Focal Suppression of Epileptiform Activity in the Hippocampus by a High-frequency Magnetic Field

被引:12
|
作者
Ye, Hui [1 ]
Chen, Vincent C-F [2 ]
Helon, Jessica [1 ]
Apostolopoulos, Nicole [1 ]
机构
[1] Loyola Univ Chicago, Dept Biol, Chicago, IL 60660 USA
[2] Loyola Univ Chicago, Engn Sci Program, Chicago, IL 60660 USA
关键词
magnetic coil; induced electric field; hippocampus; epilepsy; electrophysiology; LONG-TERM POTENTIATION; ELECTRICAL-STIMULATION; IN-VITRO; SEIZURE SUPPRESSION; BRAIN-STIMULATION; PYRAMIDAL NEURONS; THALAMIC NUCLEUS; GLOBUS-PALLIDUS; ICTAL ACTIVITY; LOBE EPILEPSY;
D O I
10.1016/j.neuroscience.2020.02.018
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Electric current has been used for epilepsy treatment by targeting specific neural circuitries. Despite its success, direct contact between the electrode and tissue could cause side effects including pain, inflammation, and adverse biological reactions. Magnetic stimulation overcomes these limitations by offering advantages over biocompatibility and operational feasibility. However, the underlying neurological mechanisms of its action are largely unknown. In this work, a magnetic generating system was assembled that included a miniature coil. The coil was positioned above the CA3 area of mouse hippocampal slices. Epileptiform activity (EFA) was induced with low Mg2+/high K+ perfusion or with 100 mu M 4-aminopyridine (4-AP). The miniature coil generated a sizable electric field that suppressed the local EFA in the hippocampus in the low-Mg2+/high-K+ model. The inhibition effect was dependent on the frequency and duration of the magnetic stimulus, with high frequency being more effective in suppressing EFA. EFA suppression by the magnetic field was also observed in the 4-AP model, in a frequency and duration - dependent manner. The study provides a platform for further investigation of cellular and molecular mechanisms underlying epilepsy treatment with time varying magnetic fields. (C) 2020 IBRO. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [1] Suppressing synchronous firing of epileptiform activity by high-frequency stimulation of afferent fibers in rat hippocampus
    Wang, Zhaoxiang
    Feng, Zhouyan
    Yuan, Yue
    Zheng, Lvpiao
    CNS NEUROSCIENCE & THERAPEUTICS, 2021, 27 (03) : 352 - 362
  • [2] Suppression of Marangoni convection in the FZ melt by high-frequency magnetic field
    Munakata, T
    Someya, S
    Tanasawa, I
    JOURNAL OF CRYSTAL GROWTH, 2002, 235 (1-4) : 167 - 172
  • [3] HIGH-FREQUENCY COMPONENTS IN EPILEPTIFORM EEG
    HUANG, CM
    WHITE, LE
    JOURNAL OF NEUROSCIENCE METHODS, 1989, 30 (03) : 197 - 201
  • [4] High-frequency cortical activity associated with postischemic epileptiform discharges in an in vivo rat focal stroke model Laboratory investigation
    Srejic, Luka R.
    Valiante, Taufik A.
    Aarts, Michelle M.
    Hutchison, William D.
    JOURNAL OF NEUROSURGERY, 2013, 118 (05) : 1098 - 1106
  • [5] High-frequency cortical activity associated with post-ischemic epileptiform discharges in a rat focal stroke model in vivo
    Srejic, L. R.
    Hutchison, W. D.
    Aarts, M. M.
    STROKE, 2010, 41 (07) : E488 - E488
  • [6] Suppression of epileptiform activity by a single short-duration electric field in rat hippocampus in vitro
    Mikkelsen, Ronni
    Andreasen, Mogens
    Nedergaard, Steen
    JOURNAL OF NEUROPHYSIOLOGY, 2013, 109 (11) : 2720 - 2731
  • [7] INSTABILITY OF A HIGH-FREQUENCY DISCHARGE IN A MAGNETIC FIELD
    PINSKII, YM
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1967, 11 (07): : 865 - &
  • [8] ON HIGH-FREQUENCY OSCILLATIONS OF PLASMA IN MAGNETIC FIELD
    FEDORCHENKO, VD
    RUTKEVICH, B
    MURATOV, VI
    SOVIET PHYSICS-TECHNICAL PHYSICS, 1964, 9 (03): : 358 - &
  • [9] HIGH-FREQUENCY PLASMA CONDUCTIVITY IN A MAGNETIC FIELD
    OBERMAN, C