Comparison of Tono-Pen Avia and Handheld Applanation Tonometry in Primary Congenital Glaucoma

被引:5
作者
Cronemberger, Sebastiao [1 ]
Veloso, Artur W. [1 ]
机构
[1] Univ Fed Minas Gerais, Visual Sci Lab, Dept Ophthalmol & Otorhinolaryngol, Belo Horizonte, MG, Brazil
关键词
primary congenital glaucoma; intraocular pressure; applanation tonometry; Tono-pen; tonometry; ocular; INTRAOCULAR-PRESSURE MEASUREMENTS; GOLDMANN APPLANATION; CORNEAL THICKNESS; OCULAR RIGIDITY; AXIAL LENGTH; ANESTHESIA; DIAMETER; CHILDREN; ICARE; EYE;
D O I
10.1097/IJG.0000000000001820
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: Tono-Pen AVIA (TPA) intraocular pressure (IOP) values are different from those taken with handheld Goldmann applanation tonometer (GAT) in primary congenital glaucoma (PCG). These differences indicate both tonometers cannot be used interchangeably for measuring IOP in PCG. Purpose: The aim was to compare IOP measurements obtained using TPA and a handheld version of GAT in children with PCG. Materials and Methods: Forty-two eyes from 23 patients were evaluated for central corneal thickness (CCT), axial length, biomicroscopy and IOP measurement with TPA and a handheld GAT under inhalation anesthesia. After 1 eye from each patient was randomized, paired the Student t-test and the Pearson correlation were used for analysis. Generalized linear mixed model was used to estimate the difference between tonometers. Results: Mean age of children was 28.3 +/- 20.5 months. Mean axial length was 24.89 +/- 3.33 mm and mean CCT was 605.9 +/- 81.0 mu m. Mean IOP was 22.1 +/- 9.6 for TPA and 14.0 +/- 4.5 mm Hg for GAT. There was a significant difference of 8.1 +/- 6.9 mm Hg between TPA IOP and GAT IOP (P<0.001). Each 6 months increase in age was associated with 1.32 mm Hg reduction in the difference between tonometers (P=0.002) and each 1 mm Hg higher of mean GAT IOP was associated with -0.73 mm Hg in the difference between TPA and GAT (P=0.002). Also, for every 20 mu m increase in CCT an increase of 1.16 mm Hg in the difference between both devices was expected (P=0.003), after adjustment for potentially confounding variables. Conclusion: There is a significant difference between TPA IOP and GAT IOP in PCG. The difference between TPA and GAT in PCG is influenced by CCT, age and GAT IOP value.
引用
收藏
页码:E227 / E230
页数:4
相关论文
共 29 条
[1]   Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods [J].
Arora, R. ;
Bellamy, H. ;
Austin, M. W. .
CLINICAL OPHTHALMOLOGY, 2014, 8 :605-610
[2]  
Bhan A, 2002, INVEST OPHTH VIS SCI, V43, P1389
[3]   Comparative evaluation of TonoPen AVIA, Goldmann applanation tonometry and non-contact tonometry [J].
Bhartiya S. ;
Bali S.J. ;
Sharma R. ;
Chaturvedi N. ;
Dada T. .
International Ophthalmology, 2011, 31 (4) :297-302
[4]   The effects of sevoflurane and ketamine on intraocular pressure in children during examination under anesthesia [J].
Blumberg, Dana ;
Congdon, Nathan ;
Jampel, Henry ;
Gilbert, Donna ;
Elliott, Richard ;
Rivers, Richard ;
Munoz, Beatrice ;
Quigley, Harry .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (03) :494-499
[5]   The Icare-Pro Rebound Tonometer Versus the Hand-held Applanation Tonometer in Congenital Glaucoma [J].
Borrego Sanz, Lara ;
Morales-Fernandez, Laura ;
Martinez de-la-Casa, Jose M. ;
Saenz-Frances, Federico ;
Fuentes, Manuel ;
Garcia-Feijoo, Julian .
JOURNAL OF GLAUCOMA, 2016, 25 (02) :149-154
[6]  
Calixto N., 2006, OFTALMOLOGIA PEDIAT, P251
[7]   Effect of intraocular pressure control on central corneal thickness, horizontal corneal diameter, and axial length in primary congenital glaucoma [J].
Cronemberger, Sebastiao ;
Calixto, Nassim ;
Avellar Milhomens, Thiago Gutemberg ;
Gama, Priscila Ottoni ;
Milhomens, Eduardo Gutemberg ;
Rolim, Hevila ;
Mendonca, Swethlana Calheiros .
JOURNAL OF AAPOS, 2014, 18 (05) :433-436
[8]   Ocular Rigidity, Ocular Pulse Amplitude, and Pulsatile Ocular Blood Flow: The Effect of Axial Length [J].
Dastiridou, Anna I. ;
Ginis, Harilaos ;
Tsilimbaris, Miltiadis ;
Karyotakis, Nikos ;
Detorakis, Efstathios ;
Siganos, Charalambos ;
Cholevas, Pierros ;
Tsironi, Evangelia E. ;
Pallikaris, Ioannis G. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (03) :2087-2092
[9]   Positive correlation between Tono-Pen intraocular pressure and central corneal thickness [J].
Dohadwala, AA ;
Munger, R ;
Damji, KF .
OPHTHALMOLOGY, 1998, 105 (10) :1849-1854
[10]  
DRAEGER J., 1967, INVEST OPHTHALMOM, V6, P132