Metal and composite bone plates for B1 periprosthetic femoral fracture in healthy and osteoporotic condition: A comparative biomechanical study

被引:2
|
作者
Dhason, Raja [1 ]
Roy, Sandipan [1 ]
Datta, Shubhabrata [1 ]
机构
[1] SRM Inst Sci & Technol, Dept Mech Engn, Kattankulathur 603203, Tamil Nadu, India
关键词
Periprosthetic femoral fracture; cemented hip arthroplasty; osteoporosis; finite element modeling; hip implant; bone plate; FINITE-ELEMENT-ANALYSIS; TOTAL HIP IMPLANT; FEMUR FRACTURES; FIXATION; TIP; QUALITY; REPAIR;
D O I
10.1177/03913988221108752
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The major concern after total hip arthroplasty (THA) is the incidence of periprosthetic fracture in the weaker bone, which can lead to subsequent revision surgery. Achieving the suitable fixation without affecting the stability of the well-fixed prosthesis remains controversial. Most of the studies examined the behavior of the Periprosthetic Fracture (PF) fixation (Vancouver "B1" type) through computational and experimentation on healthy bone condition with metal plates. The aim of the present study is to analyze the influences of the metal and composite bone plate PF fixation on the axial and shear movement at the fracture site. The PF fixation constructs were modeled with medical graded stainless-steel plate (construct A), titanium plate (construct B) and carbon/epoxy composite bone plate (construct C) with 12 holes and a 4 mm fracture gap. Analysis was carried out for all the stages (stage 1-Normal bone, stage 2-THA, stage 3-Immediate Post-Operative (IPO), stage 4-Post-Operative (PO) and, stage 5-Healed Bone (HB)) under various loadings for intact and osteoporosis conditions. The results showed higher stress in cortical bone for stage 3, whereas in all the other stages lower stresses were experienced in the cortical and cancelous bone under peak load in construct C for osteoporosis model compared with other constructs. The present study suggested the construct C may be suitable for osteoporosis bone conditions.
引用
收藏
页码:704 / 714
页数:11
相关论文
共 22 条
  • [1] Biomechanics of PHILOS plates in Vancouver B1 periprosthetic femoral fracture
    Yun, Changjun
    Qian, Wenjie
    Zhang, Jie
    Zhang, Wen
    Lv, Jinpeng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [2] A Biomechanical Comparison of Periprosthetic Femoral Fracture Fixation in Normal and Osteoporotic Cadaveric Bone
    Demos, Harry A.
    Briones, Marcus S.
    White, Peter H.
    Hogan, Kathleen A.
    Barfield, William R.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (05) : 783 - 788
  • [3] A biomechanical study on the laminate stacking sequence in composite bone plates for vancouver femur B1 fracture fixation
    Dhason, Raja
    Roy, Sandipan
    Datta, Shubhabrata
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 196
  • [4] Analysis of carbon fibre bone plate for "B1" type periprosthetic femoral fracture
    Raja, D.
    Roy, Sandipan
    Patil, Shantanu
    Datta, Shubhabrata
    3RD INTERNATIONAL CONFERENCE ON ADVANCES IN MECHANICAL ENGINEERING (ICAME 2020), PTS 1-6, 2020, 912
  • [5] Periprosthetic Femoral Fracture - A Biomechanical Comparison Between Vancouver Type B1 and B2 Fixation Methods
    Moazen, Mehran
    Mak, Jonathan H.
    Etchels, Lee W.
    Jin, Zhongmin
    Wilcox, Ruth K.
    Jones, Alison C.
    Tsiridis, Eleftherios
    JOURNAL OF ARTHROPLASTY, 2014, 29 (03) : 495 - 500
  • [6] Impact of bone health on the mechanics of plate fixation for Vancouver B1 periprosthetic femoral fractures
    Chen, Xiang
    Myers, Casey A.
    Clary, Chadd W.
    Varga, Peter
    Coombs, Dana
    DeWall, Ryan J.
    Fritz, Bryan
    Rullkoetter, Paul J.
    CLINICAL BIOMECHANICS, 2022, 100
  • [7] The Effect of Strut Allograft and Its Position on Vancouver Type B1 Periprosthetic Femoral Fractures: A Biomechanical Study
    Sariyilmaz, Kerim
    Dikici, Fatih
    Dikmen, Goksel
    Bozdag, Ergun
    Sunbuloglu, Emin
    Bekler, Bugra
    Yazicioglu, Onder
    JOURNAL OF ARTHROPLASTY, 2014, 29 (07) : 1485 - 1490
  • [8] The effect of onlay cortical fibula strut grafts on biomechanical features of Vancouver type B1 periprosthetic femoral fractures
    Aliyev, Orkhan
    Erden, Tunay
    Sariyilmaz, Kerim
    Bozdag, Ergun
    Sunbuloglu, Emin
    Tuncay, Ibrahim
    Yildiz, Fatih
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2022, 56 (03) : 166 - 172
  • [9] Double plating in Vancouver type B1 periprosthetic proximal femur fractures: A biomechanical study
    Waehnert, Dirk
    Grueneweller, Niklas
    Gehweiler, Dominic
    Brunn, Benjamin
    Raschke, Michael J.
    Stange, Richard
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (02) : 234 - 239
  • [10] BCIFS in the treatment of Vancouver type B1 periprosthetic femoral fracture combined with comminuted femoral stem fracture: A case report
    Yin, Lu
    Liu, Yang
    Zeng, Shengqiang
    Shen, Huarui
    ASIAN JOURNAL OF SURGERY, 2024, 47 (05) : 2274 - 2276