Simple and sensitive protein detection system using UV LEDs and liquid core waveguides - art. no. 675505

被引:5
作者
Belz, Mathias [1 ]
机构
[1] World Precis Instruments Inc, Sarasota, FL 34240 USA
来源
ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES V | 2007年 / 6755卷
关键词
UV-LED; liquid core waveguide; optical fiber;
D O I
10.1117/12.735348
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Protein concentrations are traditionally analyzed in the ultraviolet at 280nm using laboratory spectrophotometers. Recently, AlGaN/GaN deep ultraviolet Light Emitting Diodes (LED) became available in the 250 nm to 350 nm wavelength region. An inexpensive fiber optic detection system based on these UV LEDs and photodiodes has been developed. Measurement stability, noise and drift will be discussed. To improve sensitivity of the detection system, microliter volume liquid core waveguide sampling cells with 10 cm and 50 cm pathlength were evaluated. With a continuous flow setup, protein concentrations as low as 1 mu g/mL and 0.2 mu g/mL were detectable in a 10 cm and a 50 cm pathlength cell respectively, based on a 10 mAU absorbance signal and a signal to noise ratio greater than 10.
引用
收藏
页码:75505 / 75505
页数:8
相关论文
共 16 条
  • [1] Liquid core waveguide with fiber optic coupling for remote pollution monitoring in the deep ultraviolet
    Belz, M
    Dress, P
    Klein, KF
    Boyle, WJO
    Franke, H
    Grattan, KTV
    [J]. WATER SCIENCE AND TECHNOLOGY, 1998, 37 (12) : 279 - 284
  • [2] Linearity and effective optical pathlength of liquid waveguide capillary cells.
    Belz, M
    Dress, P
    Sukhitskiy, A
    Liu, S
    [J]. INTERNAL STANDARDIZATION AND CALIBRATION ARCHITECTURES FOR CHEMICAL SENSORS, 1999, 3856 : 271 - 281
  • [3] BELZ M, 2006, P SPIE, V637
  • [4] BELZ M, 2007, P IOP CIT U LOND UK
  • [5] UV LED fiber optic detection system for DNA and protein
    Belz, Mathias
    Klein, Felix A.
    Habliegger, Heidi
    [J]. OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS VII, 2007, 6433
  • [6] Physical analysis of teflon coated capillary waveguides
    Dress, P
    Belz, M
    Klein, KF
    Grattan, KTV
    Franke, H
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) : 278 - 284
  • [7] GLASEL JA, 1995, BIOTECHNIQUES, V18, P62
  • [8] REMOTE, LONG-PATHLENGTH CELL FOR HIGH-SENSITIVITY RAMAN-SPECTROSCOPY
    SCHWAB, SD
    MCCREERY, RL
    [J]. APPLIED SPECTROSCOPY, 1987, 41 (01) : 126 - 130
  • [9] LONG CAPILLARY CELL WITH THE USE OF SUCCESSIVE TOTAL REFLECTION AT OUTER CELL-SURFACE FOR LIQUID ABSORPTION SPECTROMETRY
    TSUNODA, K
    NOMURA, A
    YAMADA, J
    NISHI, S
    [J]. ANALYTICAL SCIENCES, 1988, 4 (03) : 321 - 323
  • [10] THE POSSIBILITY OF SIGNAL ENHANCEMENT IN LIQUID ABSORPTION SPECTROMETRY WITH A LONG CAPILLARY CELL UTILIZING SUCCESSIVE TOTAL REFLECTION AT THE OUTER CELL-SURFACE
    TSUNODA, K
    NOMURA, A
    YAMADA, J
    NISHI, S
    [J]. APPLIED SPECTROSCOPY, 1989, 43 (01) : 49 - 55