Three-dimensional analysis of trickle flow hydrodynamics: Computed tomography image acquisition and processing

被引:13
作者
van der Merwe, Werner [1 ]
Nicol, Willie [1 ]
de Beer, FriUie [2 ]
机构
[1] Univ Pretoria, Dept Chem Engn, ZA-0002 Pretoria, South Africa
[2] AAR&RS Grp, ZA-0001 Pretoria, South Africa
关键词
multiphase flow; hydrodynamics; tomography; imaging; hydrodynamic multiplicity; trickle flow;
D O I
10.1016/j.ces.2007.08.009
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Computed tomography (CT) is a powerful technique that can be used to image multi-phase flow in three dimensions. In this study, X-ray CT is used to image trickle flow in a stationary packed bed with a spatial resolution of 118 mu m/pixel. Errors introduced during the radiograph acquisition and tomographic reconstruction of the volume image make it difficult to identify the three phases (gas, liquid and solid) and in particular the interfacial areas. A novel post-processing strategy based on the matrix convolution operation and a priori knowledge of the shape of the particles is developed that makes it possible to accurately identify the phase interfaces in an unbiased way. The result is a ternary three-dimensional image where each voxel is one of gas, liquid or solid. From this, the gas-liquid, gas-solid and liquid-solid interfacial areas can be calculated. The proposed procedure yields images that are superior to those obtained from the usually employed thresholding operation. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:7233 / 7244
页数:12
相关论文
共 20 条
[1]   Hydrodynamics in two-phase flow within porous media [J].
Anadon, LD ;
Lim, MHM ;
Sederman, AJ ;
Gladden, LF .
MAGNETIC RESONANCE IMAGING, 2005, 23 (02) :291-294
[2]   Local liquid holdups and hysteresis in a 2-D packed bed using X-ray radiography [J].
Basavaraj, MG ;
Gupta, GS ;
Naveen, K ;
Rudolph, V ;
Bali, R .
AICHE JOURNAL, 2005, 51 (08) :2178-2189
[3]   Measurement of liquid flow distribution in trickle bed reactor of large diameter with a new gamma-ray tomographic system [J].
Boyer, C ;
Fanget, B .
CHEMICAL ENGINEERING SCIENCE, 2002, 57 (07) :1079-1089
[5]   Noninvasive tomographic and velocimetric monitoring of multiphase flows [J].
Chaouki, J ;
Larachi, F ;
Dudukovic, MP .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1997, 36 (11) :4476-4503
[6]   Characteristics of the neutron/X-ray tomography system at the SANRAD facility in South Africa [J].
de Beer, FC .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 542 (1-3) :1-8
[7]   Voidage variation in packed beds at small column to particle diameter ratio [J].
de Klerk, A .
AICHE JOURNAL, 2003, 49 (08) :2022-2029
[8]   Octopus, a fast and user-friendly tomographic reconstruction package developed in LabView® [J].
Dierick, M ;
Masschaele, B ;
Van Hoorebeke, L .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (07) :1366-1370
[9]   CATALYST EFFECTIVENESS FACTOR AND CONTACTING EFFICIENCY IN TRICKLE-BED REACTORS [J].
DUDUKOVIC, MP .
AICHE JOURNAL, 1977, 23 (06) :940-944
[10]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619