Triaxial measurement of residual stress after high feed milling using x-ray diffraction

被引:12
|
作者
Zauskova, Lucia [1 ]
Czan, Andrej [1 ]
Sajgalik, Michal [1 ]
Drbul, Mario [1 ]
Rysava, Zdenka [2 ]
机构
[1] Univ Zilina, Dept Machining & Mfg Technol, Univ I, Zilina 01026, Slovakia
[2] Univ Padua, Dept Ind Engn, TESI Lab, Viale Porta Adige 45, I-45100 Rovigo, Italy
关键词
Residual stress; stress tensor; high feed milling;
D O I
10.1016/j.proeng.2017.06.169
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Surface integrity has been an important research topic in the last decades. Machining generates residual stresses in the surface and subsurface layers of the structural elements. The residual stress has a large influence on the functional properties of the components. X-ray diffractometry is a non-destructive method applicable for the measurement of residual stresses in surface and subsurface layers of components. The article deals with the method of triaxial measurement of residual stress after machining the surface of sample by high feed milling technology. Significance of triaxial measuring is the capability of measuring in different angles so it is possible to acquire stress tensor containing normal and shear stress components acting in the spot of measuring, using a Cartesian coordinate system. For comparison, a simple measurement of residual stresses in the point indicates the stress direction only in normal direction of the measured surface. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:982 / 987
页数:6
相关论文
共 50 条
  • [31] X-ray residual stress measurement on mechanical components with high curvature
    Berruti, T
    Gola, MM
    EXPERIMENTAL MECHANICS, 2003, 43 (01) : 105 - 114
  • [32] X-ray measurement of triaxial residual stress on machined surfaces by the cos method using a two-dimensional detector
    Tanaka, Keisuke
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2018, 51 : 1329 - 1338
  • [33] Effect of Peak Positioning Method on Accuracy of X-Ray Diffraction Residual Stress Measurement
    Sedighi, M.
    Nazemnezhad, R.
    EXPERIMENTAL TECHNIQUES, 2016, 40 (01) : 295 - 302
  • [34] Effect of Peak Positioning Method on Accuracy of X-Ray Diffraction Residual Stress Measurement
    M. Sedighi
    R. Nazemnezhad
    Experimental Techniques, 2016, 40 : 295 - 302
  • [35] Measurement of residual stress distributions by energy dispersive X-ray diffraction synchrotron radiation
    Tsakalakos, Thomas
    Croft, Mark C.
    Jisrawi, Najeh M.
    Holtz, Ronald L.
    Zhong, Zhong
    PROCEEDINGS OF THE SIXTEENTH (2006) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 4, 2006, : 57 - +
  • [36] Measurement of residual stress in single-crystal SiC by X-ray diffraction method
    Deng, Ya
    Zhang, Yumin
    Zhou, Yufeng
    Lixue Xuebao/Chinese Journal of Theoretical and Applied Mechanics, 2022, 54 (01): : 147 - 153
  • [37] Residual stress determination by the layer removal and X-ray diffraction measurement correction method
    Dlhy, Pavol
    Poduska, Jan
    Pokorny, Pavel
    Jambor, Michal
    Nahlik, Lubos
    Hutar, Pavel
    METHODSX, 2022, 9
  • [38] X-Ray Diffraction Technique for Residual Stress Measurement in NiCrMo Alloy Weld Metal
    Monine, Vladimir Ivanovitch
    Payao Filho, Joao da Cruz
    Gonzaga, Rodrigo Stohler
    Dias Passos, Elisa Kimus
    de Assis, Joaquim Teixeira
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2018, 2018
  • [39] X-RAY-DIFFRACTION RESIDUAL-STRESS MEASUREMENT
    PREVEY, PS
    EXPERIMENTAL MECHANICS, 1978, 18 (05) : N39 - N39
  • [40] The effect of sample position on the determination of triaxial stress by X-ray diffraction
    Fenn, R.H.
    Jones, A.M.
    Journal of Applied Crystallography, 1988, 21 (01): : 38 - 41