Light emitting diode assessment of dentinal microcracks after root canal preparation with 4 different heat-treated file systems

被引:0
|
作者
Pandey, Sanket H. [1 ]
Patni, Pallav M. [1 ]
Jain, Pradeep [1 ]
Raghuwanshi, Swadhin [1 ]
Sanwatsarkar, Gauri [1 ]
Chaturvedi, Arpita [1 ]
机构
[1] Madhya Pradesh Med Sci Univ, Dept Conservat Dent & Endodont, Sri Aurobindo Coll Dent, Kanadia Rd, Indore, India
关键词
Molar; Mandible; Root canal preparation; CYCLIC FATIGUE RESISTANCE; ROTARY INSTRUMENTS; WAVEONE GOLD; RECIPROC; PROTAPER; DEFECTS; MOTION;
D O I
10.23736/S2724-6329.21.04523-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BACKGROUND: The purpose of this research was to evaluate the dentinal microcracks formation after root canal prepa-ration with Hyflex (R) EDM ([electrical discharge machining], Coltene; Altstatten, Switzerland), Neolix Neoniti A1 EDM (Neolix; Beijing, China), Wave One Gold (Dentsply Sirona; York, PA, USA) and Edge File (R) X1 (EdgeEndo; Albuquer-que, NM, USA) under illumination and magnification. METHODS: One hundred fifty mandibular molars with 2 different mesial canals extracted for periodontal reasons were included in the study. The samples were decoronated at 15 mm from the apex using a carborundum disc under copious water cooling. Access opening was done using a round bur. Sectioning of the distal root was done. Patency of mesial canals were checked using a 10 K file. The samples were randomly divided into 5 groups using simple randomization technique: group 1 (uninstrumented group); group 2 (Hyflex (R) EDM [HEDM] [Coltene]); group 3 (Neolix Neoniti A1 [NA1] [Neolix]); group 4 (Wave One Gold [WOG] [Dentsply Sirona]); and group 5 (Edge File (R) X1 [EFX] [EdgeEndo]). Biomechanical preparation in all groups was done following the manufacturer's instructions. Sectioning was done at 3 mm, 6 mm, and 9 mm from the apex using a 0.13 mm circular saw under copious water cooling. Sections were observed at 16x magnification under the dental operating microscope and illumination using a light emitting diode (LED) curing light. The chi(2) test was used to determine the statistically significant differences at P<0.05. Intergroup comparison was done by the post-hoc Tukey test. RESULTS: Total of 1800 images were analyzed. The highest number of cracks was seen in Neoniti A1 group (43.33%) while the least number of cracks were seen with Wave One Gold group (13.33%). There was statistically difference be-tween reciprocating groups and the rotary group. CONCLUSIONS: Within the limitations of this study, it can be concluded that all the heat-treated file systems produced dentinal microcracks. Rotary group (NA1 and HEDM) produced significantly more cracks than reciprocation group (WOG and EFX).
引用
收藏
页码:257 / 262
页数:6
相关论文
共 29 条
  • [21] Comparison of apical debris extrusion during root canal preparation in primary molars using different file systems: an in vitro study
    Mohammadi, Davood
    Mehran, Majid
    Frankenberger, Roland
    BabeveyNejad, Newsha
    Banakar, Morteza
    Haghgoo, Roza
    AUSTRALIAN ENDODONTIC JOURNAL, 2022, 48 (03) : 473 - 480
  • [22] Comparison of root canal shaping ability of different heat-treated NiTi single files: a micro-CT study
    Bal, Emine Zeynep
    Gunes, Betul
    Bayrakdar, Ibrahim Sevki
    QUINTESSENCE INTERNATIONAL, 2022, 53 (02): : 112 - 121
  • [23] Assessment of postoperative pain after single-visit root canal treatment using rotary and reciprocating file systems: an in vivo study
    Shaik, Reshma Parveen
    Chukka, Ram Sunil
    Bandlapally, Anila
    Vemuri, Sayesh
    Bolla, Nagesh
    Basam, Ram Chowdary
    Tammineedi, Sravanthi
    JOURNAL OF DENTAL ANESTHESIA AND PAIN MEDICINE, 2022, 22 (04) : 267 - 275
  • [24] Influence of optimum torque reverse motion on dentinal cracks after root canal preparation with two nickel-titanium rotary systems
    Khallaf, Maram
    Hassan, Reham
    CONTEMPORARY CLINICAL DENTISTRY, 2022, 13 (02) : 183 - 188
  • [25] Assessment of the Apical Transportation and Quantity of Root Canal Dentin Removed Using Different New Rotary File Systems: An Original Study
    Singh, Harmeet
    Shukla, Anuj K.
    Jadhav, Apurva A.
    Shetty, Anshuman
    Shetty, Chitharanjan
    Dutta, Smita D.
    Mustafa, Mohammed
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S141 - S145
  • [26] Comparative Evaluation of Dentinal Microcrack Formation before and after Root Canal Preparation Using Rotary, Reciprocating, and Adaptive Instruments at Different Working Lengths-A Micro- computed Tomographic Study
    Aggarwal, Arunima
    Nawal, Ruchika Roongta
    Yadav, Seema
    Talwar, Sangeeta
    Kunnoth, Sriram
    Mahajan, Puneet
    JOURNAL OF ENDODONTICS, 2021, 47 (08) : 1314 - 1320
  • [27] Pain after single-visit root canal treatment with two single-file systems based on different kinematics—a prospective randomized multicenter clinical study
    Prasanna Neelakantan
    Subash Sharma
    Clinical Oral Investigations, 2015, 19 : 2211 - 2217
  • [28] Pain after single-visit root canal treatment with two single-file systems based on different kinematics-a prospective randomized multicenter clinical study
    Neelakantan, Prasanna
    Sharma, Subash
    CLINICAL ORAL INVESTIGATIONS, 2015, 19 (09) : 2211 - 2217
  • [29] Substance P/calcitonin gene-related peptide and their receptors expression in human periodontal ligament after root canal preparation with five different systems
    Caviedes-Bucheli, Javier
    Munoz-Alvear, Hernan Dario
    Lopez-Moncayo, Luis Fernando
    Kacharaju, Kranthi Raja
    Velasquez-Rivera, Adriana Carolina
    Carlosama-Recalde, Luis Alberto
    Pazmino, Juan Camilo
    Gomez-Sosa, Jose Francisco
    Diaz-Barrera, Luis Eduardo
    Munoz, Hugo Roberto
    INTERNATIONAL ENDODONTIC JOURNAL, 2024, 57 (05) : 576 - 585