ,2 ]
Wang, Yugang [1 ,3 ]
Ma, Xiaoli [1 ]
Zhao, Xudong [1 ]
机构
[1] Univ Hull, Sch Engn & Comp Sci, Kingston Upon Hull HU6 7RX, Yorks, England
[2] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou 510006, Guangdong, Peoples R China
[3] Jimei Univ, Sch Mech & Energy Engn, Xiamen 361021, Peoples R China
来源
ENERGIES | 2017年 / 10卷 / 11期
基金
英国工程与自然科学研究理事会; 欧盟地平线“2020”;
关键词
dew point cooling; data centres; energy saving; energy usage effectiveness; cooling load; INDIRECT EVAPORATIVE COOLER; COUNTER-FLOW; HEAT-EXCHANGERS; PERFORMANCE; OPTIMIZATION; CONSERVATION;
D O I
10.3390/en10111732
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Information technology (IT) has brought significant changes in people's lives. As an important part of the IT industry, data centres (DCs) have been rapidly growing in both the number and size over the past 40 years. Around 30% to 40% of electricity consumption in DCs is used for space cooling, thus leading to very inefficient DC operation. To identify ways to reduce the energy consumption for space cooling and increase the energy efficiency of DCs' operation, a dedicated investigation into the energy usage in DCs has been undertaken and a novel high performance dew point cooling system was introduced into a DC operational scheme. Based on the cooling load in DCs, a case study was carried out to evaluate the energy consumptions and energy usage effectiveness when using the novel dew point cooling system in different scales of DCs in various climates. It was found that by using the novel dew point cooling system, for 10 typical climates a DC can have a much lower power usage effectiveness (PUE) of 1.10 to 1.22 compared to that of 1.7 to 3.7 by using existing traditional cooling systems, leading to significantly increased energy efficiency of the DC operation. In addition, the energy performance by managing the cooling air supply at the different levels in DCs, i.e., room, row and rack level, was simulated by using a dynamic computer model. It was found that cooling air supply at rack level can provide a higher energy efficiency in DCs. Based on the above work, the energy saving potential in DCs was conducted by comparing DCs using an the novel dew point cooling system and the optimum management scheme for the cooling air supply to that using traditional air cooling systems and the same supply air management. Annual electricity consumptions for the two cases were given. It was found that by using the novel dew point cooling system and optimum management system for the cooling air supply, an 87.7-91.6% electricity consumption saving for space cooling in DCs could be achieved in 10 typical cities at 10 selected climatic conditions.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] STRUCTURE OPTIMIZATION AND ENERGY SAVING POTENTIAL INVESTIGATION OF NOVEL INTERGRATED VENTILATED PV ROOF
    Peng J.
    Zhang Q.
    Zhou C.
    Zhang S.
    Zhang F.
    Luo Y.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (12): : 24 - 32
  • [42] Energy saving potential of thermoelectric modules integrated into liquid desiccant system for solution heating and cooling
    Lim, Hansol
    Jeong, Jae-Weon
    APPLIED THERMAL ENGINEERING, 2018, 136 : 49 - 62
  • [43] Energy Saving Potential of Passive and Low Energy Cooling Techniques in Buildings in Ghana
    Amos-Abanyie, Samuel
    Akuffo, Fred Ohene
    Kutin-Sanwu, Victor
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 130 - 137
  • [44] Computational fluid dynamic investigation of liquid rack cooling in data centres
    Almoli, Ali
    Thompson, Adam
    Kapur, Nikil
    Summers, Jonathan
    Thompson, Harvey
    Hannah, George
    APPLIED ENERGY, 2012, 89 (01) : 150 - 155
  • [45] Energy saving obtainable by applying a commercially available M-cycle evaporative cooling system to the air conditioning of an office building in North Italy
    Zanchini, Enzo
    Naldi, Claudia
    ENERGY, 2019, 179 : 975 - 988
  • [46] Radiative free cooling for energy and water saving in data centers
    Aili, Ablimit
    Long, Wenjun
    Cao, Zhiwei
    Wen, Yonggang
    APPLIED ENERGY, 2024, 359
  • [47] Saving energy for the data collection point in WBAN network
    Nguyen-Duc, Toan
    Kamioka, Eiji
    FIFTH INTERNATIONAL CONFERENCE ON WIRELESS AND OPTICAL COMMUNICATIONS, 2017, 10465
  • [48] Energy-saving potential of separated two-phase thermosiphon loops for data center cooling
    Sulaiman, Mohammed W.
    Daraghmeh, Hafiz M.
    Wang, Chi-Chuan
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 141 (01) : 245 - 265
  • [49] Energy-saving potential of separated two-phase thermosiphon loops for data center cooling
    Mohammed W. Sulaiman
    Hafiz M. Daraghmeh
    Chi-Chuan Wang
    Journal of Thermal Analysis and Calorimetry, 2020, 141 : 245 - 265
  • [50] Energy-saving potential of a passive cooling system for thermal energy management of a residential building in Jaipur City, India
    Kumar, S.
    Sheeja, R.
    Jospher, Abraham J. S.
    Krishnan, G. Sai
    Chandrasekar
    AroulRaj, Antony
    MATERIALS TODAY-PROCEEDINGS, 2021, 43 : 1471 - 1477