Concurrent Flame Spread Over Two-Sided Thick PMMA Slabs in Microgravity

被引:5
作者
Olson, Sandra L. [1 ]
Urban, David L. [1 ]
Ruff, Gary A. [1 ]
Ferkul, Paul, V [2 ]
Toth, Balazs [3 ]
Eigenbrod, Christian [4 ]
Meyer, Florian [4 ]
Jomaas, Grunde [5 ]
机构
[1] NASA, Glenn Res Ctr, Cleveland, OH 44135 USA
[2] NASA, USRA, Glenn Res Ctr, Cleveland, OH 44135 USA
[3] European Space Agcy, Postbus 299, NL-2200 AG Noordwijk, Netherlands
[4] Univ Bremen, ZARM, D-28359 Bremen, Germany
[5] Univ Edinburgh, Sch Engn, Edinburgh EH9 3FG, Midlothian, Scotland
基金
美国国家航空航天局;
关键词
Concurrent flame spread; Microgravity; PMMA; Thermally thick; SOUNDING ROCKET;
D O I
10.1007/s10694-019-00863-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Spacecraft fire safety is an important consideration when designing future exploration missions. Concurrent flow flame spread experiments were carried out aboard the Cygnus spacecraft while in orbit to address current knowledge gaps related to solid fuel combustion in microgravity. The experiments used PMMA (polymethylmethacrylate) samples that were 50 mm wide and 290 mm long with two variations-one sample was a 10 mm thick flat slab, while the other was a 10 mm thick flat sample that had a 4 mm thick grooved center section. The thickness variation had a major impact on the flame shape, and the grooved sample developed a deep inverted-V shaped notch as the thin center section burned through. This notch enhanced heat transfer from the flame to the solid through an effectively wider flame base, which is the part of the flame with the highest temperature. Unlike in normal gravity (and also likely in partial gravity), where buoyant flow promotes acceleratory upward flame growth, the microgravity flames reached a steady size (limiting length) for a fixed forced convective flow in agreement with theory (i.e. there is a zero net heat flux at the flame tip). The limiting length implies that the spread rate of the flame will be controlled by the regression rate (burnout rate) of the material because the flames remains anchored to the upstream end of the fuel samples. This is a significant finding for spacecraft fire safety, and makes the probability of flashover in a spacecraft unlikely as the flame size will be small for low convective ventilation flow environments typical in spacecraft. On the other hand, long-burning flames in small vehicles will generate significant quantities of fuel vapor that may reach the lean flammability limit and cause a backdraft. The rapid extinction of the flame when the flow was turned off also supports the existing fire mitigation strategy on the ISS to deactivate the ventilation system in the event of fire alarm. These findings can be applied to improve the safety of future space exploration missions.
引用
收藏
页码:49 / 69
页数:21
相关论文
共 29 条
  • [1] Altenkirch RA, 1998, TWENTY-SEVENTH SYMPOSIUM (INTERNATIONAL) ON COMBUSTION, VOLS 1 AND 2, P2515
  • [2] [Anonymous], 2016, NASASTD6001B
  • [3] Chao YH, 1993, ASME PUBLICATIONS HT, V199, P135
  • [4] Creeping flame spread along fuel cylinders in forced and natural flows and microgravity
    Delichatsios, MA
    Altenkirch, RA
    Bundy, MF
    Bhattacharjee, S
    Tang, L
    Sacksteder, K
    [J]. PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2000, 28 : 2835 - 2842
  • [5] NEAR LIMIT FLAME SPREAD OVER THICK FUELS IN A CONCURRENT FORCED FLOW
    DIBLASI, C
    CRESCITELLI, S
    RUSSO, G
    [J]. COMBUSTION AND FLAME, 1988, 72 (02) : 205 - 215
  • [6] ECSS 5, 2010, ECSSQST7021C ECSS ES
  • [7] Eigenbrod C, 2017, 47 INT C ENV SYST IC
  • [8] Ferkul P., 2017, 47 INT C ENV SYST CH
  • [9] Ferkul P, 1999, 37 AER SCI M EXH, P439
  • [10] CONTROLLING MECHANISMS OF FLAME SPREAD
    FERNANDEZPELLO, AC