Fast microtomography using high energy synchrotron radiation -: art. no. 043702

被引:144
作者
Di Michiel, M [1 ]
Merino, JM
Fernandez-Carreiras, D
Buslaps, T
Honkimäki, V
Falus, P
Martins, T
Svensson, O
机构
[1] European Synchrotron Radiat Facil, F-38000 Grenoble, France
[2] Univ Autonoma Madrid, Dept Fis Aplicada, E-28049 Madrid, Spain
[3] Inst Max Von Laue Paul Langevin, F-38000 Grenoble, France
基金
美国国家科学基金会;
关键词
D O I
10.1063/1.1884194
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
At the High Energy Beamline ID15A at the European Synchrotron Radiation Facility we have developed a fast three-dimensional x-ray microtomography system, which acquires a complete dataset in typically less than 10 s. This unprecedented speed is achieved by combining a high efficiency phosphor screen, a reflecting microscope objective and a fast charge coupled device detector with the very intense high-energy white beam radiation provided by a wiggler source. The achieved spatial resolution is 2 mu m. The available x-ray energy spectrum spans from 20 to 250 keV and can therefore be used for low and high Z materials. The spectrum can be modified by inserting different filters into the x-ray beam in order to optimize the signal-to-noise ratio and to avoid beam-hardening artifacts. Different phosphors with different energy sensitivity can be used. The very high speed allows in situ studies of systems evolving on the time scale of a few seconds or minutes. Three examples are given on sintering of metallic powders, solidification of binary alloys and liquid front propagation in granular materials. (C) American Institute of Physics.
引用
收藏
页数:7
相关论文
共 21 条
  • [1] Microtomography using synchrotron radiation as a user experiment at beamlines BW2 and BW5 of HASYLAB at DESY
    Beckmann, F
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 34 - 41
  • [2] X-ray computed microtomography (mu CT) using synchrotron radiation (SR)
    Bonse, U
    Busch, F
    [J]. PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 1996, 65 (1-2) : 133 - 169
  • [3] Phase objects in synchrotron radiation hard x-ray imaging
    Cloetens, P
    Barrett, R
    Baruchel, J
    Guigay, JP
    Schlenker, M
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (01) : 133 - 146
  • [4] Observation of microstructure and damage in materials by phase sensitive radiography and tomography
    Cloetens, P
    PateyronSalome, M
    Buffiere, JY
    Peix, G
    Baruchel, J
    Peyrin, F
    Schlenker, M
    [J]. JOURNAL OF APPLIED PHYSICS, 1997, 81 (09) : 5878 - 5886
  • [5] Fast CCD camera for x-ray photon correlation spectroscopy and time-resolved x-ray scattering and imaging
    Falus, P
    Borthwick, MA
    Mochrie, SGJ
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (11) : 4383 - 4400
  • [6] OPTIMUM ENERGIES FOR X-RAY TRANSMISSION TOMOGRAPHY OF SMALL SAMPLES - APPLICATIONS OF SYNCHROTRON RADIATION TO COMPUTERIZED-TOMOGRAPHY .1.
    GRODZINS, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03): : 541 - 545
  • [7] HERMAN GT, 1980, IMAGE RECONSTRUCTION
  • [8] KAK AC, 1988, PRINCIPLES COMPUTERI, P186
  • [9] X-ray imaging with submicrometer resolution employing transparent luminescent screens
    Koch, A
    Raven, C
    Spanne, P
    Snigirev, A
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (07): : 1940 - 1951
  • [10] X-ray camera for computed microtomography of biological samples with micrometer resolution using Lu3Al5O12 and Y3Al5O12 scintillations
    Koch, A
    Peyrin, F
    Heurtier, P
    Ferrand, B
    Chambaz, B
    Ludwig, W
    Couchaud, M
    [J]. MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 170 - 179