Evaluation of sidewall air supply with the stratified indoor environment in a consultation room

被引:17
|
作者
Tian, Xue [1 ]
Cheng, Yong [2 ,3 ]
Liu, Jian [1 ]
Lin, Zhang [4 ,5 ]
机构
[1] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Peoples R China
[2] Chongqing Univ, Minist Educ, Joint Int Res Lab Green Bldg & Built Environm, Chongqing, Peoples R China
[3] Chongqing Univ, Sch Civil Engn, Chongqing, Peoples R China
[4] City Univ Hong Kong, Div Bldg Sci & Technol, Hong Kong, Peoples R China
[5] City Univ Hong Kong, Shenzhen Res Inst, Shenzhen, Peoples R China
基金
中国国家自然科学基金;
关键词
Sidewall air supply; Displacement ventilation; Stratum ventilation; Energy utilization coefficient; Contaminant removal efficiency; THERMAL COMFORT; STRATUM VENTILATION; DISPLACEMENT VENTILATION; PERFORMANCE EVALUATION; DISTRIBUTION SYSTEMS; PIV MEASUREMENTS; FLOW; QUALITY; EFFICIENCY; LOCATION;
D O I
10.1016/j.scs.2021.103328
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To take advantage of both stratum ventilation and displacement ventilation, while breaking some of their limitations, the sidewall air supply is introduced. Computational fluid dynamics simulations of 16 cases are conducted, to assess the application of the sidewall air supply in a consultation room, referring to thermal comfort, indoor air quality and energy utilization. Two supply air terminal layouts of the sidewall air supply (i.e., singleside supply and double-side supply), four supply air temperatures within 20-26 degrees C, and five air change rates within 2.9-14.7 air changes per hour are applied. The results indicate that the sidewall air supply can provide satisfactory thermal comfort levels up to Category A in ISO 7730, with proper design. Using double-side supply reduces the draft rate by up to 25%, and improves the energy utilization coefficient and contaminant removal efficiency by up to 3.3 and 1.83, compared with the single-side supply. Additionally, for the single-side supply which achieves stratum ventilation, the closer the supply air jet center to the breathing zone, the higher the energy utilization coefficient and contaminant removal efficiency at the breathing zone are. Finally, the energy utilization coefficient and contaminant removal efficiency show a positive relationship for the sidewall air supply. This may be valid for the air distribution methods that provide stratified indoor environments. This study expands the application scenario of displacement ventilation and stratum ventilation, guides to obtain the best thermal comfort, energy utilization and contaminant removal performances simultaneously, while saving the measuring costs of indoor air quality.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Indoor Air Stratification in Warm Air Supply Systems
    Prozuments, Aleksejs
    Borodinecs, Anatolijs
    ASHRAE JOURNAL, 2017, 59 (11) : 54 - 65
  • [32] A TOPSIS optimization for the indoor thermal environment through oscillating airflow generated from a cassette split type air conditioner
    Fan, Yunqing
    INDOOR AND BUILT ENVIRONMENT, 2021, 30 (08) : 1200 - 1210
  • [33] CFD simulation of stratified indoor environment in displacement ventilation: Validation and sensitivity analysis
    Gilani, Sara
    Montazeri, Hamid
    Blocken, Bert
    BUILDING AND ENVIRONMENT, 2016, 95 : 299 - 313
  • [34] Comparison of air-conditioning systems with bottom-supply and side-supply modes in a typical office room
    Zheng, Chenxiao
    You, Shijun
    Zhang, Huan
    Zheng, Wandong
    Zheng, Xuejing
    Ye, Tianzheng
    Liu, Zeqin
    APPLIED ENERGY, 2018, 227 : 304 - 311
  • [35] Experimental evaluation of an intermittent air supply system Part 2: Occupant perception of thermal climate
    Kabanshi, Alan
    Wigo, Hans
    Ljung, Robert
    Sorqvist, Patrik
    BUILDING AND ENVIRONMENT, 2016, 108 : 99 - 109
  • [36] Experimental evaluation of thermal comfort, ventilation performance indices and exposure to airborne contaminant in an airborne infection isolation room equipped with a displacement air distribution system
    Berlanga, F. A.
    Ruiz de Adana, M.
    Olmedo, I.
    Villafruela, J. M.
    San Jose, J. F.
    Castro, F.
    ENERGY AND BUILDINGS, 2018, 158 : 209 - 221
  • [37] Uniformity of Supply Air in the Plenum for Under-Floor Air Distribution Ventilation in a Circular Conference Room: A CFD Study
    Fan, Xiaolei
    Yu, Tao
    Liu, Peng
    Li, Xiangdong
    ENERGIES, 2022, 15 (17)
  • [38] Influence of sensible cooling load on indoor air distribution in an office room with ceiling cooling and mixing ventilation
    Wu, Xiaozhou
    Wang, Haichao
    Gao, Jie
    Wang, Fenghao
    INDOOR AND BUILT ENVIRONMENT, 2021, 30 (07) : 957 - 969
  • [39] IMPACT OF VENTILATION SYSTEM TYPE ON INDOOR THERMAL ENVIRONMENT AND HUMAN THERMAL COMFORT IN A CEILING COOLING ROOM
    Wu, Xiaozhou
    Liu, Genglin
    Gao, Jie
    Wu, Shuang
    THERMAL SCIENCE, 2022, 26 (4B): : 3271 - 3284
  • [40] Performance evaluation of an air conditioning system with different heights of supply outlet applied to a sleeping environment
    Mao Ning
    Pan Dongmei
    Chan Mingyin
    Deng Shiming
    ENERGY AND BUILDINGS, 2014, 77 : 281 - 291