Percutaneous biliary stent combined with brachytherapy using 125I seeds for treatment of unresectable malignant obstructive jaundice: A meta-analysis

被引:3
|
作者
Chen, Wei-Yue [1 ]
Kong, Chun-Li [1 ]
Meng, Miao-Miao [1 ]
Chen, Wei-Qian [1 ]
Zheng, Li-Yun [1 ]
Mao, Jian-Ting [1 ]
Fang, Shi-Ji [1 ]
Chen, Li [1 ]
Shu, Gao-Feng [1 ]
Yang, Yang [1 ]
Weng, Qiao-You [1 ]
Chen, Min-Jiang [1 ]
Xu, Min [1 ]
Ji, Jian-Song [1 ]
机构
[1] Lishui Hosp Zhejiang Univ, Key Lab Imaging Diag & Minimally Invas Intervent, Dept Radiol, Lishui Hosp, 289 Kuocang Rd, Lishui 323000, Zhejiang, Peoples R China
关键词
Malignant obstructive jaundice; Brachytherapy; I-125; seed; Patency; Survival; Meta-analysis; METAL STENTS; PLACEMENT; EFFICACY; STRANDS; SAFETY;
D O I
10.12998/wjcc.v9.i35.10979
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Malignant obstructive jaundice (MOJ) is a common pathologic manifestation of malignant biliary obstruction. Recently, several clinical trials have explored the clinical effectiveness of intraluminal I-125 seed- based brachytherapy for MOJ patients, and various outcomes have been reported. AIM To assess the efficacy and safety of percutaneous biliary stents with I-125 seeds compared to conventional metal stents in patients with unresectable MOJ. METHODS A systematic search of English-language databases (PubMed, Embase, Cochrane Library, and Web of Science) was performed to identify studies published prior to June 2020 that compared stents with or without I-125 seeds in the treatment of unresectable MOJ. The outcomes analyzed included primary outcomes (stent patency and overall survival) and secondary outcomes (complications and liver function parameters). RESULTS Six randomized controlled trials and four retrospective studies involving 875 patients were eligible for the analysis. Of the 875 included patients, 404 were treated with I-125 seed stents, while 471 were treated with conventional stents. Unadjusted pooled analysis demonstrated that compared to conventional stents, I-125 seed stents extended the stent patency time [hazard ratio (HR) = 0.36, 95% confidence interval (CI) = 0.28-0.45, P < 0.0001] and overall survival period (HR = 0.52, 95%CI = 0.42-0.64, P < 0.00001). Subgroup analyses based on the type of I-125 seed stent and type of study design showed consistent results. However, there were no significant differences in the occurrence of total complications [odds ratio (OR) = 1.12, 95%CI = 0.75-1.67, P = 0.57], hemobilia (OR = 1.02, 95%CI = 0.45-2.3, P = 0.96), pancreatitis (OR = 1.79, 95%CI = 0.42-7.53, P = 0.43), cholangitis (OR = 1.13, 95%CI = 0.60-2.13, P = 0.71), or pain (OR = 0.67, 95%CI = 0.22-2, P = 0.47). In addition, there were no reductions in the levels of serum indices, including total bilirubin [mean difference (MD) = 10.96, 95%CI = -3.56-25.49, P = 0.14], direct bilirubin (MD = 7.37, 95%CI = -9.76-24.5, P = 0.4), alanine aminotransferase (MD = 7.52, 95%CI = -0.71-15.74, P = 0.07), and aspartate aminotransferase (MD = -4.77, 95%CI = -19.98-10.44, P = 0.54), after treatment. Publication bias was detected regarding the outcome overall survival; however, the conclusions were not changed after the adjustment. CONCLUSION Placement of stents combined with brachytherapy using I-125 seeds contributes to a longer stent patency and higher overall survival than placement of conventional stents without extra complications or severe liver damage. Thus, it can be considered an effective and safe treatment for unresectable MOJ.
引用
收藏
页码:10979 / 10993
页数:15
相关论文
共 49 条
  • [1] Biliary stent with or without 125I seeds for malignant obstructive jaundice: a systematic review and meta-analysis
    Abuduwaili, Saimaiti
    Tao, Li
    Tuerxun, Kahaer
    Li, Yu-Peng
    Hao, Zhang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (11): : 11911 - +
  • [2] Safety and efficacy of self-expandable metallic stent combined with 125I brachytherapy for the treatment of malignant obstructive jaundice
    Sheng, Ye
    Fu, Xiaobo
    Wang, Guobao
    Mu, Maoyuan
    Jiang, Weiwei
    Chen, Zixiong
    Qi, Han
    Gao, Fei
    CANCER IMAGING, 2023, 23 (01)
  • [3] A Comparative Study of Self-Expandable Metallic Stent Combined with Double 125I Seeds Strands or Single 125I Seeds Strand in the Treatment of Advanced Perihilar Cholangiocarcinoma with Malignant Obstructive Jaundice
    Li, Zhaonan
    Jiao, Dechao
    Han, Xinwei
    Liu, Zaoqu
    ONCOTARGETS AND THERAPY, 2021, 14 : 4077 - 4086
  • [4] Safety and efficacy of self-expandable metallic stent combined with 125I brachytherapy for the treatment of malignant obstructive jaundice
    Ye Sheng
    Xiaobo Fu
    Guobao Wang
    Maoyuan Mu
    Weiwei Jiang
    Zixiong Chen
    Han Qi
    Fei Gao
    Cancer Imaging, 23
  • [5] Iodine-125 Seeds Combined With Biliary Stent Placement Versus Stent Placement Alone For Unresectable Malignant Biliary Obstruction: A Meta-Analysis Of Randomized Controlled Trials
    Xiang, Yucheng
    Lu, Sinan
    Li, Yufeng
    Liu, Zhenghao
    Wang, Weilin
    JOURNAL OF CANCER, 2021, 12 (05): : 1334 - 1342
  • [6] A Systematic Review and Meta-analysis of Intraluminal Brachytherapy Versus Stent Alone in the Treatment of Malignant Obstructive Jaundice
    Xu, Xinjian
    Li, Jingjing
    Wu, Juan
    Zhu, Rui
    Ji, Wenbin
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (02) : 206 - 217
  • [7] Preliminary application of brachytherapy with double-strand 125I seeds and biliary drainage for malignant obstructive jaundice
    Li, Zong-Ming
    Jiao, De-Chao
    Han, Xin-Wei
    Lei, Qin-Yu
    Zhou, Xue-Liang
    Xu, Miao
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (07): : 4932 - 4938
  • [8] Percutaneous biliary metallic stenting and 125I seed implantation for the treatment of malignant obstructive jaundice
    Wang, Song
    Yu, Chunpeng
    Zhu, Jiafeng
    BIOMEDICAL RESEARCH-INDIA, 2014, 25 (04): : 511 - 514
  • [9] The Use of 125I Seed Strands for Intraluminal Brachytherapy of Malignant Obstructive Jaundice
    Chen, Yi
    Wang, Xiao-Lin
    Yan, Zhi-Ping
    Wang, Jian-Hua
    Cheng, Jie-Min
    Gong, Gao-Quan
    Luo, Jian-Jun
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2012, 27 (05) : 317 - 323
  • [10] 125I Seed-Loaded Stents and 125I Seed Strips for the Treatment of Unresectable Malignant Obstructive Jaundice
    Wang, Wenhui
    Li, Shuangxi
    Li, Baohua
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2020, 12 (03) : 418 - 425