Detection of hypotension during spinal anesthesia for caesarean section with continuous non-invasive arterial pressure monitoring and intermittent oscillometric blood pressure monitoring in patients treated with ephedrine or phenylephrine

被引:0
|
作者
Vukotic, Aleksandra [1 ]
Jevdjic, Jasna [2 ,3 ]
Green, David [4 ]
Vukotic, Milovan [5 ]
Petrovic, Nina [6 ]
Janicijevic, Ana [1 ]
Nenadic, Irina [1 ]
Bobos, Marina [1 ]
Culjic, Radmila [1 ]
Zagorac, Zagor [7 ]
Stevanovic, Predrag [1 ,8 ]
机构
[1] Dr Dragisa Misovic Dedinje Univ Clin Hosp Ctr, Clin Anesthesiol & Reanimatol, Heroja Milana Tepica 1, Belgrade 11000, Serbia
[2] Univ Kragujevac, Fac Med Sci, Kragujevac, Serbia
[3] Clin Ctr Kragujevac, Dept Anesthesiol & Reanimat, Kragujevac, Serbia
[4] Kings Coll Hosp NHS Fdn Trust, Dept Anesthet Intens Care & Pain Relief, London, England
[5] Banjica Inst Orthoped Surg, Dept Anesthesia Reanimatol & Intens Care, Belgrade, Serbia
[6] Univ Belgrade, Vinca Inst Nucl Sci, Natl Inst Republ Serbia, Dept Hlth & Environm,Lab Radiobiol & Mol Genet, Belgrade, Serbia
[7] Dr Dragisa Misovic Dedinje Univ Clin Hosp Ctr, Clin Surg, Belgrade, Serbia
[8] Univ Belgrade, Fac Med, Belgrade, Serbia
关键词
spinal anesthesia; cesarean section; hemodynamic monitoring; hypotension; INFUSION;
D O I
10.2298/SARH200317030V
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction/Objective Despite frequent side effects such as hypotension, spinal anesthesia (SA) is still one of the best anesthetic methods for elective cesarean section (CS). Intermittent, oscillometric, noninvasive blood pressure monitoring (NIBP) frequently leads to missed hypotensive episodes. The objective was to compare continuous non-invasive arterial pressure (CNAP) monitoring with NIBP in the terms of efficiency to detect hypotension. Methods In this study, we compared CNAP and NIBP monitoring for hypotension detection in 76 patients divided into two groups of 38 patients treated with ephedrine (E) or phenylephrine (P), during threeminute intervals, starting from SA, by the end of the surgery. Results In E group, significantly lower mean systolic blood pressure (SBP) values with CNAP compared with NIBP (p = 0.008) was detected. By monitoring CNAP, we detected 31 (81.6%) hypotensive patients in E group and significantly lower number, 20 (52.6%), with NIBP (p = 0.001), while in P group CNAP detected 34 patients (89.5%) and NIBP only 18 (47.3%), p = 0.001. By monitoring CNAP, we detected significantly higher number of hypotensive intervals in E and P groups (p < 0.001). Umbilical vein pH was lower within hypotensive compared with normotensive patients in E and P groups, with CNAP and NIBP, respectively (p < 0.001, p = 0.027 in E, and p = 0.009, p < 0.001, in P group). Conclusion CNAP is more efficient in hypotension detection for CS during SA, which allows faster treatment of hypotension, thus improving fetal and maternal outcome.
引用
收藏
页码:442 / 448
页数:7
相关论文
共 50 条
  • [31] Comparison of inflationary non-invasive blood pressure (iNIBP) monitoring technology and conventional deflationary non-invasive blood pressure (dNIBP) measurement in detecting hypotension during cesarean section
    Akiko Yamashita
    Shingo Irikoma
    JA Clinical Reports, 4 (1)
  • [32] Continuous Finger-cuff versus Intermittent Oscillometric Arterial Pressure Monitoring and Hypotension during Induction of Anesthesia and Noncardiac Surgery: The DETECT Randomized Trial
    Kouz, Karim
    Weidemann, Friederike
    Naebian, Ashkan
    Lohr, Anneke
    Bergholz, Alina
    Thomsen, Kristen K.
    Krause, Linda
    Petzoldt, Martin
    Moll-Khosrawi, Parisa
    Sessler, Daniel I.
    Flick, Moritz
    Saugel, Bernd
    ANESTHESIOLOGY, 2023, 139 (03) : 298 - 308
  • [33] Continuous intra-arterial versus intermittent oscillometric arterial pressure monitoring and hypotension during induction of anaesthesia: the AWAKE randomised trial
    Kouz, Karim
    Wegge, Mirja
    Flick, Moritz
    Bergholz, Alina
    Moll-Khosrawi, Parisa
    Nitzschke, Rainer
    Trepte, Constantin J. C.
    Krause, Linda
    Sessler, Daniel I.
    Zollner, Christian
    Saugel, Bernd
    BRITISH JOURNAL OF ANAESTHESIA, 2022, 129 (04) : 478 - 486
  • [34] Comparison of inflationary non-invasive blood pressure (iNIBP) monitoring technology and conventional deflationary non-invasive blood pressure (dNIBP) measurement in detecting hypotension during cesarean section
    Yamashita, Akiko
    Irikoma, Shingo
    JA CLINICAL REPORTS, 2018, 4
  • [35] NON-INVASIVE CONTINUOUS MONITORING OF SYSTEMIC BLOOD-PRESSURE
    SPORTICHE, M
    JARDIN, F
    BOUROKBA, A
    MARGAIRAZ, A
    NOUVELLE PRESSE MEDICALE, 1980, 9 (18): : 1306 - &
  • [36] Continuous Non-Invasive Blood Pressure Monitoring Using Photoplethysmography
    Nye, Ross
    Zhang, Zhe
    Fang, Qiang
    2015 INTERNATIONAL SYMPOSIUM ON BIOELECTRONICS AND BIOINFORMATICS (ISBB), 2015, : 176 - 179
  • [37] Evaluation of the oscillometric technique for intermittent non-invasive arterial blood pressure measurement in the anaesthetized pig
    Ypsilantis, P.
    Didilis, V.
    Simopoulos, C.
    LABORATORY ANIMALS, 2013, 47 (02) : 94 - 99
  • [38] Non-invasive intraoperative monitoring of blood pressure and arterial pCO2 during surgical anesthesia in mice
    Thal, Serge C.
    Plesnila, Nikolaus
    JOURNAL OF NEUROSCIENCE METHODS, 2007, 159 (02) : 261 - 267
  • [39] Comparison of continuous non-invasive finger arterial pressure monitoring with conventional intermittent automated arm arterial pressure measurement in patients under general anaesthesia
    Vos, J. J.
    Poterman, M.
    Mooyaart, E. A. Q.
    Weening, M.
    Struys, M. M. R. F.
    Scheeren, T. W. L.
    Kalmar, A. F.
    BRITISH JOURNAL OF ANAESTHESIA, 2014, 113 (01) : 67 - 74
  • [40] Comparison of non invasive measurement of blood pressure at the ankle to the arm during caesarean section under spinal anesthesia
    Yengui, O.
    Jabri, H.
    Thamlaoui, S.
    Tounsi, M.
    Bennasr, L.
    Ben Marzouk, S.
    Maghrebi, H.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2014, 33 : A317 - A317