Single Phase Active Power Filter Control Under Distorted Grid Voltage Using Quasi Open-Loop Grid-Synchronization Technique

被引:0
作者
Biricik, Samet [1 ]
Ahmed, Hafiz [2 ]
Komurcugil, Hasan [3 ]
Guler, Naki [4 ]
Ozmen, Burcin [1 ]
Benbouzid, Mohamed [5 ,6 ]
机构
[1] European Univ Lefke, Dept Elect & Elect Engn, TR-10 Mersin, Northern Cyprus, Turkey
[2] Bangor Univ, Nucl Futures Inst, Bangor, Gwynedd, Wales
[3] Eastern Mediterranean Univ, Dept Comp Engn, Mersin 10, Famagusta, Turkey
[4] Gazi Univ, Tech Sci Vocat Sch, Elect & Energy Dept, Ankara, Turkey
[5] Univ Brest, UMR CNRS 6027 IRDL, Brest, France
[6] Shanghai Maritime Univ, Logist Engn Coll, Shanghai 201306, Peoples R China
来源
2021 12TH POWER ELECTRONICS, DRIVE SYSTEMS, AND TECHNOLOGIES CONFERENCE (PEDSTC) | 2021年
关键词
Active Power Filter; Grid-Synchronization; Adaptive Filtering; LOCKED LOOP; IMPLEMENTATION; REJECTION;
D O I
10.1109/PEDSTC52094.2021.9405949
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a quasi open-loop gridsynchronization technique-based control scheme for active power filter. The proposed filtering technique does not require any direct frequency feedback which has the advantage of unconditional stability. Based on the reference a current, a proportional integral and hysteresis band current control scheme is developed for fast and accurate tracking of the reference current by the APF's converter. Matlab/Simulink-based extensive numerical simulation studies are performed to demonstrate the robust performance of the proposed technique in distorted grid.
引用
收藏
页码:588 / 592
页数:5
相关论文
共 16 条
[1]   New digital reference current generation for shunt active power filter under distorted voltage conditions [J].
Abdusalam, Mohamed ;
Poure, Philippe ;
Karimi, Shahram ;
Saadate, Shahrokh .
ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (05) :759-765
[2]  
Ahmed Hafiz, 2020, 2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES), P350, DOI 10.1109/SPIES48661.2020.9242953
[3]  
Biricik S., 2018, 2018 IEEE 12 INT C C, P1
[4]   Grid Voltage Sensorless Single-Phase Half-Bridge Active Filter and DC Bus Voltage Regulation [J].
Biricik, Samet .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2017, 45 (19) :2131-2140
[5]   Real-time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self-tuning filter [J].
Biricik, Samet ;
Redif, Soydan ;
Ozerdem, Ozgur C. ;
Khadem, Shafiuzzaman K. ;
Basu, Malabika .
IET POWER ELECTRONICS, 2014, 7 (07) :1895-1905
[6]   A Novel Robust PLL Algorithm Applied To The Control Of A Shunt Active Power Filter Using A Self Tuning Filter Concept [J].
Chedjara, Zakaria ;
Massoum, Ahmed ;
Massoum, Sarra ;
Wira, Patrice ;
Safa, Ahmed ;
Gouichiche, Abdelmadjid .
2018 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2018, :1124-1131
[7]  
Eltarouty A, 2020, IEEE IND ELEC, P4967, DOI [10.1109/iecon43393.2020.9254426, 10.1109/IECON43393.2020.9254426]
[8]   Design and implementation of a three-level active power filter for harmonic and reactive power compensation [J].
Kashif, Muhammad ;
Hossain, M. J. ;
Zhuo, Fang ;
Gautam, Samir .
ELECTRIC POWER SYSTEMS RESEARCH, 2018, 165 :144-156
[9]   Enhanced structure of second-order generalized integrator frequency-locked loop suitable for DC-offset rejection in single-phase systems [J].
Kherbachi, Abdelhammid ;
Chouder, Aissa ;
Bendib, Ahmed ;
Kara, Kamel ;
Barkat, Said .
ELECTRIC POWER SYSTEMS RESEARCH, 2019, 170 :348-357
[10]   Double-band hysteresis current-controlled single-phase shunt active filter for switching frequency mitigation [J].
Komurcugil, Hasan .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 69 :131-140