Axon diameter inferences in the human corpus callosum using oscillating gradient spin echo sequences

被引:6
作者
Herrera, Sheryl L. [1 ,2 ]
Sheft, Maxina [1 ,3 ]
Mercredi, Morgan E. [4 ]
Buist, Richard [5 ]
Matsuda, Kant M. [6 ]
Martin, Melanie [1 ]
机构
[1] Univ Winnipeg, Phys, Winnipeg, MB, Canada
[2] Cubresa Inc, Winnipeg, MB, Canada
[3] Georgia Inst Technol, Biomed Engn, Atlanta, GA 30332 USA
[4] Univ Manitoba, Phys & Astron, Winnipeg, MB, Canada
[5] Univ Manitoba, Radiol, Winnipeg, MB, Canada
[6] Rutgers State Univ, Robert Wood Johnson RWJ Med Sch, Pathol, New Brunswick, NJ 08901 USA
关键词
OGSE; Axon diameter; Corpus callosum; MRI; Electron microscopy; Temporal diffusion spectroscopy; CONDUCTION-VELOCITY; RESTRICTED DIFFUSION; WHITE-MATTER; CELL-SIZE; MICROSTRUCTURE; MRI; NEURODEGENERATION; AXCALIBER; MODEL;
D O I
10.1016/j.mri.2021.10.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Previous methods used to infer axon diameter distributions using magnetic resonance imaging (MRI) primarily use single diffusion encoding sequences such as pulsed gradient spin echo (PGSE) and are thus sensitive to axons of diameters >5 um. We applied oscillating gradient spin echo (OGSE) sequences to study human axons in the 1-2 um range in the corpus callosum, which include the majority of axons constituting cortical connections. The ActiveAx model was applied to calculate the fitted mean effective diameter for axons (AxD) and was compared with values found using histology. Axon diameters from histological data were calculated using three different datasets; true diameters (minimum diameter), a combination of minimum and maximum diameters, and diameters measured across a consistent diffusion direction. The AxD estimates from MRI were 1.8 +/- 0.1 mu m to 2.34 +/- 0.04 um with an average of 2.0 +/- 0.2 mu m for the ActiveAx model. The histology AxD values were 1.43 +/- 0.02 mu m when using the true minimum axon diameters, 5.52 +/- 0.02 mu m when using the combination of minimum and maximum axon diameters, and 2.20 +/- 0.02 mu m when collecting measurements across a consistent diffusion direction. This experiment demonstrates the first known usage of OGSE to calculate axon diameters in the human corpus callosum on a 1-2 mu m scale. The importance for the model to account for axonal orientation dispersion is indicated by histological results which more closely match the MRI model results depending on the direction of axon diameter measurements. These initial steps using this non-invasive imaging method can be applied to future methodology to develop in vivo axon diameter measurements in human brain tissue.
引用
收藏
页码:64 / 70
页数:7
相关论文
共 47 条
[1]   Probing mouse brain microstructure using oscillating gradient diffusion MRI [J].
Aggarwal, Manisha ;
Jones, Melina V. ;
Calabresi, Peter A. ;
Mori, Susumu ;
Zhang, Jiangyang .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (01) :98-109
[2]   Assessment of White Matter Tract Damage in Patients with Amyotrophic Lateral Sclerosis: A Diffusion Tensor MR Imaging Tractography Study [J].
Agosta, F. ;
Pagani, E. ;
Petrolini, M. ;
Caputo, D. ;
Perini, M. ;
Prelle, A. ;
Salvi, F. ;
Filippi, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (08) :1457-1461
[3]   Orientationally invariant indices of axon diameter and density from diffusion MRI [J].
Alexander, Daniel C. ;
Hubbard, Penny L. ;
Hall, Matt G. ;
Moore, Elizabeth A. ;
Ptito, Maurice ;
Parker, Geoff J. M. ;
Dyrby, Tim B. .
NEUROIMAGE, 2010, 52 (04) :1374-1389
[4]  
Armstrong RA., 2009, J OPTOM, V2, P103, DOI DOI 10.3921/JOPTOM.2009.103
[5]   AxCaliber: A method for measuring axon diameter distribution from diffusion MRI [J].
Assaf, Yaniv ;
Blumenfeld-Katzir, Tamar ;
Yovel, Yossi ;
Basser, Peter J. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (06) :1347-1354
[6]   In vivo measurement of axon diameter distribution in the corpus callosum of rat brain [J].
Barazany, Daniel ;
Basser, Peter J. ;
Assaf, Yaniv .
BRAIN, 2009, 132 :1210-1220
[7]  
Cluskey S, 2001, J CLIN PATHOL-MOL PA, V54, P386
[8]   New insights into tumor microstructure using temporal diffusion spectroscopy [J].
Colvin, Daniel C. ;
Yankeelov, Thomas E. ;
Does, Mark D. ;
Yue, Zoe ;
Quarles, Chad ;
Gore, John C. .
CANCER RESEARCH, 2008, 68 (14) :5941-5947
[9]   Earlier detection of tumor treatment response using magnetic resonance diffusion imaging with oscillating gradients [J].
Colvin, Daniel C. ;
Loveless, Mary E. ;
Does, Mark D. ;
Yue, Zou ;
Yankeelov, Thomas E. ;
Gore, John C. .
MAGNETIC RESONANCE IMAGING, 2011, 29 (03) :315-323
[10]  
Coronado-Leija R, 2021, P 2021 ANN M EXHIBIT