Electrical behavior of defibrillation and pacing electrodes

被引:4
作者
Kim, YM
Schimpf, PH
机构
[1] Department of Electrical Engineering, University of Washington, Seattle, WA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/5.486746
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article discussed the electrodes and their interfaces for internal and external defibrillation and external pacing applications. Of primary concern is the nature of the current delivery and distribution at the electrode-tissue interface and the techniques that may be used to generate a uniform distribution of current density in order to minimize pain and burning. The cost of achieving a uniform current distribution is tolerable for external pacing applications, but questionable for defibrillation applications. In the process of examining the nature of the electrode interface, we also discuss various models of its behavior including analytic equivalent circuit, numerical, and empirical models.
引用
收藏
页码:446 / 456
页数:11
相关论文
共 35 条
[11]  
Fricke R, 1932, PHILOS MAG, V14, P310
[12]  
GEDDES LA, 1975, P CARDIAC DEFIBRILLA, P45
[14]   A SUBCUTANEOUS LEAD ARRAY FOR IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS [J].
JORDAENS, L ;
VERTONGEN, P ;
VANBELLEGHEM, Y .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (07) :1429-1433
[15]   PREDICTING CARDIOTHORACIC VOLTAGES DURING HIGH-ENERGY SHOCKS - METHODOLOGY AND COMPARISON OF EXPERIMENTAL TO FINITE-ELEMENT MODEL DATA [J].
JORGENSON, DB ;
SCHIMPF, PH ;
SHEN, I ;
JOHNSON, G ;
BARDY, GH ;
HAYNOR, DR ;
KIM, YM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (06) :559-571
[16]   COMPUTATIONAL STUDIES OF TRANSTHORACIC AND TRANSVENOUS DEFIBRILLATION IN A DETAILED 3-D HUMAN THORAX MODEL [J].
JORGENSON, DB ;
HAYNOR, DR ;
BARDY, GH ;
KIM, YM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (02) :172-184
[17]   OPTIMAL ELECTRODE DESIGNS FOR ELECTROSURGERY, DEFIBRILLATION, AND EXTERNAL CARDIAC PACING [J].
KIM, Y ;
BENFAHY, J ;
TUPPER, BJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (09) :845-853
[18]   FARADIC RESISTANCE OF THE ELECTRODE ELECTROLYTE INTERFACE [J].
MAYER, S ;
GEDDES, LA ;
BOURLAND, JD ;
OGBORN, L .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (05) :538-542
[19]   A PHYSICAL INTERPRETATION OF SCHWAN LIMIT CURRENT OF LINEARITY [J].
MCADAMS, ET ;
JOSSINET, J .
ANNALS OF BIOMEDICAL ENGINEERING, 1992, 20 (03) :307-319
[20]   LINEAR AND NON-LINEAR PROPERTIES OF PLATINUM-ELECTRODE POLARIZATION .2. TIME DOMAIN ANALYSIS [J].
ONARAL, B ;
SCHWAN, HP .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (02) :210-216