Shear bond strength of rebonded brackets after removal of adhesives with Er,Cr:YSGG laser

被引:20
作者
Ishida, Katsuyuki [1 ]
Endo, Toshiya [1 ]
Shinkai, Koichi [2 ]
Katoh, Yoshiroh [2 ]
机构
[1] Nippon Dent Univ, Niigata Hosp, Chuo Ku, Niigata 9518580, Japan
[2] Nippon Dent Univ, Sch Life Dent Niigata, Dept Operat Dent, Niigata 9518580, Japan
关键词
Er; Cr:YSGG Laser; Recycled brackets; Shear bond strength; Adhesive remnant index; SELF-ETCHING PRIMER; SALIVA CONTAMINATION; CERAMIC BRACKETS; CLINICAL-TRIAL; BASE DESIGN; IN-VITRO; FAILURE; ENAMEL;
D O I
10.1007/s10266-011-0012-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study was conducted to examine the bond strength of rebonded orthodontic brackets after adhesive residuals on the surface of the bracket bases were removed by Er,Cr:YSGG lasers. Seventy-six brackets bonded to premolars with a self-etching primer adhesive system were equally divided into four groups after the first debonding with the bracket bases (Group 1) untreated, and treated by (Group 2) Er,Cr:YSGG laser, (Group 3) sandblaster, and (Group 4) Er,Cr:YSGG laser/sandblaster. The treated brackets were rebonded to the new premolars in the same manner as the first-stage experiment. The shear bond strengths were measured, with the bonding/debonding procedures repeated once after the first debonding, and the bracket/adhesive failure modes were evaluated after each debonding. The treated bracket base surfaces were observed under a scanning electron microscopy (SEM). The mean rebond strengths were significantly lower in group 1 than in other groups, and there were no significant differences between the other groups. The mean initial bond strength was significantly higher than the mean rebond strength in group 1 but there was no significant difference between the two in the other three groups. Failures at the bracket-adhesive interface occurred frequently at second debonding in group 1. Under the SEM, residual adhesive was removed from the bracket bases by Er,Cr:YSGG laser, while adhesive remnant was seen underneath the meshwork of the bracket bases and microroughness appeared on the meshwork after sandblasting. Er,Cr:YSGG laser certainly could serve the purpose of promoting the use of recycled orthodontic brackets.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 25 条
[1]   Effects of tooth bleaching on shear bond strength of brackets rebonded with a self-etching adhesive system [J].
Abe, Ryota ;
Endo, Toshiya ;
Shimooka, Shohachi .
ODONTOLOGY, 2011, 99 (01) :83-87
[2]  
Almeida H C, 2009, Int J Orthod Milwaukee, V20, P9
[3]  
ALTMAN DG, 1991, PRACTICAL STAT MED R, P401
[4]   Effects of sandblasting metal bracket base on the bond strength of a resin-modified glass ionomer cement:: an in vitro study [J].
Arici, S ;
Ozer, M ;
Arici, N ;
Gencer, Y .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2006, 17 (03) :253-258
[5]   CLINICAL-TRIALS WITH CRYSTAL-GROWTH CONDITIONING AS AN ALTERNATIVE TO ACID-ETCH ENAMEL PRETREATMENT [J].
ARTUN, J ;
BERGLAND, S .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1984, 85 (04) :333-340
[6]  
Basudan A M, 2001, J Orthod, V28, P231, DOI 10.1093/ortho/28.3.231
[7]   Effect of saliva contamination on bracket failure with a self-etching primer: A prospective controlled clinical trial [J].
Campoy, Maria D. ;
Plasencia, Eliseo ;
Vicente, Ascension ;
Bravo, Luis A. ;
Cibrian, Rosa .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (05) :679-683
[8]   Shear bond strength of rebonded mechanically retentive ceramic brackets [J].
Chung, CH ;
Friedman, SD ;
Mante, FK .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 122 (03) :282-287
[9]  
De Moor RJG, 2009, J ADHES DENT, V11, P427, DOI [10.3290/j.jad.a18136, 10.3290/j.jad.a17528]
[10]   Bond strength of rebonded orthodontic brackets [J].
Egan, FR ;
Alexander, SA ;
Cartwright, GE .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1996, 109 (01) :64-70