Optimisation of positive end-expiratory pressure by forced oscillation technique in a lavage model of acute lung injury

被引:36
|
作者
Dellaca, Raffaele L. [1 ]
Zannin, Emanuela [1 ]
Kostic, Peter [2 ]
Olerud, Marie Andersson [2 ]
Pompilio, Pasquale P. [1 ]
Hedenstierna, Goran [3 ]
Pedotti, Antonio [1 ]
Frykholm, Peter [2 ]
机构
[1] Politecn Milan, Dipartimento Bioingn, I-20133 Milan, Italy
[2] Uppsala Univ, Dept Surg Sci Anaesthesia & Intens Care, Uppsala, Sweden
[3] Uppsala Univ, Dept Med Sci Clin Physiol, Uppsala, Sweden
基金
瑞典研究理事会;
关键词
Forced oscillation technique; Lung mechanics; Mechanical ventilation; Positive end-expiratory pressure; Lung volume recruitment; Computed tomography; ARDS; RESPIRATORY-DISTRESS-SYNDROME; RANDOMIZED CONTROLLED-TRIAL; COMPUTED-TOMOGRAPHY; REGIONAL-DISTRIBUTION; FLOW LIMITATION; AIRWAY PRESSURE; MECHANICAL VENTILATION; ALVEOLAR RECRUITMENT; CURVE PROFILE; TIDAL VOLUME;
D O I
10.1007/s00134-011-2211-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We evaluated whether oscillatory compliance (C-X5) measured by forced oscillation technique (FOT) at 5 Hz may be useful for positive end-expiratory pressure (PEEP) optimisation. We studied seven pigs in which lung injury was induced by broncho-alveolar lavage. The animals were ventilated in volume control mode with a tidal volume of 6 ml/kg. Forced oscillations were superimposed on the ventilation waveform for the assessment of respiratory mechanics. PEEP was increased from 0 to 24 cmH(2)O in steps of 4 cmH(2)O and subsequently decreased from 24 to 0 in steps of 2 cmH(2)O. At each 8-min step, a CT scan was acquired during an end-expiratory hold, and blood gas analysis was performed. C-X5 was monitored continuously, and data relative to the expiratory hold were selected and averaged for comparison with CT and oxygenation. Open lung PEEP (PEEPol) was defined as the level of PEEP corresponding to the maximum value of C-X5 on the decremental limb of the PEEP trial. PEEPol was on average 13.4 (+/- 1.0) cmH(2)O. For higher levels of PEEP, there were no significant changes in the amount of non-aerated tissue (V-tissNA%). In contrast, when PEEP was reduced below PEEPol, V-tissNA% dramatically increased. PEEPol was able to prevent a 5% drop in V-tissNA% with 100% sensitivity and 92% specificity. At PEEPol V-tissNA% was significantly lower than at the corresponding PEEP level on the incremental limb. The assessment of C-X5 allowed the definition of PEEPol to be in agreement with CT data. Thus, FOT measurements of C-X5 may provide a non-invasive bedside tool for PEEP titration.
引用
收藏
页码:1021 / 1030
页数:10
相关论文
共 50 条
  • [21] Should we titrate positive end-expiratory pressure based on an end-expiratory transpulmonary pressure?
    Marini, John J.
    ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6 (19)
  • [22] Pulmonary lesion induced by low and high positive end-expiratory pressure levels during protective ventilation in experimental acute lung injury
    Passaro, Caroline P.
    Silva, Pedro L.
    Rzezinski, Andreia F.
    Abrantes, Simone
    Santiago, Viviane R.
    Nardelli, Liliane
    Santos, Raquel S.
    Barbosa, Carolina M. L.
    Morales, Marcelo M.
    Zin, Walter A.
    Amato, Marcelo B. P.
    Capelozzi, Vera L.
    Pelosi, Paolo
    Rocco, Patricia R. M.
    CRITICAL CARE MEDICINE, 2009, 37 (03) : 1011 - 1017
  • [23] High or conventional positive end-expiratory pressure in acute respiratory distress syndrome
    Diaz-Alersi, R.
    Navarro-Ramirez, C.
    MEDICINA INTENSIVA, 2014, 38 (05) : 311 - 314
  • [24] Progress in Clinical Application of Positive End-Expiratory Pressure
    Wu Zhaoxia
    Wen Xianjie
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (46A) : 526 - 537
  • [25] Searching for the optimal positive end-expiratory pressure for lung protective ventilation
    Sahetya, Sarina K.
    CURRENT OPINION IN CRITICAL CARE, 2020, 26 (01) : 53 - 58
  • [26] Cardiopulmonary Effects of Matching Positive End-Expiratory Pressure to Abdominal Pressure in Concomitant Abdominal Hypertension and Acute Lung Injury
    da Silva Almeida, Juliana Roberta
    Machado, Fabio Santana
    Pinto Schettino, Guilherme Paula
    Park, Marcelo
    Pontes Azevedo, Luciano Cesar
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 69 (02): : 375 - 382
  • [27] An intrinsic positive end-expiratory pressure lung model, with and without flow limitation
    Yang, KL
    Wang, C
    CRITICAL CARE MEDICINE, 1996, 24 (07) : 1261 - 1265
  • [28] Computed tomographic assessment of lung aeration at different positive end-expiratory pressures in a porcine model of intra-abdominal hypertension and lung injury
    Regli, Adrian
    Ahmadi-Noorbakhsh, Siavash
    Musk, Gabrielle Christine
    Reese, David Joseph
    Herrmann, Peter
    Firth, Martin Joseph
    Pillow, J. Jane
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2021, 9 (01)
  • [29] Experimental Ventilator-induced Lung Injury Exacerbation by Positive End-Expiratory Pressure
    Villar, Jesus
    Herrera-Abreu, Maria Teresa
    Valladares, Francisco
    Muros, Mercedes
    Perez-Mendez, Lina
    Flores, Carlos
    Kacmarek, Robert M.
    ANESTHESIOLOGY, 2009, 110 (06) : 1341 - 1347
  • [30] Pulmonary acute respiratory distress syndrome: positive end-expiratory pressure titration needs stress index
    Huang, Yingzi
    Yang, Yi
    Chen, Qiuhua
    Liu, Songqiao
    Liu, Ling
    Pan, Chun
    Yang, Congshan
    Qiu, Haibo
    JOURNAL OF SURGICAL RESEARCH, 2013, 185 (01) : 347 - 352