3D handheld laser scanner based approach for automatic identification and localization of EEG sensors

被引:11
作者
Koessler, Laurent [1 ,2 ]
Cecchin, Thierry [3 ]
Ternisien, Eric [3 ]
Maillard, Louis [1 ,2 ]
机构
[1] Nancy Univ, CNRS, CRAN, Nancy, France
[2] Ctr Hosp Univ Nancy, Nancy, France
[3] Univ Nancy, F-54013 Nancy, France
来源
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2010年
关键词
SOMATOSENSORY-EVOKED POTENTIALS; MRI VOLUME; STIMULATION; ELECTRODES;
D O I
10.1109/IEMBS.2010.5627659
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes and assesses for the first time the use of a handheld 3D laser scanner for scalp EEG sensor localization and co-registration with magnetic resonance images. Study on five subjects showed that the scanner had an equivalent accuracy, a better repeatability, and was faster than the reference electromagnetic digitizer. According to electrical source imaging, somatosensory evoked potentials experiments validated its ability to give precise sensor localization. With our automatic labeling method, the data provided by the scanner could be directly introduced in the source localization studies.
引用
收藏
页码:3707 / 3710
页数:4
相关论文
共 13 条
[1]   Single Camera Photogrammetry System for EEG Electrode Identification and Localization [J].
Baysal, Ugur ;
Sengul, Gokhan .
ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (04) :1539-1547
[2]   Scalp-recorded EEG localization in MRI volume data [J].
Brinkmann, BH ;
O'Brien, TJ ;
Dresner, MA ;
Lagerlund, TD ;
Sharbrough, W ;
Robb, RA .
BRAIN TOPOGRAPHY, 1998, 10 (04) :245-253
[3]   A self-referenced hand-held range sensor [J].
Hébert, P .
THIRD INTERNATIONAL CONFERENCE ON 3-D DIGITAL IMAGING AND MODELING, PROCEEDINGS, 2001, :5-12
[4]  
HEBERT P, 2008, Patent No. 20080201101
[5]   Automatic localization and labeling of EEG sensors (ALLES) in MRI volume [J].
Koessler, L. ;
Benhadid, A. ;
Maillard, L. ;
Vignal, J. P. ;
Felblinger, J. ;
Vespignani, H. ;
Braun, M. .
NEUROIMAGE, 2008, 41 (03) :914-923
[6]   Spatial localization of EEG electrodes [J].
Koessler, L. ;
Maillard, L. ;
Benhadid, A. ;
Vignal, J.-P. ;
Braun, M. ;
Vespignani, H. .
NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2007, 37 (02) :97-102
[7]   Automatic alignment of EEG/MEG and MRI data sets [J].
Kozinska, D ;
Carducci, F ;
Nowinski, K .
CLINICAL NEUROPHYSIOLOGY, 2001, 112 (08) :1553-1561
[8]   A rapid method for determining standard 10/10 electrode positions for high resolution EEG studies [J].
Le, J ;
Lu, M ;
Pellouchoud, E ;
Gevins, A .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 106 (06) :554-558
[9]   Automatic labeling of EEG electrodes using combinatorial optimization [J].
Pechaud, Mickael ;
Keriven, Rcnaud ;
Papadopoulo, Theo ;
Badier, Jean-Michel .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :4398-+
[10]  
SPICLIN Z, 2008, P 11 INT C MED IM CO, P762