Normal incidence sound transmission loss evaluation with a general upstream tube wave decomposition formula

被引:2
|
作者
Wei, Zhengyu [1 ]
Hou, Hong [1 ]
Gao, Nansha [1 ]
Huang, Yunke [1 ]
Yang, Jianhua [2 ]
机构
[1] Northwestern Polytech Univ, Sch Marine Sci & Technol, Xian 710072, Shaanxi, Peoples R China
[2] Northwestern Polytech Univ, Sch Automat, Xian 710072, Shaanxi, Peoples R China
来源
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA | 2018年 / 144卷 / 04期
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
DUCT ACOUSTIC PROPERTIES; CHARACTERISTIC IMPEDANCE; ABSORPTION;
D O I
10.1121/1.5064282
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study presents a method for measuring the normal incidence sound transmission loss of acoustical materials used in classical piping systems from upstream surface complex reflection coefficient measurements only. Based on the standard transfer function method, the wave field of the upstream tube is further decomposed, and the relationship between the complex reflection coefficient and the twice-transmitted wave is deduced. Similar to the so-called upstream surface impedance (USI) method, two microphone locations and air cavities with several depths are required. As a validation of the proposed method, both symmetrical and non-symmetrical materials are investigated. The influence of the air cavity on the experiment result is also discussed. A comparison of the results between the proposed method and existing methods reveals a perfect agreement with the verified USI method. (C) 2018 Acoustical Society of America.
引用
收藏
页码:2344 / 2353
页数:10
相关论文
共 50 条
  • [1] A general wave decomposition formula for the measurement of normal incidence sound transmission loss in impedance tube
    Salissou, Yacoubou
    Panneton, Raymond
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2009, 125 (04): : 2083 - 2090
  • [2] Normal incidence sound transmission loss evaluation by upstream surface impedance measurements
    Panneton, Raymond
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2009, 125 (03): : 1490 - 1497
  • [3] Evaluation of the bias error of transmission tube measurements of normal-incidence sound transmission loss using narrow tube reference elements
    Orduna-Bustamante, Felipe
    Arturo Machuca-Tzili, F.
    Velasco-Segura, Roberto
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2018, 144 (02): : 1040 - 1048
  • [4] Normal incidence sound transmission loss in impedance tube - Measurement and prediction methods using perforated plates
    Vigran, T. E.
    APPLIED ACOUSTICS, 2012, 73 (04) : 454 - 459
  • [5] An improved approach for normal-incidence sound transmission loss measurement using a four-microphone impedance tube
    Li Zechao
    Chen Sizhong
    Wu Zhicheng
    Yang Lin
    JOURNAL OF VIBRATION AND CONTROL, 2021, 27 (3-4) : 332 - 342
  • [6] Complement to standard method for measuring normal incidence sound transmission loss with three microphones
    Salissou, Yacoubou
    Panneton, Raymond
    Doutres, Olivier
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2012, 131 (03): : EL216 - EL222
  • [7] Evaluation of Materials for Sound Transmission Loss
    Proc Int Conf Noise Control Eng, 5 (2743):
  • [8] Evaluation of materials for sound transmission loss
    Sorenson, S
    INTER-NOISE 96 - THE 1996 INTERNATIONAL CONGRESS ON NOISE CONTROL ENGINEERING, 25TH ANNIVERSARY CONGRESS - LIVERPOOL, PROCEEDINGS, BOOKS 1-6: NOISE CONTROL - THE NEXT 25 YEARS, 1996, : 2743 - 2746
  • [9] Analysis of the tolerance of sound transmission loss measured by four-microphone in standing wave tube
    Wu, Hai-Jun
    Jiang, Wei-Kang
    Li, Liang-Jun
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2008, 42 (08): : 1265 - 1268
  • [10] Normal Incidence of Sound Transmission Loss of a Double-Leaf Partition Inserted with a Microperforated Panel
    Putra, A.
    Ismail, A. Y.
    Ramlan, R.
    Ayob, Md. R.
    Py, M. S.
    ADVANCES IN ACOUSTICS AND VIBRATION, 2013, 2013