Incomplete charge collection in an HPGe double-sided strip detector

被引:16
|
作者
Hayward, Jason [1 ]
Wehe, David [2 ]
机构
[1] Univ Tennessee, Dept Nucl Engn, Knoxville, TN 37996 USA
[2] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
Compton imaging; HPGe detector; double-sided strip detector; charge loss; strip gap; inter-strip position interpolation; charge-carrier cloud;
D O I
10.1016/j.nima.2007.12.013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For gamma-ray detection, high-purity germanium (HPGe) has long been the standard for energy resolution, and double-sided strip detectors (DSSDs) offer the possibility of sub-millimeter position resolution. Our HPGe DSSD is 81 mm in diameter, 11-mm thick, and has 3-mm strip pitch with a gap width of 500 mu m. In this work, we focus on characterizing just the interactions that occur between collecting strips. Simulation and measurement results for our HPGe DSSD show that the gap between strips is the most position-sensitive region. But, spectra collected from events that occur in and near the gaps are complicated by: (1) incomplete charge-carrier collection, or charge loss; (2) signal variance introduced by charge-carrier cloud size, orientation, and lateral spreading; and (3) the difficulty of distinguishing single interactions from multiple close interactions. Using tightly, collimated beams of monoenergetic gamma rays, the measured energy spectra at the gap center show that incomplete charge collection is significant in our detector at 356 and 662 keV, resulting in degradation of the photopeak efficiency. Additionally, close interactions are identifiable in the spectra. Thus, close interactions must be identified on an event-by-event basis in order to precisely identify gap interaction position or make charge-loss corrections at these energies. Furthermore, spectral differences are observed between anode and cathode gaps, and a possible reason for this asymmetry is proposed. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 223
页数:9
相关论文
共 50 条
  • [41] Charge collection studies of heavily irradiated 3D Double-Sided sensors
    Bates, Richard L.
    Parkes, C.
    Pennicard, D.
    Rakotomiaramanana, B.
    Fleta, C.
    Pellegrini, G.
    Lozano, M.
    Parzefall, U.
    Blot, X.
    Haerkoenen, J.
    Tuovinen, E.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 148 - +
  • [42] RADIATION EFFECTS OF DOUBLE-SIDED SILICON STRIP SENSORS
    TAMURA, N
    HATAKENAKA, T
    IWATA, Y
    KUBOTA, M
    OHSUGI, T
    OKADA, M
    UNNO, Y
    ASO, T
    ISHIZUKA, M
    MIYATA, H
    ANDO, A
    HATANAKA, K
    MIZUNO, Y
    GOTO, M
    KOBAYASHI, S
    MURAKAMI, A
    INOUE, K
    SUZUKI, Y
    DAIGO, M
    YAMAMOTO, K
    YAMAMURA, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 342 (01): : 131 - 136
  • [43] SIGNAL SIMULATIONS FOR DOUBLE-SIDED SILICON STRIP DETECTORS
    LESLIE, J
    SEIDEN, A
    UNNO, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 557 - 562
  • [44] Development of double-sided silicon strip position sensor
    Park, H.
    Do, S. H.
    Kah, D. H.
    Kang, H. D.
    Kim, D. S.
    Kim, H. J.
    Shim, D. H.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 781 - 785
  • [45] Fabrication of double-sided thallium bromide strip detectors
    Hitomi, Keitaro
    Nagano, Nobumichi
    Onodera, Toshiyuki
    Kim, Seong-Yun
    Ito, Tatsuya
    Ishii, Keizo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 823 : 15 - 19
  • [46] Radiation damages in double-sided silicon strip module
    Germain, M
    Arnold, L
    Baudot, J
    Bonnet, D
    Coffin, JP
    Dulinski, W
    Gojak, C
    Guillaume, G
    Hippolyte, B
    Kuhn, C
    Lutz, JR
    Suire, C
    Tarchini, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (1-2): : 121 - 125
  • [47] Charge Collection Studies and Electrical Measurements of Heavily Irradiated 3D Double-Sided Sensors and Comparison to Planar Strip Detectors
    Bates, Richard L.
    Parkes, C.
    Rakotomiaramanana, Barinjaka
    Fleta, C.
    Pellegrini, Giulio
    Lozano, M.
    Balbuena, J. P.
    Parzefall, Ulrich
    Koehler, M.
    Breindl, M.
    Blot, X.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (06) : 3370 - 3383
  • [48] Double-sided TlBr strip detectors for SPECT application
    Hitomi, K.
    Kikuchi, Y.
    Nakhostin, M.
    Shoji, T.
    Ishii, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S171 - S171
  • [49] Characterisation of the charge collection properties in a segmented planar HPGe detector
    Rintoul, E.
    Boston, A. J.
    Boston, H. C.
    Caffrey, A.
    Cresswell, J. R.
    Harkness-Brennan, L. J.
    Judson, D. S.
    Nolan, P. J.
    Platt, J.
    Unsworth, C.
    Woodroof, T. F.
    Lazarus, I. H.
    Simpson, J.
    Cocks, J.
    Walker, D.
    Pirard, B.
    Quirin, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 987
  • [50] INFLUENCE OF CHARGE COLLECTION CHARACTERISTICS ON HPGE DETECTOR TIMING PERFORMANCE
    ROBERTSON, BC
    NUCLEAR INSTRUMENTS & METHODS, 1980, 169 (03): : 465 - 468