Investigation on the Energy Saving Potential of Using a Novel Dew Point Cooling System in Data Centres

被引:11
|
作者
Bi, Yin [1 ,2 ]
Wang, Yugang [1 ,3 ]
Ma, Xiaoli [1 ]
Zhao, Xudong [1 ]
机构
[1] Univ Hull, Sch Engn & Comp Sci, Kingston Upon Hull HU6 7RX, Yorks, England
[2] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou 510006, Guangdong, Peoples R China
[3] Jimei Univ, Sch Mech & Energy Engn, Xiamen 361021, Peoples R China
来源
ENERGIES | 2017年 / 10卷 / 11期
基金
英国工程与自然科学研究理事会; 欧盟地平线“2020”;
关键词
dew point cooling; data centres; energy saving; energy usage effectiveness; cooling load; INDIRECT EVAPORATIVE COOLER; COUNTER-FLOW; HEAT-EXCHANGERS; PERFORMANCE; OPTIMIZATION; CONSERVATION;
D O I
10.3390/en10111732
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Information technology (IT) has brought significant changes in people's lives. As an important part of the IT industry, data centres (DCs) have been rapidly growing in both the number and size over the past 40 years. Around 30% to 40% of electricity consumption in DCs is used for space cooling, thus leading to very inefficient DC operation. To identify ways to reduce the energy consumption for space cooling and increase the energy efficiency of DCs' operation, a dedicated investigation into the energy usage in DCs has been undertaken and a novel high performance dew point cooling system was introduced into a DC operational scheme. Based on the cooling load in DCs, a case study was carried out to evaluate the energy consumptions and energy usage effectiveness when using the novel dew point cooling system in different scales of DCs in various climates. It was found that by using the novel dew point cooling system, for 10 typical climates a DC can have a much lower power usage effectiveness (PUE) of 1.10 to 1.22 compared to that of 1.7 to 3.7 by using existing traditional cooling systems, leading to significantly increased energy efficiency of the DC operation. In addition, the energy performance by managing the cooling air supply at the different levels in DCs, i.e., room, row and rack level, was simulated by using a dynamic computer model. It was found that cooling air supply at rack level can provide a higher energy efficiency in DCs. Based on the above work, the energy saving potential in DCs was conducted by comparing DCs using an the novel dew point cooling system and the optimum management scheme for the cooling air supply to that using traditional air cooling systems and the same supply air management. Annual electricity consumptions for the two cases were given. It was found that by using the novel dew point cooling system and optimum management system for the cooling air supply, an 87.7-91.6% electricity consumption saving for space cooling in DCs could be achieved in 10 typical cities at 10 selected climatic conditions.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Application Potential of a Dew-Point Cooling Tower in Selected Energy Intensive Applications in Temperate Climate
    Pandelidis, Demis
    Matuszczak, Mikolaj
    Krowicki, Pawel
    Poskart, Bartosz
    Iskierka, Grzegorz
    Worek, William
    Cetin, Sabri
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [22] Numerical investigation of the energy performance of a guideless irregular heat and mass exchanger with corrugated heat transfer surface for dew point cooling
    Xu, Peng
    Ma, Xiaoli
    Diallo, Thierno M. O.
    Zhao, Xudong
    Fancey, Kevin
    Li, Deying
    Chen, Hongbing
    ENERGY, 2016, 109 : 803 - 817
  • [23] Energy saving evaluation of a novel energy system based on spray cooling for supercomputer center
    Chen, Hua
    Cheng, Wen-long
    Zhang, Wei-wei
    Peng, Yu-hang
    Jiang, Li-jia
    ENERGY, 2017, 141 : 304 - 315
  • [24] Energy saving potential of heat removal using natural cooling water in the top zone of buildings with large interior spaces
    Liang, Chao
    Shao, Xiaoliang
    Li, Xianting
    BUILDING AND ENVIRONMENT, 2017, 124 : 323 - 335
  • [25] Simulation of energy saving potential of a centralized HVAC system in an academic building using adaptive cooling technique
    Bhaskoro, Petrus Tri
    Gilani, Syed Ihtsham Ul Haq
    Aris, Mohd Shiraz
    ENERGY CONVERSION AND MANAGEMENT, 2013, 75 : 617 - 628
  • [26] Performance and Economical Analyses of a Dew Point Evaporative Cooling System Using Stepwise Regression Approach
    Sohani, Ali
    Hasani-Balyani, Hamidreza
    Sayyaadi, Hoseyn
    Maisotsenko, Valeriy
    2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [27] Experimental Investigation of an Energy Saving System Using Phase Change Materials in buildings
    El-Ghetany, H. H.
    Aly, Wael I. A.
    Shalata, Hany A.
    Eid, A. I.
    Abdelwahed, Khaled
    EGYPTIAN JOURNAL OF CHEMISTRY, 2020, 63 (11): : 4533 - 4544
  • [28] Numerical study of a novel counter-flow heat and mass exchanger for dew point evaporative cooling
    Zhao, X.
    Li, J. M.
    Riffat, S. B.
    APPLIED THERMAL ENGINEERING, 2008, 28 (14-15) : 1942 - 1951
  • [29] Integrated cooling system with multiple operating modes for temperature control of energy storage containers: Experimental insights into energy saving potential
    Wang, Ningbo
    Wei, Zuyuan
    Tian, Bo
    Wang, Fei
    Shao, Shuangquan
    ENERGY, 2025, 321
  • [30] Energy-saving potential of a radiant cooling system in different climate zones of India
    Khan, Yasin
    Bhandari, Mahabir
    Mathur, Jyotirmay
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2018, 24 (04) : 356 - 370