摘要
Fiber-reinforced polymers (FRP) can provide a strengthening alternative for unreinforced and under-reinforced masonry. The case with which FRP can be installed on the exterior of a masonry wall makes this form of strengthening attractive to the owner, considering both reduced installation cost and down time of the occupied structure. Six unreinforced concrete masonry walls (four at 1.8 m tall and two at 4.7 m tall) were tested in out-of-plane flexure up to capacity. The walls were strengthened with glass FRP composite composed of unidirectional E-glass fabric with an epoxy matrix. The composite was adhered to the surface of the masonry using the same epoxy with the fibers oriented perpendicular to the bed joints. General flexural strength design equations are presented and compared with the results of the testing. It was found that the equations overpredicted the actual capacity of the test specimens by no more than 20%.
引用
收藏
页码:170 / 178
页数:9
相关论文
共 16 条
[1]  
ALBERT ML, 1998, 225 U ALB DEP CIV EN
[2]  
[Anonymous], 1994, EARTHQ SPECTRA
[3]  
[Anonymous], EARTHQUAKE SPEC
[4]  
BADGER CCR, 1997, THESIS U WYOMING LAR
[5]  
CHRISTENSEN JB, 1996, J ARCHIT ENG, V2, P63
[6]  
EHSANI M, 1996, TMS J, V14, P63
[7]  
EHSANI MR, 1999, J COMPOS CONSTR, V3, P134, DOI DOI 10.1061/(ASCE)1090-0268(1999)3:3(134)
[8]   SEISMIC RESPONSE AND RETROFIT OF INDUSTRIAL BRICK MASONRY CHIMNEYS [J].
GHOBARAH, A ;
BAUMBER, T .
CANADIAN JOURNAL OF CIVIL ENGINEERING, 1992, 19 (01) :117-128
[9]   Out-of-plane bending of FRP-reinforced masonry walls [J].
Gilstrap, JM ;
Dolan, CW .
COMPOSITES SCIENCE AND TECHNOLOGY, 1998, 58 (08) :1277-1284
[10]  
HAMILTON HR, 1999, P 4 INT S FIB REINF