Accuracy and precision of compartmental model parameters obtained from directly estimated dynamic SPECT time-activity curves

被引:0
作者
Reutter, BW [1 ]
Gullberg, GT [1 ]
Huesman, RH [1 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Dept Nucl Med & Funct Imaging, Berkeley, CA 94720 USA
来源
2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3 | 2003年
关键词
dynamic single photon emission computed tomography (SPECT); fully four-dimensional (4-13) reconstruction; kinetic parameter estimation;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Quantitative kinetic analysis of dynamic cardiac single photon emission computed tomography (SPECT) data has the potential to provide better contrast between healthy and diseased tissue, compared to static images. However, imaging a rapidly changing radiopharmaceutical distribution with the use of a moving gantry yields inconsistent projection data that can generate artifacts in a time sequence of conventional image reconstructions. The artifacts can lead to biases in kinetic parameters estimated from the image sequence. This source of bias can be eliminated by estimating B-spline models for time-activity curves directly from the projections. In this study, we perform Monte Carlo simulations to determine how the polynomial order and initial time sampling of the splines affect the accuracy and precision of compartmental model parameters obtained from directly estimated time-activity curves. The Mathematical Cardiac Torso (MCAT) phantom is used to simulate a realistic 15 min dynamic Tc-99m-teboroxime patient study in which 10 million total events are detected. For a large volume of normal myocardium (250 cc), the relative bias of the uptake and washout parameter sample means does not exceed 0.22% when using cubic or quadratic splines that provide rapid initial sampling. The coefficient of variation is about 1%. For small (8.4 cc) myocardial defects that exhibit reduced uptake and accelerated washout, the relative bias and coefficient of variation increase to maximum values of about 16% and 49%, respectively. These levels of accuracy and precision allow the defects to be discriminated from the normal myocardium.
引用
收藏
页码:1584 / 1588
页数:5
相关论文
共 16 条
[1]  
BARTELS R. H., 1987, INTRO SPLINES USE CO
[2]   Compartmental modeling of technetium-99m-labeled teboroxime with dynamic single-photon emission computed tomography - Comparison with static thallium-201 in a canine model [J].
Di Bella, EVR ;
Ross, SG ;
Kadrmas, DJ ;
Khare, HS ;
Christian, PE ;
McJames, S ;
Gullberg, GT .
INVESTIGATIVE RADIOLOGY, 2001, 36 (03) :178-185
[3]   The incorporation of organ uptake into dynamic SPECT (dSPECT) image reconstruction [J].
Farncombe, T ;
Celler, A ;
Bever, C ;
Noll, D ;
Maeght, J ;
Harrop, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) :3-9
[4]  
GULLBERG GT, 1999, NUCL CARDIOLOGY STAT, P137
[5]   Kinetic parameter estimation from SPECT cone-beam projection measurements [J].
Huesman, RH ;
Reutter, BW ;
Zeng, GL ;
Gullberg, GT .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) :973-982
[6]  
HUESMAN RH, 1995, LBL37621
[7]   4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior [J].
Kadrmas, DJ ;
Gullberg, GT .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) :1553-1574
[8]   Optimal time-activity basis selection for exponential spectral analysis: Application to the solution of large dynamic emission tomographic reconstruction problems [J].
Maltz, JS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) :1452-1464
[9]  
NARRA RK, 1992, J NUCL MED, V33, P88
[10]  
Nichols TE, 1999, LECT NOTES COMPUT SC, V1613, P98