1-(2-Pyridylazo)-2-Naphthol Entrapped Polyacrylamide Hydrogels: Detection of Copper Ions in Water

被引:1
作者
Kumar, Rajesh [1 ]
Verma, Sunita [1 ]
Kachwaha, Meenakshi [1 ]
机构
[1] Water Qual Management Grp, Desert Environm Sci & Technol Div, Def Lab, Jodhpur 342011, Rajasthan, India
关键词
hydrogel; detection; copper ion; naked eye; UV-Visible; SPECTROPHOTOMETRIC DETERMINATION; TRACE COPPER; LEAD;
D O I
10.3103/S1063455X2104007X
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A colorimetric material was prepared and evaluated for simple and rapid detection of copper ion and other toxic metal ions. In this study, a colorimetric 1-(2-pyridylazo)-2-naphthol entrapped polyacrylamide (PAN-PAA) hydrogels was successfully prepared through polymerization and characterized by FT-IR. PAN-PAA hydrogels were evaluated for naked eye detection of Cu(II) ions in water. A yellow colour solution change into pink visual colour was observed within 20 min when hydrogel treated with Cu(II) ions at 300 mu g L-1 (ppb). The colour ntensity increased with increasing concentration of Cu(II) ions. The reaction time of colour change observed less time when concentration of metal ion is increasing such as1 mg L-1 (15 min), 2 mg L-1 (10 min) and 3 mg L-1 (5 min). UV-visible spectra of PAN-PAA hydrogel shows absorbance at wavelength 560 nm with copper ions without interference of other metal ions viz. Cd(II), Co(II), Ni(II), Fe(II), Hg(II) and Pb(II). The hydrogels can be regenerated with 1 N HCl after reaction of Cu(II) ions. In conclusion, PAN-PAA hydrogel can be used as a potential colorimetric material for detection of Cu(II) ions in water. Colorimetric methods have their own advantages such as simplicity, high sensitivity and a short response time. In particular, these methods can be monitored by the naked eye and potential application in on-site detection owing to their simplicity and potability.
引用
收藏
页码:330 / 335
页数:6
相关论文
共 22 条
[1]   SPECTRUM OF POISONING REQUIRING HEMODIALYSIS IN A TERTIARY CARE HOSPITAL IN INDIA [J].
AGARWAL, SK ;
TIWARI, SC ;
DASH, SC .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (01) :20-22
[2]  
[Anonymous], 2004, WHO Guidelines for Drinkingwater Quality
[3]  
Bannon DI, 2001, CLIN CHEM, V47, P1703
[4]   Copper toxicity in the general population [J].
Brewer, George J. .
CLINICAL NEUROPHYSIOLOGY, 2010, 121 (04) :459-460
[5]  
[Eaton A.D. American Public Health Association (APHA) American Water Works Association (AWWA) and Water Environment Foundation (WEF) American Public Health Association (APHA) American Water Works Association (AWWA) and Water Environment Foundation (WEF)], 2012, Standard Methods for the examination of water and wastewater, V20th
[6]   Analysis of waste water by x-ray fluorescence spectrometry [J].
Eksperiandova, LP ;
Blank, AB ;
Makarovskaya, YN .
X-RAY SPECTROMETRY, 2002, 31 (03) :259-263
[7]  
KUMAR B, 1991, MIKROCHIM ACTA, V3, P79
[8]   SPECTROPHOTOMETRIC DETERMINATION OF TRACE COPPER WITH A CU-DIETHYLDITHIOCARBAMATE-BETA-CYCLODEXTRIN COLOR SYSTEM [J].
LI, SH ;
LI, SQ ;
CHEN, AJ .
TALANTA, 1993, 40 (07) :1085-1090
[9]   Determination of cadmium, mercury and lead in seawater by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry [J].
Liu, HW ;
Jiang, SJ ;
Liu, SH .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (09) :1367-1375
[10]   A HIGHLY SENSITIVE COLORIMETRIC DETERMINATION OF SERUM COPPER USING ALPHA,BETA,GAMMA,DELTA-TETRAKIS(4-N-TRIMETHYLAMINOPHENYL)-PORPHINE [J].
MAKINO, T ;
ITOH, JI .
CLINICA CHIMICA ACTA, 1981, 111 (01) :1-8