Investigation on the Energy Saving Potential of Using a Novel Dew Point Cooling System in Data Centres

被引:11
|
作者
Bi, Yin [1 ,2 ]
Wang, Yugang [1 ,3 ]
Ma, Xiaoli [1 ]
Zhao, Xudong [1 ]
机构
[1] Univ Hull, Sch Engn & Comp Sci, Kingston Upon Hull HU6 7RX, Yorks, England
[2] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou 510006, Guangdong, Peoples R China
[3] Jimei Univ, Sch Mech & Energy Engn, Xiamen 361021, Peoples R China
来源
ENERGIES | 2017年 / 10卷 / 11期
基金
英国工程与自然科学研究理事会; 欧盟地平线“2020”;
关键词
dew point cooling; data centres; energy saving; energy usage effectiveness; cooling load; INDIRECT EVAPORATIVE COOLER; COUNTER-FLOW; HEAT-EXCHANGERS; PERFORMANCE; OPTIMIZATION; CONSERVATION;
D O I
10.3390/en10111732
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Information technology (IT) has brought significant changes in people's lives. As an important part of the IT industry, data centres (DCs) have been rapidly growing in both the number and size over the past 40 years. Around 30% to 40% of electricity consumption in DCs is used for space cooling, thus leading to very inefficient DC operation. To identify ways to reduce the energy consumption for space cooling and increase the energy efficiency of DCs' operation, a dedicated investigation into the energy usage in DCs has been undertaken and a novel high performance dew point cooling system was introduced into a DC operational scheme. Based on the cooling load in DCs, a case study was carried out to evaluate the energy consumptions and energy usage effectiveness when using the novel dew point cooling system in different scales of DCs in various climates. It was found that by using the novel dew point cooling system, for 10 typical climates a DC can have a much lower power usage effectiveness (PUE) of 1.10 to 1.22 compared to that of 1.7 to 3.7 by using existing traditional cooling systems, leading to significantly increased energy efficiency of the DC operation. In addition, the energy performance by managing the cooling air supply at the different levels in DCs, i.e., room, row and rack level, was simulated by using a dynamic computer model. It was found that cooling air supply at rack level can provide a higher energy efficiency in DCs. Based on the above work, the energy saving potential in DCs was conducted by comparing DCs using an the novel dew point cooling system and the optimum management scheme for the cooling air supply to that using traditional air cooling systems and the same supply air management. Annual electricity consumptions for the two cases were given. It was found that by using the novel dew point cooling system and optimum management system for the cooling air supply, an 87.7-91.6% electricity consumption saving for space cooling in DCs could be achieved in 10 typical cities at 10 selected climatic conditions.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Design improvement of central cooling plant for energy saving using cooling tower water
    Vakiloroaya, Vahid
    Fakhar, Ahmad
    Samali, Bijan
    Pishghadam, Kambiz
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2013, 5 (05)
  • [32] Evaluation of energy saving potential of HVAC system by operation data with uncertainties
    Shi, Wantao
    Jin, Xinqiao
    Wang, Yijun
    ENERGY AND BUILDINGS, 2019, 204
  • [33] Projecting global water footprints diminution of a dew-point cooling system: Sustainability approach assisted with energetic and economic assessment
    Tariq, Rasikh
    Sheikh, Nadeem Ahmed
    Livas-Garcia, A.
    Xaman, J.
    Bassam, A.
    Maisotsenko, Valeriy
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2021, 140
  • [34] Comprehensive energy saving evaluation of circulating cooling water system based on combination weighting method
    Zhu, Xiaochen
    Niu, Dapeng
    Wang, Xu
    Wang, Fuli
    Jia, Mingxing
    APPLIED THERMAL ENGINEERING, 2019, 157
  • [35] A study on energy saving of cooling/reheating system using compact heat exchanger
    Seong-Yeon Yoo
    Jin-Hyuck Kim
    Myoung-Seok Jie
    Journal of Mechanical Science and Technology, 2010, 24 : 887 - 892
  • [36] Energy saving analysis of evaporative cooling composite air conditioning system for data centers
    Han, Zongwei
    Sun, Xiaoqing
    Wei, Haotian
    Ji, Qiang
    Xue, Da
    APPLIED THERMAL ENGINEERING, 2021, 186
  • [37] Data centers cooling: A critical review of techniques, challenges, and energy saving solutions
    Alkrush, Ahmed A.
    Salem, Mohamed S.
    Abdelrehim, O.
    Hegazi, A. A.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 160 : 246 - 262
  • [38] Novel battery thermal management via scalable dew-point evaporative cooling
    Lin, Jie
    Chu, Howie N.
    Thu, Kyaw
    Wojtala, Malgorzata
    Gao, Fei
    Chua, Kian Jon
    ENERGY CONVERSION AND MANAGEMENT, 2023, 283
  • [39] Energy saving potential of thermoelectric modules integrated into liquid desiccant system for solution heating and cooling
    Lim, Hansol
    Jeong, Jae-Weon
    APPLIED THERMAL ENGINEERING, 2018, 136 : 49 - 62
  • [40] Energy saving potential of a two-pipe system for simultaneous heating and cooling of office buildings
    Maccarini, Alessandro
    Wetter, Michael
    Afshari, Alireza
    Hultmark, Goran
    Bergsoe, Niels C.
    Vorre, Anders
    ENERGY AND BUILDINGS, 2017, 134 : 234 - 247