NEUTRON FIELD CHARACTERISATION OF THE OB26 CRNA IRRADIATOR IN VIEW OF ITS USE FOR CALIBRATION PURPOSES

被引:15
作者
Mazrou, Hakim [1 ]
Sidahmed, Tassadit [1 ]
Allab, Malika [2 ]
机构
[1] CRNA, Algiers 16000, RP, Algeria
[2] USTHB, Fac Phys, Algiers 16111, Algeria
关键词
SOURCE SPECTRUM; SPECTROMETRY; FLUENCE;
D O I
10.1093/rpd/ncq166
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The main goal of the present work is to characterise the neutron field of an OB26 irradiation system acquired by the Nuclear Research Center of Algiers for radiation protection purposes. Extensive Monte-Carlo (MC) calculations and measurements using BF(3-) and (3)He-based neutron area dosemeters were performed to estimate the contribution, on the energy neutron spectrum, of each component present in the bunker facility of the Algerian Secondary Standard Dosimetry Laboratory (SSDL) where the irradiator has been installed. For this purpose, new irradiation configurations based on the (241)Am Be source placed in the OB 26/2 biological shielding inside its environment have been investigated by MC simulations, and comparison with the ISO spectrum has been performed. During MC simulations, sensitivity analysis has been considered to estimate the effect of several physical parameters on the neutron fluence and dose equivalent rates. In addition, the contribution of the gamma dose equivalent rates to the total neutron dose equivalent rates was estimated for both selected source detector distances (SDDs) 150 and 200 cm. Finally, a theoretical approach has been adopted, using MCNP5 fluence rates, to estimate the readings of the instruments taking into account their response functions. A low mean difference (12 %) between measured and predicted dose equivalent rates for two selected SDDs has been observed. Overall, the obtained MCNP5 results regarding the actual SSDL irradiation facility are particularly encouraging, but need to be supported by further experimental data.
引用
收藏
页码:114 / 126
页数:13
相关论文
共 23 条
[1]  
*AEA QSA TECHN GMB, 2004, DESCR DRAW X14 X14 1
[2]  
AEA QSA-TECHNOLOGY/GmBH, 2000, SOURC MAN
[3]   Neutron spectrometry in mixed fields: Multisphere spectrometers [J].
Alevra, AV ;
Thomas, DJ .
RADIATION PROTECTION DOSIMETRY, 2003, 107 (1-3) :37-72
[4]  
[Anonymous], 2021, ISO8529-2
[5]  
Bardell A. G., 1998, 24 NPL CIRM
[6]  
BENMOKHTAR S, 2000, CALIBRATION AREA SUR
[7]  
*BERTH TECHN, 6411 LB BERTH TECHN
[8]   The neutron fluence and H*(10) response of the new LB 6411 rem counter [J].
Burgkhardt, B ;
Fieg, G ;
Klett, A ;
Plewnia, A ;
Siebert, BRL .
RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) :361-364
[9]  
DANNER R, 2006, RPD016 HPA
[10]   Characteristics of the neutron field of the facility at DIN-UPM [J].
Gallego, E ;
Lorente, A ;
Vega-Carrillo, HR .
RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) :73-79