Multicenter evaluation of the bovine mesenteric vein bioprostheses for Hemodialysis access in patients with an earlier failed prosthetic graft

被引:63
作者
Katzman, HE
Glickman, MH
Schild, AF
Fujitani, RM
Lawson, JH
机构
[1] Duke Univ, Med Ctr, Dept Surg, Durham, NC 27710 USA
[2] Cedars Sinai Med Ctr, Miami, FL USA
[3] Eastern Virginia Med Sch, Norfolk, VA 23501 USA
[4] Univ Miami, Sch Med, Miami, FL USA
[5] Univ Calif Irvine, Med Ctr, Irvine, CA USA
关键词
D O I
10.1016/j.jamcollsurg.2005.03.040
中图分类号
R61 [外科手术学];
学科分类号
摘要
BACKGROUND: The number of patients requiring hemodialysis increases each year, with a large cohort of patients still requiring prosthetic grafts for hemodialysis. All available prosthetic vascular access grafts have predictable failure rates, leading to a large group of patients with multiple failed access grafts. This report evaluates use of mesenteric vein bioprosthesis (MVB) as a conduit for patients who have failed at least one earlier synthetic vascular access graft. STUDY DESIGN: Two-hundred seventy-six access grafts were implanted in patients who had at least one earlier failed synthetic graft. Of these grafts, 183 were MVB and 93 were synthetic. Graft histories were obtained from 128 of the 183 patients who received the MVB, representing a nonrandomized historic data set of previously failed grafts as an internal control group (INT). Patency was determined by Kaplan-Meier analysis, and the Cox proportional hazards model was used for multivariate analysis of factors predictive of effect. RESULTS: Primary patency at 12 months was 35.6% MVB versus 28.4% synthetic grafts. At 24 months, secondary patency was 60.3% MVB, 42.9% synthetic, and 18.0% INT (p < 0.0001, log-rank). Complication rates, including dilation, seroma, infection, and thrombosis, were all notably lower for the MVB compared with synthetic grafts by Cox regression (p < 0.001). Intervention rate per patient year was lower in the MVB group (0.97 versus 1.37) compared with synthetic grafts (p = 0.003). CONCLUSIONS: MVB provided superior secondary graft patency compared with both historic graft data or newly implanted nonrandomized synthetic implants. A considerable reduction in thrombosis, infection, and interventions was observed with the MVB graft. These results Suggest that MVB offers a safe alternative to patients who have a history of failing synthetic access grafts and may represent an option for extending vascular access to this patient population.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 21 条
[1]   Changes in the practice of angioaccess surgery: Impact of dialysis outcome and quality initiative recommendations [J].
Ascher, E ;
Gade, P ;
Hingorani, A ;
Mazzariol, F ;
Gunduz, Y ;
Fodera, M ;
Yarkovich, W .
JOURNAL OF VASCULAR SURGERY, 2000, 31 (01) :84-90
[2]   Survival of prosthetic crafts of different materials after impairment of a native arteriovenous fistula in hemodialysis patients [J].
Bacchini, G ;
Del Vecchio, L ;
Andrulli, S ;
Pontoriero, G ;
Locatelli, F .
ASAIO JOURNAL, 2001, 47 (01) :30-33
[3]   Impact of secondary procedures in autogenous arteriovenous fistula maturation and maintenance - Discussion [J].
Lumsden, AB ;
Berman, SS ;
Gloviczki, P .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (05) :870-871
[4]   The use of cryopreserved femoral vein grafts for hemodialysis access in patients at high risk for infection: A word of caution - Discussion [J].
Matsuura, J ;
Bolton, WD ;
Kiell, C ;
Lumsden, A .
JOURNAL OF VASCULAR SURGERY, 2002, 36 (03) :467-468
[5]  
DARDIK H, 1984, ANN SURG, V1, P161
[6]  
*DOQI, 2001, AM J KIDNEY DIS S, V37, pS137
[7]   Vascular access survival and incidence of revisions: A comparison of prosthetic grafts, simple autogenous fistulas, and venous transposition fistulas from the United States Renal Data System Dialysis Morbidity and Mortality Study [J].
Gibson, KD ;
Gillen, DL ;
Caps, MT ;
Kohler, TR ;
Sherrard, DJ ;
Stehman-Breen, CO .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (04) :694-700
[8]   Assessment of a policy to reduce placement of prosthetic hemodialysis access [J].
Gibson, KD ;
Caps, MT ;
Kohler, TR ;
Hatsukami, TS ;
Gillen, DL ;
Aldassy, M ;
Sherrard, DJ ;
Stehman-Breen, CO .
KIDNEY INTERNATIONAL, 2001, 59 (06) :2335-2345
[9]   Multicenter evaluation of a polyurethaneurea vascular access graft as compared with the expanded polytetrafluoroethylene vascular access graft in hemodialysis applications [J].
Glickman, MH ;
Stokes, GK ;
Ross, JR ;
Schuman, ED ;
Sternbergh, WC ;
Lindberg, JS ;
Money, SM ;
Lorber, MI .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (03) :465-472
[10]  
Gray R, 1998, J VASC SURG, V27, P392