Optimisation of positive end-expiratory pressure by forced oscillation technique in a lavage model of acute lung injury

被引:36
|
作者
Dellaca, Raffaele L. [1 ]
Zannin, Emanuela [1 ]
Kostic, Peter [2 ]
Olerud, Marie Andersson [2 ]
Pompilio, Pasquale P. [1 ]
Hedenstierna, Goran [3 ]
Pedotti, Antonio [1 ]
Frykholm, Peter [2 ]
机构
[1] Politecn Milan, Dipartimento Bioingn, I-20133 Milan, Italy
[2] Uppsala Univ, Dept Surg Sci Anaesthesia & Intens Care, Uppsala, Sweden
[3] Uppsala Univ, Dept Med Sci Clin Physiol, Uppsala, Sweden
基金
瑞典研究理事会;
关键词
Forced oscillation technique; Lung mechanics; Mechanical ventilation; Positive end-expiratory pressure; Lung volume recruitment; Computed tomography; ARDS; RESPIRATORY-DISTRESS-SYNDROME; RANDOMIZED CONTROLLED-TRIAL; COMPUTED-TOMOGRAPHY; REGIONAL-DISTRIBUTION; FLOW LIMITATION; AIRWAY PRESSURE; MECHANICAL VENTILATION; ALVEOLAR RECRUITMENT; CURVE PROFILE; TIDAL VOLUME;
D O I
10.1007/s00134-011-2211-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We evaluated whether oscillatory compliance (C-X5) measured by forced oscillation technique (FOT) at 5 Hz may be useful for positive end-expiratory pressure (PEEP) optimisation. We studied seven pigs in which lung injury was induced by broncho-alveolar lavage. The animals were ventilated in volume control mode with a tidal volume of 6 ml/kg. Forced oscillations were superimposed on the ventilation waveform for the assessment of respiratory mechanics. PEEP was increased from 0 to 24 cmH(2)O in steps of 4 cmH(2)O and subsequently decreased from 24 to 0 in steps of 2 cmH(2)O. At each 8-min step, a CT scan was acquired during an end-expiratory hold, and blood gas analysis was performed. C-X5 was monitored continuously, and data relative to the expiratory hold were selected and averaged for comparison with CT and oxygenation. Open lung PEEP (PEEPol) was defined as the level of PEEP corresponding to the maximum value of C-X5 on the decremental limb of the PEEP trial. PEEPol was on average 13.4 (+/- 1.0) cmH(2)O. For higher levels of PEEP, there were no significant changes in the amount of non-aerated tissue (V-tissNA%). In contrast, when PEEP was reduced below PEEPol, V-tissNA% dramatically increased. PEEPol was able to prevent a 5% drop in V-tissNA% with 100% sensitivity and 92% specificity. At PEEPol V-tissNA% was significantly lower than at the corresponding PEEP level on the incremental limb. The assessment of C-X5 allowed the definition of PEEPol to be in agreement with CT data. Thus, FOT measurements of C-X5 may provide a non-invasive bedside tool for PEEP titration.
引用
收藏
页码:1021 / 1030
页数:10
相关论文
共 50 条
  • [41] Positive End-Expiratory Pressure Levels in Adult Patients With Acute Lung Injury and Acute Respiratory Distress Syndrome
    Cooper, Adam S.
    CRITICAL CARE NURSE, 2023, 43 (02) : 77 - 79
  • [42] Bedside assessment of the effects of positive end-expiratory pressure on lung inflation and recruitment by the helium dilution technique and electrical impedance tomography
    Mauri, Tommaso
    Eronia, Nilde
    Turrini, Cecilia
    Battistini, Marta
    Grasselli, Giacomo
    Rona, Roberto
    Volta, Carlo Alberto
    Bellani, Giacomo
    Pesenti, Antonio
    INTENSIVE CARE MEDICINE, 2016, 42 (10) : 1576 - 1587
  • [43] Effects of positive end-expiratory pressure and recruitment maneuvers in a ventilator-induced injury mouse model
    Cagle, Laura A.
    Franzi, Lisa M.
    Linderholm, Angela L.
    Last, Jerold A.
    Adams, Jason Y.
    Harper, Richart W.
    Kenyon, Nicholas J.
    PLOS ONE, 2017, 12 (11):
  • [44] Influence of neurally adjusted ventilatory assist and positive end-expiratory pressure on breathing pattern in rabbits with acute lung injury
    Allo, Jean-Christophe
    Beck, Jennifer C.
    Brander, Lukas
    Brunet, Fabrice
    Slutsky, Arthur S.
    Sinderby, Christer A.
    CRITICAL CARE MEDICINE, 2006, 34 (12) : 2997 - 3004
  • [45] The role of positive end-expiratory pressure in modulating the apoptosis response during atelectasis-induced lung injury
    Davide, Chiumello
    CRITICAL CARE MEDICINE, 2009, 37 (03) : 1161 - 1162
  • [46] Dynamics of end expiratory lung volume after changing positive end-expiratory pressure in acute respiratory distress syndrome patients
    Garnero, Aude
    Tuxen, David
    Corno, Gaelle
    Durand-Gasselin, Jacques
    Hodgson, Carol
    Arnal, Jean-Michel
    CRITICAL CARE, 2015, 19
  • [47] Positive end-expiratory pressure-induced recruited lung volume measured by volume-pressure curves in acute respiratory distress syndrome: a physiologic systematic review and meta-analysis
    Turbil, Emanuele
    Terzi, Nicolas
    Cour, Martin
    Argaud, Laurent
    Einav, Sharon
    Guerin, Claude
    INTENSIVE CARE MEDICINE, 2020, 46 (12) : 2212 - 2225
  • [48] Positive end-expiratory pressure individualization guided by continuous end-expiratory lung volume monitoring during laparoscopic surgery
    Tusman, Gerardo
    Wallin, Mats
    Acosta, Cecilia
    Santanera, Bruno
    Portela, Facundo
    Viotti, Federico
    Fuentes, Nora
    Hallback, Magnus
    Suarez-Sipmann, Fernando
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (05) : 1557 - 1567
  • [49] Effect of transpulmonary pressure-guided positive end-expiratory pressure titration on lung injury in pigs with acute respiratory distress syndrome
    Xiaoyan Wu
    Ruiqiang Zheng
    Zhiqing Zhuang
    Journal of Clinical Monitoring and Computing, 2020, 34 : 151 - 159
  • [50] Effect of transpulmonary pressure-guided positive end-expiratory pressure titration on lung injury in pigs with acute respiratory distress syndrome
    Wu, Xiaoyan
    Zheng, Ruiqiang
    Zhuang, Zhiqing
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2020, 34 (01) : 151 - 159