Performance analysis of solar thermal system for heating of a detached house in harsh cold region of Mongolia

被引:16
作者
Erdenedavaa, Purevdalai [1 ]
Adiyabat, Amarbayar [2 ]
Akisawa, Atsushi [1 ]
Otgonjanchiv, Erdenesuvd [2 ]
机构
[1] Tokyo Univ Agr & Technol, Grad Sch Bio Applicat & Syst Engn, Fuchu, Tokyo 183, Japan
[2] Natl Univ Mongolia, Sch Engn & Appl Sci, Ulaanbaatar, Mongolia
关键词
Evacuated tube solar collector; Harsh cold and dry climate; Simple detached house; Heating; Efficiency and Ulaanbaatar; PIPE EVACUATED TUBE; FLAT-PLATE; COLLECTORS; ULAANBAATAR; POLLUTION;
D O I
10.1016/j.renene.2017.10.042
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ulaanbaatar is one of the top five cities with worst air quality because of the use of raw coal in the Ger District. The objective of this paper is to analyze the environmental significance of solar heating system with triple heat sources including the solar collector, coal stove, and electric heater for a simple detached house in the harsh cold and dry climate. A long-term measurement was conducted in a Ger district of Ulaanbaatar city, Mongolia. Based on the measurement of the solar thermal system for 8 months, from October 2015 to May 2016, it was found that the average collector efficiency was 49.8% and system efficiency was 37%. The study also reported monthly performance of the system. The dust deposition on the glass tubes of the evacuated tube solar collector considerably decreased the performance, especially during winter season. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:217 / 226
页数:10
相关论文
共 38 条
[1]   An assessment of air pollution and its attributable mortality in Ulaanbaatar, Mongolia [J].
Allen, Ryan W. ;
Gombojav, Enkhjargal ;
Barkhasragchaa, Baldorj ;
Byambaa, Tsogtbaatar ;
Lkhasuren, Oyuntogos ;
Amram, Ofer ;
Takaro, Tim K. ;
Janes, Craig R. .
AIR QUALITY ATMOSPHERE AND HEALTH, 2013, 6 (01) :137-150
[2]  
[Anonymous], 2018, Technical Report, World Health Organization, Version 2
[3]  
[Anonymous], 2013, FULL REP MONG UL
[4]  
[Anonymous], 2011, FRONT HEAT PIPES FHP
[5]   Thermal performance analysis of a solar water heating system with heat pipe evacuated tube collector using data from a field trial [J].
Ayompe, L. M. ;
Duffy, A. .
SOLAR ENERGY, 2013, 90 :17-28
[6]   Theoretical and experimental investigation of heat pipe solar collector [J].
Azad, E. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2008, 32 (08) :1666-1672
[7]   Assessment of three types of heat pipe solar collectors [J].
Azad, E. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (05) :2833-2838
[8]   Control optimization through simulations of large scale solar plants for industrial heat applications [J].
Ben Hassine, Ilyes ;
Sehgelmeble, Mariela Cotrado ;
Soell, Robert ;
Pietruschka, Dirk .
INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY, SHC 2014, 2015, 70 :595-604
[9]   Thermal Performance Testing of Heat Pipe Evacuated Tube with Compound Parabolic Concentrating Solar Collector by ISO 9806-1 [J].
Chamsa-ard, Wisut ;
Sukchai, Sukruedee ;
Sonsaree, Sorawit ;
Sirisamphanwong, Chatchai .
11TH ECO-ENERGY AND MATERIALS SCIENCE AND ENGINEERING (11TH EMSES), 2014, 56 :237-246
[10]   An experimental study of the utilization of heat pipes for solar water heaters [J].
Chun, W ;
Kang, YH ;
Kwak, HY ;
Lee, YS .
APPLIED THERMAL ENGINEERING, 1999, 19 (08) :807-817