Side-by-side comparability of batch and continuous downstream for the production of monoclonal antibodies

被引:25
作者
David, Laura [1 ]
Schwan, Peter [2 ]
Lobedann, Martin [2 ]
Borchert, Sven-Oliver [2 ]
Budde, Bastian [2 ]
Temming, Maike [2 ]
Kuerschner, Mike [2 ]
Aguilo, Francisca Maria Alberti [2 ]
Baumarth, Kerstin [2 ]
Thuete, Tobias [2 ]
Maiser, Benjamin [2 ]
Blank, Andreas [2 ]
Kistler, Viktorija [2 ]
Weber, Nils [2 ]
Brandt, Heiko [2 ]
Poggel, Martin [2 ]
Kaiser, Klaus [2 ]
Geisen, Karl [2 ]
Oehme, Felix [2 ]
Schembecker, Gerhard [3 ]
机构
[1] Invite GmbH, Chempk,Geb W32, D-51368 Leverkusen, Germany
[2] Bayer AG, Leverkusen, Germany
[3] TU Dortmund Univ, Plant & Proc Design, BCI, Dortmund, Germany
关键词
continuous processing; DSP; mAb; side-by-side comparability; METHIONINE OXIDATION;
D O I
10.1002/bit.27267
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Continuous processing is the future production method for monoclonal antibodies (mAbs). A fully continuous, fully automated downstream process based on disposable equipment was developed and implemented inside the MoBiDiK pilot plant. However, a study evaluating the comparability between batch and continuous processing based on product quality attributes was not conducted before. The work presented fills this gap comparing both process modes experimentally by purifying the same harvest material (side-by-side comparability). Samples were drawn at different time points and positions in the process for batch and continuous mode. Product quality attributes, product-related impurities, as well as process-related impurities were determined. The resulting polished material was processed to drug substance and further evaluated regarding storage stability and degradation behavior. The in-process control data from the continuous process showed the high degree of accuracy in providing relevant process parameters such as pH, conductivity, and protein concentration during the entire process duration. Minor differences between batch and continuous samples are expected as different processing conditions are unavoidable due to the different nature of batch and continuous processing. All tests revealed no significant differences in the intermediates and comparability in the drug substance between the samples of both process modes. The stability study of the final product also showed no differences in the stability profile during storage and forced degradation. Finally, online data analysis is presented as a powerful tool for online-monitoring of chromatography columns during continuous processing.
引用
收藏
页码:1024 / 1036
页数:13
相关论文
共 18 条
[1]  
Bernshausen J, 2016, Patent No. [BR112017024373 (A2), 112017024373]
[2]  
BioPhorum, 2019, CONT DOWNSTR PROC BI
[3]  
Bisschops M., 2009, Bioprocess Int, P18, DOI DOI 10.1021/BP049692B
[4]   Online integrity monitoring in the Protein A step of mAb Production Processes-increasing reliability and process robustness [J].
Bork, Christopher ;
Holdridge, Sarah ;
Walter, Mark ;
Fallon, Eric ;
Pohlscheidt, Michael .
BIOTECHNOLOGY PROGRESS, 2014, 30 (02) :383-390
[5]   Information Technologies for Innovative Process and Plant Design [J].
Bramsiepe, Christian ;
Krasberg, Nicolai ;
Fleischer, Christoph ;
Hohmann, Lukas ;
Kockmann, Norbert ;
Schembecker, Gerhard .
CHEMIE INGENIEUR TECHNIK, 2014, 86 (07) :966-981
[6]   Comparison of methionine oxidation in thermal stability and chemically stressed samples of a fully human monoclonal antibody [J].
Churnsae, Chris ;
Gaza-Bulseco, Georgeen ;
Sun, Joanne ;
Liu, Hongcheng .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2) :285-294
[7]   Continuous viral filtration for the production of monoclonal antibodies [J].
David, Laura ;
Niklas, Jens ;
Budde, Bastian ;
Lobedann, Martin ;
Schembecker, Gerhard .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2019, 152 :336-347
[8]   Simulation of pH level distribution inside a coiled flow inverter for continuous low pH viral inactivation [J].
David, Laura ;
Waldschmidt, Lisa Marie ;
Lobedann, Martin ;
Schembecker, Gerhard .
BIOTECHNOLOGY AND BIOENGINEERING, 2020, 117 (02) :429-437
[9]   Virus study for continuous low pH viral inactivation inside a coiled flow inverter [J].
David, Laura ;
Maiser, Benjamin ;
Lobedann, Martin ;
Schwan, Peter ;
Lasse, Michael ;
Ruppach, Horst ;
Schembecker, Gerhard .
BIOTECHNOLOGY AND BIOENGINEERING, 2019, 116 (04) :857-869
[10]   Charge variants in IgG1 Isolation, characterization, in vitro binding properties and pharmacokinetics in rats [J].
Khawli, Leslie A. ;
Goswami, Sirj ;
Hutchinson, Ryan ;
Kwong, Zephania W. ;
Yang, Jihong ;
Wang, Xiangdan ;
Yao, Zhenling ;
Sreedhara, Alavattam ;
Cano, Tony ;
Tesar, Devin ;
Nijem, Ihsan ;
Allison, David E. ;
Wong, Pin Yee ;
Kao, Yung-Hsiang ;
Quan, Cynthia ;
Joshi, Amita ;
Harris, Reed J. ;
Motchnik, Paul .
MABS, 2010, 2 (06) :613-624