Coronary artery disease: Myocardial perfusion MR imaging with sensitivity encoding versus conventional angiography

被引:93
作者
Plein, S
Radjenovic, A
Ridgway, JP
Barmby, D
Greenwood, JP
Ball, SG
Sivananthan, MU
机构
[1] Gen Infirm, BHF Cardiac Magnet Resonance Unit, Leeds LS1 3EX, W Yorkshire, England
[2] Gen Infirm, Dept Med Phys, Leeds LS1 3EX, W Yorkshire, England
[3] Univ Leeds, Inst Cardiovasc Res, Leeds, W Yorkshire, England
关键词
D O I
10.1148/radiol.2352040454
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the technical performance of sensitivity encoding (SENSE)accelerated myocardial perfusion magnetic resonance (MR) imaging and prospectively assess the diagnostic accuracy of this examination for depiction of significant coronary artery disease (CAD). MATERIALS AND METHODS: All 102 subjects provided written informed consent, and the local ethics committee approved the study. A saturation-recovery segmented k-space gradient-echo pulse sequence was combined with SENSE to allow dynamic acquisition of myocardial perfusion data on four parallel short-axis MR image sections at every heartbeat. This technique was evaluated in 10 healthy volunteers and in 92 patients scheduled to undergo conventional coronary angiography. Gadopentetate dimeglumine was peripherally injected at rest and during adenosine-induced stress. The maximal upslope of the signal intensity-time profiles was plotted for 16 myocardial segments defined on three MR image sections, and a myocardial perfusion reserve index (MPRI) between stress and rest, normalized to the input function from the blood pool of the most basal section, was calculated. Areas under receiver operating characteristic curves (AUCs) were used to assess the diagnostic performance of cardiac MR imaging for depiction of greater than 70% CAD seen at coronary angiography, the reference standard. RESULTS: In volunteers, the mean myocardial enhancement was 2.1 +/- 1.2 (standard deviation), with homogeneous signal intensity distribution across the segments. The diagnostic accuracy of MPRI measurements was high (AUC, 0.908; sensitivity, 88% [52 of 59 patients]; specificity, 82% [27 of 33 patients]). Diagnostic performance was similar among separate analyses of the three coronary territories and among separate analyses of data in the patients with diabetes mellitus, left ventricular hypertrophy, or myocardial infarction. CONCLUSION: Multisection myocardial perfusion MR imaging with SENSE is feasible and has high diagnostic accuracy in the detection of CAD. (C) RSNA, 2005.
引用
收藏
页码:423 / 430
页数:8
相关论文
共 24 条
[1]   Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance [J].
Al-Saadi, N ;
Nagel, E ;
Gross, M ;
Bornstedt, A ;
Schnackenburg, B ;
Klein, C ;
Klimek, W ;
Oswald, H ;
Fleck, E .
CIRCULATION, 2000, 101 (12) :1379-1383
[2]   Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences [J].
Alfakih, K ;
Plein, S ;
Thiele, H ;
Jones, T ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :323-329
[3]   1ST-PASS CARDIAC PERFUSION - EVALUATION WITH ULTRAFAST MR IMAGING [J].
ATKINSON, DJ ;
BURSTEIN, D ;
EDELMAN, RR .
RADIOLOGY, 1990, 174 (03) :757-762
[4]   Magnetic resonance myocardial first-pass perfusion imaging: Parameter optimization for signal response and cardiac coverage [J].
Bertschinger, KM ;
Nanz, D ;
Buechi, M ;
Luescher, TF ;
Marincek, B ;
von Schulthess, GK ;
Schwitter, J .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) :556-562
[5]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[6]  
Chia JM, 2000, J MAGN RESON IMAGING, V12, P678, DOI 10.1002/1522-2586(200011)12:5<678::AID-JMRI4>3.0.CO
[7]  
2-5
[8]   QUANTIFICATION OF MYOCARDIAL BLOOD-FLOW AND EXTRACELLULAR VOLUMES USING A BOLUS INJECTION OF GD-DTPA - KINETIC MODELING IN CANINE ISCHEMIC DISEASE [J].
DIESBOURG, LD ;
PRATO, FS ;
WISENBERG, G ;
DROST, DJ ;
MARSHALL, TP ;
CARROLL, SE ;
ONEILL, B .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :239-253
[9]   Capillary transfer constant of Gd-DTPA in the myocardium at rest and during vasodilation assessed by MRI [J].
Fritz-Hansen, T ;
Rostrup, E ;
Sondergaard, L ;
Ring, PB ;
Amtorp, O ;
Larsson, HBW .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :922-929
[10]   Assessment of coronary flow reserve:: Comparison between contrast-enhanced magnetic resonance imaging and positron emission tomography [J].
Ibrahim, T ;
Nekolla, SG ;
Schreiber, K ;
Odaka, K ;
Volz, S ;
Mehilli, J ;
Güthlin, M ;
Delius, W ;
Schwaiger, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) :864-870