Anisotropy function for 192Ir low-dose-rate brachytherapy sources:: an EGS4 Monte Carlo study

被引:5
作者
Capote, R [1 ]
Mainegra, E [1 ]
López, E [1 ]
机构
[1] Ctr Estudios Aplicados Desarrollo Nucl, Dept Fis, La Habana, Cuba
关键词
D O I
10.1088/0031-9155/46/5/311
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The anisotropy function of low-dose-rate Ir-192 interstitial brachytherapy sources was studied. Absolute dose rates around Ir-192 seeds with stainless steel or platinum cladding and a platinum covered wire have been estimated using the EGS4 Monte Carlo simulation system with a very well tested user code. Our results were compared with available experimental data. Excellent agreement between calculated and measured anisotropy function was found for stainless steel clad Ir-192 sources, except along the longitudinal axis of the sources. Dosimetry data for the platinum covered seed and 3 mm long wire with platinum cladding as well as for the stainless steel clad Ir-192 source are presented in TG43 format. The influence of phantom dimensions on the anisotropy function was found to be non-negligible over 7 cm, enhancing the anisotropy function by 1-2%. Our results have estimated statistical uncertainties below 1% at 1 sigma level up to 10 cm excluding the longitudinal axis where statistical uncertainties below 3% up to 10 cm are observed.
引用
收藏
页码:1487 / 1499
页数:13
相关论文
共 35 条
  • [11] KNESCHAUREK P, 1985, STRAHLENTHER ONKOL, V161, P706
  • [12] LELIVELD CJ, 1995, IEEE MED IM C SAN FR
  • [13] DIRECTIONAL DEPENDENCE OF RADIATION FLUENCE FROM IR-192 AND AU-198 SOURCES
    LING, CC
    GROMADZKI, ZC
    RUSTGI, SN
    CUNDIFF, JH
    [J]. RADIOLOGY, 1983, 146 (03) : 791 - 792
  • [14] DOSIMETRIC CALCULATIONS AND MEASUREMENTS OF GOLD PLAQUE OPHTHALMIC IRRADIATORS USING IR-192 AND I-125 SEEDS
    LUXTON, G
    ASTRAHAN, MA
    LIGGETT, PE
    NEBLETT, DL
    COHEN, DM
    PETROVICH, Z
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 15 (01): : 167 - 176
  • [15] Dose rate constants for 125I, 103Pd, 192Ir and 169Yb brachytherapy sources:: an EGS4 Monte Carlo study
    Mainegra, E
    Capote, R
    Lopez, E
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) : 1557 - 1566
  • [16] Radial dose functions for 103Pd, 125I, 169Yb and 192Ir brachytherapy sources:: an EGS4 Monte Carlo study
    Mainegra, E
    Capote, R
    López, E
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (03) : 703 - 717
  • [17] EFFECTIVE ATTENUATION IN WATER OF GAMMA RAYS OF GOLD 198 IRIDIUM 192 CESIUM 137 RADIUM 226 AND COBALT 60
    MEISBERGER, LL
    KELLER, RJ
    SHALEK, RJ
    [J]. RADIOLOGY, 1968, 90 (05) : 953 - +
  • [18] ATTENUATION AND SCATTERING IN A PHANTOM OF GAMMA RAYS FROM SOME RADIONUCLIDES USED IN MOULD AND INTERSTITIAL GAMMA-RAY THERAPY
    MEREDITH, WJ
    GREENE, D
    KAWASHIMA, K
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1966, 39 (460) : 280 - +
  • [19] ANISOTROPY FUNCTIONS FOR PD-103, I-125, AND IR-192 INTERSTITIAL BRACHYTHERAPY SOURCES
    NATH, R
    MEIGOONI, AS
    MUENCH, P
    MELILLO, A
    [J]. MEDICAL PHYSICS, 1993, 20 (05) : 1465 - 1473
  • [20] DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43
    NATH, R
    ANDERSON, LL
    LUXTON, G
    WEAVER, KA
    WILLIAMSON, JF
    MEIGOONI, AS
    [J]. MEDICAL PHYSICS, 1995, 22 (02) : 209 - 234