100 000-fold concentration of anions in capillary zone electrophoresis using electroosmotic flow controlled counterflow isotachophoretic stacking under field amplified conditions

被引:80
作者
Breadmore, Michael C. [1 ]
Quirino, Joselito P. [1 ]
机构
[1] Univ Tasmania, Sch Chem, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
关键词
D O I
10.1021/ac8007835
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electroosmotic flow (EOF) controlled counterflow isotachophoretic stacking boundary (cf-ITPSB) system under field amplified conditions has been examined as a way to improve the sensitivity of anions separated by capillary zone electrophoresis. The system comprised a high concentration of a high-mobility leading ion (100 mM chloride) and a low concentration of low-mobility terminating ion (1-3 mM MES or CHES) added to the sample in an unmodified fused-silica capillary at pH 8.05, buffered with Tris. Computer simulation studies using the software GENTRANS showed an increase in sensitivity of at least 10-fold over the previous cf-ITPSB system for simple inorganic ions, nitrite and nitrate. The simulations also suggested that the cf-ITPSB became stationary within the capillary and that its stationary position was not adversely affected by the concentration of MES. This was in contrast to experimental results that showed a slow and continual movement of the cf-ITPSB. This was more pronounced at lower concentrations of terminator (i.e., <3 mM) and resulted in a loss of resolution due to the cf-ITPSB being closer to the detector upon separation. This discrepancy was attributed to the change in pH across the capillary due to electrolysis and low buffering capacity in the sample, a phenomenon that cannot be simulated by the GENTRANS software. Replacement of MES with CHES as a lower mobility ion with increased buffer capacity failed to reduce the movement of the cf-ITPSB but did provide a further 3-fold improvement in sensitivity. ne potential of this approach for sensitivity enhancement was demonstrated for the co-EOF separation of a mixture of six inorganic and small organic ions, with detection limits at the single-figure nanogram per liter level. These detection limits are 100 000 times better than can be achieved by normal hydrodynamic injection (ions prepared in water) and 250 times better than has been achieved by other online preconcentration approaches. The application of the EOF-controlled cf-ITPSB with counter-EOF separation of two pharmaceutical pollutants, naproxen and diflunisal, was also demonstrated with an improvement in sensitivity of 1000 giving detection limits of 350 ng/L in sewage treatment wastewater without any offline pretreatment.
引用
收藏
页码:6373 / 6381
页数:9
相关论文
共 56 条
[1]   ANALYSIS OF DILUTE PEPTIDE SAMPLES BY CAPILLARY ZONE ELECTROPHORESIS [J].
AEBERSOLD, R ;
MORRISON, HD .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :79-88
[2]  
[Anonymous], 1998, J CAN SOC FORENSIC S
[3]   Potential of on-line isotachophoresis-capillary zone electrophoresis with hydrodynamic counterflow in the analysis of various basic proteins and recombinant human interleukin-3 [J].
Bergmann, J ;
Jaehde, U ;
Mazereeuw, M ;
Tjaden, UR ;
Schunack, W .
JOURNAL OF CHROMATOGRAPHY A, 1996, 734 (02) :381-389
[4]   Quantitative trace analysis of interleukin-3, interleukin-6, and basic model proteins using isotachophoresis-capillary zone electrophoresis with hydrodynamic counterflow [J].
Bergmann, J ;
Jaehde, U ;
Schunack, W .
ELECTROPHORESIS, 1998, 19 (02) :305-310
[5]   ELECTROPHORESIS - MATHEMATICAL-MODELING AND COMPUTER-SIMULATION [J].
BIER, M ;
PALUSINSKI, OA ;
MOSHER, RA ;
SAVILLE, DA .
SCIENCE, 1983, 219 (4590) :1281-1287
[6]   CONCEPT OF THE EFFECTIVE MOBILITY OF THE HYDROGEN-ION AND ITS USE IN CATIONIC ISOTACHOPHORESIS [J].
BOCEK, P ;
GEBAUER, P ;
DEML, M .
JOURNAL OF CHROMATOGRAPHY, 1981, 219 (01) :21-28
[7]  
BOCEK P, 1981, J CHROMATOGR, V217, P209
[8]   On-column ion-exchange preconcentration of inorganic anions in open tubular capillary electrochromatography with elution using transient-isotachophoretic gradients. 3. Implementation and method development [J].
Breadmore, MC ;
Palmer, AS ;
Curran, M ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2002, 74 (09) :2112-2118
[9]  
Breadmore MC, 2001, ELECTROPHORESIS, V22, P2464
[10]   On capillary ion-exchange preconcentration of inorganic anions in open-tubular capillary electrochromatography with elution using transient-isotachophoretic gradients. 2. Characterization of the isotachophoretic gradient [J].
Breadmore, MC ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :820-828