Highly Sensitive Temperature Sensor Using Intrinsic Mach-Zehnder Interferometer formed by Bent Micro-Fiber Embedded in Polymer

被引:0
作者
Munendhar, Pathi [1 ]
Zhang, Lei [1 ]
Tong, Limin [1 ]
Yu, Shaoliang [1 ]
机构
[1] Zhejiang Univ, State Key Lab Modern Opt Instrumentat, Coll Opt Sci & Engn, Hangzhou 310027, Zhejiang, Peoples R China
来源
2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS) | 2017年 / 10323卷
关键词
Mach-Zehnder interferometer; Tapered; Bent; microfiber; Highly-sensitive; Temperature sensor;
D O I
10.1117/12.2265817
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We reported a simple, robust, and highly sensitive temperature sensor using intrinsic Mach-Zehnder interferometer formed by means of bending a tapered microfiber, embedded in polydimethylsiloxane. The outer temperature perturbations modulate the refractive index of the polymer through thermo-optic and thermal expansion effects of the polymer. This leads to a phase difference between interfering guided modes through the bent-microfiber, which ultimately results prominent wavelength shift in the transmission spectrum. The sensor exhibits a linear temperature response with a sensitivity as high as -6.25nm/degrees C over the temperature range from 24 degrees to 40 degrees C. The sensitivity of the sensor increases as wavelength increases.
引用
收藏
页数:4
相关论文
共 11 条
[1]   Evanescent wave optical-fiber sensing (temperature, relative humidity, and pH sensors) [J].
Gaston, A ;
Lozano, I ;
Perez, F ;
Auza, F ;
Sevilla, J .
IEEE SENSORS JOURNAL, 2003, 3 (06) :806-811
[2]  
Guan Xiaowei, 2016, OPT EXP, P16350
[3]  
Hernandez-Romano Ivan, 2015, IEEE PHOT TECH LETTS, P2592
[4]   Fiber Mach-Zehnder interferometer based on microcavities for high-temperature sensing with high sensitivity [J].
Jiang, L. ;
Yang, J. ;
Wang, S. ;
Li, B. ;
Wang, M. .
OPTICS LETTERS, 2011, 36 (19) :3753-3755
[5]   Review of the present status of optical fiber sensors [J].
Lee, B .
OPTICAL FIBER TECHNOLOGY, 2003, 9 (02) :57-79
[6]  
McGee T. D., 1988, Principles and Methods of Temperature Measurement
[7]   All-fibre temperature sensor based on macro-bend singlemode fibre loop [J].
Rajan, G. ;
Semenova, Y. ;
Farrell, G. .
ELECTRONICS LETTERS, 2008, 44 (19) :1123-U11
[8]   In-fiber Bragg-Grating temperature sensor system for medical applications [J].
Rao, YJ ;
Webb, DJ ;
Jackson, DA ;
Zhang, L ;
Bennion, I .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1997, 15 (05) :779-785
[9]   Subwavelength-diameter silica wires for low-loss optical wave guiding [J].
Tong, LM ;
Gattass, RR ;
Ashcom, JB ;
He, SL ;
Lou, JY ;
Shen, MY ;
Maxwell, I ;
Mazur, E .
NATURE, 2003, 426 (6968) :816-819
[10]   Sensitivity-enhanced temperature sensor based on PDMS-coated long period fiber grating [J].
Wang, Qi ;
Du, Chao ;
Zhang, Jiaming ;
Lv, Riqing ;
Zhao, Yong .