Fault Diagnosis for Sensors in HVAC Systems Using Wavelet Neural Network

被引:0
作者
Du, Zhimin [1 ]
Jin, Xinqiao [1 ]
Fan, Bo [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai 200240, Peoples R China
来源
ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING | 2009年
关键词
wavelet analysis; neural network; fault diagnosis; sensor; HVAC; AIR-CONDITIONING SYSTEMS; TOLERANT CONTROL; TEMPERATURE;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Various sensor faults in heating, ventilation and air conditioning (HVAC) systems usually result in more energy consumption or poor indoor air quality. Generally, two fault detection and diagnosis methods have been developed and widely applied in HVAC systems. One is the model-based, and the other is the data-driven. Each of these two methods has its own characteristic and application condition. The model-based method deeply relies on the accuracy of the mathematic model built. While the data-driven approach requires excellent training data. In this paper, wavelet neural network, which combines the wavelet analysis and neural network, is presented to diagnose the fixed and drifting biases of sensors in the HVAC systems. Wavelet analysis is employed to process measurement. data to obtain the eigenvector matrix representing the operation characteristic information of the system through decomposing the original data. Neural network, which is well trained to learn various conditions using the eigenvectors, is used to diagnose the sensor faults. Simulation tests in this paper illustrate that wavelet neural network can successfully diagnose fixed and drifting biases of sensors in HVAC systems.
引用
收藏
页码:409 / 415
页数:7
相关论文
共 21 条
  • [1] Flow meter fault isolation in building central chilling systems using wavelet analysis
    Chen, YM
    Hao, XL
    Zhang, GQ
    Wang, SW
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (13-14) : 1700 - 1710
  • [2] COMSTOCK MC, 2001, H69920 PURD U
  • [3] Fault diagnosis in air-conditioning systems: A multi-step fuzzy model-based approach
    Dexter, AL
    Ngo, D
    [J]. HVAC&R RESEARCH, 2001, 7 (01): : 83 - 102
  • [4] DEXTER AL, 2001, 34 ANNEX
  • [5] PCA-FDA-based fault diagnosis for sensors in VAV systems
    Du, Zhimin
    Jin, Xinqiao
    Wu, Lizhou
    [J]. HVAC&R RESEARCH, 2007, 13 (02): : 349 - 367
  • [6] Detection and diagnosis for sensor fault in HVAC systems
    Du, Zhimin
    Jin, Xinqiao
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (03) : 693 - 702
  • [7] HYVARNEN J, 1995, 25 IEA ANNEX
  • [8] Fault tolerant control of outdoor air and AHU supply air temperature in VAV air conditioning systems using PICA method
    Jin, Xinqiao
    Du, Zhimin
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (11-12) : 1226 - 1237
  • [9] Katipamula S., 2003, P 2003 INT C ENH BUI
  • [10] Lee WY, 1997, ASHRAE TRAN, V103, P621