A Comparison of Forearm Supination and Elbow Flexion Strength in Patients With Long Head of the Biceps Tenotomy or Tenodesis

被引:84
作者
Shank, John R. [2 ]
Singleton, Steven B. [2 ]
Braun, Sepp [4 ]
Kissenberth, Michael J. [2 ]
Ramappa, Arun [3 ]
Ellis, Henry [4 ]
Decker, Michael J. [4 ]
Hawkins, Richard J. [2 ]
Torry, Michael R. [1 ,4 ]
机构
[1] Illinois State Univ, Sch Kinesiol & Recreat, Coll Appl Sci & Technol, Normal, IL 61761 USA
[2] Steadman Hawkins Clin Carolinas, Spartanburg, SC USA
[3] Harvard Univ, Beth Israel Deaconess Med Ctr, Dept Orthopaed, Sch Med, Boston, MA 02215 USA
[4] Steadman Philippon Res Inst, Biomech Res Lab, Vail, CO USA
关键词
ELECTROMYOGRAPHIC ANALYSIS; SHOULDER; TENDON; BRACHII; MUSCLE;
D O I
10.1016/j.arthro.2010.06.022
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to compare the forearm supination and elbow flexion strength of the upper extremity in patients who have had an arthroscopic long head of the biceps tendon (LHBT) release with patients who have had an LHBT tenodesis. Methods: Cybex isokinetic strength testing (Cybex Division of Lumex, Ronkonkoma, NY) was performed on 17 patients who underwent arthroscopic LHBT tenotomy, 19 patients who underwent arthroscopic LHBT tenodesis, and 31 age-, gender-, and body mass index-matched control subjects. Subjects were considered fully recovered from shoulder surgery, were released for unrestricted activities, and were at least 6 months after surgery before testing. Subjects were tested for forearm supination and elbow flexion strength of both arms by use of a Cybex II NORM isokinetic dynamometer at 60 degrees/s and 120 degrees/s. Testing was performed on injured and uninjured arms as well as dominant and nondominant arms in control subjects. Both forearm supination and elbow flexion strength values were recorded. Results: Comparison between the involved and uninvolved upper extremities within each group by use of a paired t test showed a 7% increase in elbow flexion strength when the dominant and nondominant arms were compared at 60 degrees/s. Neither the tenotomy nor tenodesis groups exhibited elbow flexion strength differences at 120 degrees/s (all P >= .147). Comparison between groups by use of 2 x 3 analysis of variance (speed x group) showed no statistical difference in either forearm supination or elbow flexion strength when we compared the tenotomy, tenodesis, and control groups. Conclusions: In asymptomatic patients who have had biceps tenotomy or tenodesis, no statistically significant forearm supination or elbow flexion strength differences existed in the involved extremity between the 2 study groups. Level of Evidence: Level III, case-control study.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 24 条
[1]  
Ball C., 2001, TECH SHOULDER ELBOW, V2, P140, DOI [10.1097/00132589-200109000-00002, DOI 10.1097/00132589-200109000-00002]
[2]   How would you treat the partially torn biceps tendon? [J].
Barber, FA .
ARTHROSCOPY, 2001, 17 (06) :636-637
[3]   Arthroscopic biceps tenodesis: A new technique using bioabsorbable interference screw fixation [J].
Boileau, P ;
Krishnan, SG ;
Coste, JS ;
Walch, G .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (09) :1002-1012
[4]  
*CYB DIV LUM, 1982, IS JOINT TEST EX HDB
[5]  
Eakin C L, 1999, J Am Acad Orthop Surg, V7, P300
[6]   Results of biceps tenotomy for treatment of pathology of the long head of the biceps brachii [J].
Gill, TJ ;
McIrvin, E ;
Mair, SD ;
Hawkins, RJ .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2001, 10 (03) :247-249
[7]   DYNAMIC ELECTROMYOGRAPHIC ANALYSIS OF THE THROWING SHOULDER WITH GLENOHUMERAL INSTABILITY [J].
GLOUSMAN, R ;
JOBE, F ;
TIBONE, J ;
MOYNES, D ;
ANTONELLI, D ;
PERRY, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (02) :220-226
[8]   AN EMG ANALYSIS OF THE SHOULDER IN PITCHING .2. [J].
JOBE, FW ;
MOYNES, DR ;
TIBONE, JE ;
PERRY, J .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1984, 12 (03) :218-220
[9]   Arthroscopic release of the long head of the biceps tendon - Functional outcome and clinical results [J].
Kelly, AM ;
Drakos, MC ;
Fealy, S ;
Taylor, SA ;
O'Brien, SJ .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (02) :208-213
[10]  
KUMAR VP, 1989, CLIN ORTHOP RELAT R, P172