Biosensor for direct cell detection, quantification and analysis

被引:18
作者
Cortes, Sandra [2 ]
Villiers, Christian L. [2 ]
Colpo, Pascal [3 ]
Couderc, Rachel [2 ]
Brakha, Carine [2 ]
Rossi, Francois [3 ]
Marche, Patrice N. [2 ]
Villiers, Marie-Bernadette [1 ,2 ]
机构
[1] Inst Albert Bonniot, INSERM, U823, F-38042 Grenoble 9, France
[2] Univ Grenoble 1, UMR S823, F-38042 Grenoble, France
[3] European Commiss Joint Res Ctr, Ispra, VA, Italy
关键词
Surface plasmon resonance imaging; Cell; Antibody; Polyethylene oxide; Biological samples; Receptor; SURFACE-PLASMON RESONANCE; LIVING CELLS; REAL-TIME; ANTIBODY; RECEPTOR; BINDING; LYMPHOCYTES; MICROARRAYS; INFECTION; IGG;
D O I
10.1016/j.bios.2011.04.016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Microarrays are promising tools for cell isolation and detection. However, they have yet to be widely applied in biology. This stems from a lack of demonstration of their sensitivity and compatibility with complex biological samples, and a lack of proof that their use does not induce aberrant cellular effects. Herein, we characterized and optimized a recently developed technology associating antibody microarrays with surface plasmon resonance imaging (SPRi). Using a murine macrophage cell line we demonstrate the binding specificity of our antibody-microarrays and the correlation between SPRi signals and both the number of bound cells, and the level of expression of cell surface markers. Confocal microscopy reveals that cell binding to the chip through antibody-antigen interactions underwent morphological changes reflecting the density of the relevant cell surface marker without affecting cell viability as shown by fluorescent microscopy. The detection threshold of the microarray-SPRi system is lowered 10-fold by applying a polyethylene oxide film to the gold surface of the chip. This increased sensitivity allows the detection of cells representing as little as 0.5% of a mixed population. The potential of this method is illustrated by two applications: characterization of ligand-cell receptor interactions, allowing determination of receptor specificity, and analysis of peripheral blood mononuclear cells, demonstrating the suitability of this tool for the analysis of complex biological samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4162 / 4168
页数:7
相关论文
共 29 条
[1]   Immortalized myeloid suppressor cells trigger apoptosis in antigen-activated T lymphocytes [J].
Apolloni, E ;
Bronte, V ;
Mazzoni, A ;
Serafini, P ;
Cabrelle, A ;
Segal, DM ;
Young, HA ;
Zanovello, P .
JOURNAL OF IMMUNOLOGY, 2000, 165 (12) :6723-6730
[2]   Fouling and non-fouling surfaces produced by plasma polymerization of ethylene oxide monomer [J].
Brétagnol, F ;
Lejeune, M ;
Papadopoulou-Bouraoui, A ;
Hasiwa, M ;
Rauscher, H ;
Ceccone, G ;
Colpo, P ;
Rossi, F .
ACTA BIOMATERIALIA, 2006, 2 (02) :165-172
[3]  
Canetta E, 2005, BIORHEOLOGY, V42, P321
[4]   Fabrication and characterization of protein arrays for stem cell patterning [J].
Ceriotti, Laura ;
Buzanska, Leonora ;
Rauscher, Hubert ;
Mannelli, Ilaria ;
Sirghi, Lucel ;
Gilliland, Douglas ;
Hasiwa, Marina ;
Bretagnol, Frederic ;
Zychowicz, M. ;
Ruiz, Ana ;
Bremer, Susanne ;
Coecke, Sandra ;
Colpo, Pascal ;
Rossi, Francois .
SOFT MATTER, 2009, 5 (07) :1406-1416
[5]   Marked differences in human melanoma antigen-specific T cell responsiveness after vaccination using a functional microarray [J].
Chen, DS ;
Soen, Y ;
Stuge, TB ;
Lee, PP ;
Weber, JS ;
Brown, PO ;
Davis, MM .
PLOS MEDICINE, 2005, 2 (10) :1018-1030
[6]   Clinically related protein-peptide interactions monitored in real time on novel peptide chips by surface plasmon resonance imaging [J].
Cherif, B ;
Roget, A ;
Villiers, CL ;
Calemczuk, R ;
Leroy, V ;
Marche, PN ;
Livache, T ;
Villiers, MB .
CLINICAL CHEMISTRY, 2006, 52 (02) :255-262
[7]  
Dörries R, 2001, CURR TOP MICROBIOL, V253, P219
[8]   A High-Throughput Ligand Competition Binding Assay for the Androgen Receptor and Other Nuclear Receptors [J].
Feau, Clementine ;
Arnold, Leggy A. ;
Kosinski, Aaron ;
Guy, R. Kiplin .
JOURNAL OF BIOMOLECULAR SCREENING, 2009, 14 (01) :43-48
[9]   A polypyrrole protein microarray for antibody-antigen interaction studies using a label-free detection process [J].
Grosjean, L ;
Cherif, B ;
Mercey, E ;
Roget, A ;
Levy, Y ;
Marche, PN ;
Villiers, MB ;
Livache, T .
ANALYTICAL BIOCHEMISTRY, 2005, 347 (02) :193-200
[10]   RECEPTORS FOR IGG - SUBCLASS SPECIFICITY OF RECEPTORS ON DIFFERENT MOUSE CELL-TYPES AND DEFINITION OF 2 DISTINCT RECEPTORS ON A MACROPHAGE CELL LINE [J].
HEUSSER, CH ;
ANDERSON, CL ;
GREY, HM .
JOURNAL OF EXPERIMENTAL MEDICINE, 1977, 145 (05) :1316-1327