Comparative studies of the behavior of neutral and ionic ferrocene derivatives under different conditions of electrospray ionization

被引:3
|
作者
Nekrasov, Yu S. [1 ]
Ikonnikov, N. S. [1 ]
Belousov, Yu A. [1 ]
Kiselev, S. S. [1 ]
机构
[1] Russia Acad Sci, AN Nesmeyanov Organoelement Cpds Inst, Moscow 119991, Russia
关键词
ferrocene; mass spectrometry; electrospray ionization; desorption electrospray ionization; gas phase; MASS-SPECTROMETRY; MECHANISM; ANALYTES;
D O I
10.1134/S1061934811130132
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have studied the behavior of ferrocene CpFeCp (FcH), ferrocenium triiodide [FcH]I+ (3) (-) , dimethylaminomethylferrocene FcCH(2)NMe(2) and its trimethylammonium salt [FcCH(2)NMe(3)]I-+(-) under the conventional conditions of electrospray ionization (ESI), when the substance solution is subjected to spraying, and in two versions of desorption electrospray ionization (DESI), when the sprayed solvent bombards the surface of solid or liquid samples. In addition to these techniques, the behavior of neutral compounds under conditions of electrospray ionization of vapors of the studied compounds in a gas phase (ESI_V) has been investigated. It has been shown using the examples of ferrocene and its dimethylaminomethyl derivative that the detection limits for these compounds occurring in a gas phase are comparable within an order of magnitude with their detection limits under the ESI and DESI conditions of solid and liquid samples. The high effectiveness of ionization of analyte vapors makes it possible to use the ESI method not only in combination with liquid (conventional ESI technology) and thin layer chromatography (DESI), but also with gas liquid chromatography (ESI_V). Thus, the electrospray ionization becomes a universal method allowing studies of a compound under the natural conditions in any state of aggregation, that is, solid, liquid, and gas. With the help of statistical methods for designing experiments (complete factorial experiment), quantitative evaluation of the influence of experimental parameters on the ion-formation processes under different ESI conditions has been carried out, which makes it possible to purposefully select the optimal conditions to record the ESI mass spectra with a minimum number of experiments. Moreover, analysis of the dependences of the mass spectra on the experimental parameters can serve as an instrument for studying the details of the ion-formation mechanisms depending upon different ways of ionization.
引用
收藏
页码:1291 / 1297
页数:7
相关论文
共 50 条
  • [1] Comparative studies of the behavior of neutral and ionic ferrocene derivatives under different conditions of electrospray ionization
    Yu. S. Nekrasov
    N. S. Ikonnikov
    Yu. A. Belousov
    S. S. Kiselev
    Journal of Analytical Chemistry, 2011, 66 : 1291 - 1297
  • [2] On the mechanism of ferrocene oxidation under the conditions of electrospray ionization
    Nekrasov, Yu. S.
    Borisov, Yu. A.
    Skazov, R. S.
    Rodionov, A. N.
    Simenel, A. A.
    Belousov, Yu. A.
    RUSSIAN CHEMICAL BULLETIN, 2009, 58 (07) : 1521 - 1523
  • [3] On the mechanism of ferrocene oxidation under the conditions of electrospray ionization
    Yu. S. Nekrasov
    Yu. A. Borisov
    R. S. Skazov
    A. N. Rodionov
    A. A. Simenel
    Yu. A. Belousov
    Russian Chemical Bulletin, 2009, 58 : 1521 - 1523
  • [4] Ferrocenylalkylation processes under electrospray ionization conditions
    Nekrasov, Yu. S.
    Skazov, R. S.
    Simenel, A. A.
    Snegur, L. V.
    Kachala, I. V.
    RUSSIAN CHEMICAL BULLETIN, 2006, 55 (08) : 1368 - 1371
  • [5] Ferrocenylalkylation processes under electrospray ionization conditions
    Yu. S. Nekrasov
    R. S. Skazov
    A. A. Simenel
    L. V. Snegur
    I. V. Kachala
    Russian Chemical Bulletin, 2006, 55 : 1368 - 1371
  • [6] The reactivity of ferrocenylalkyl azoles under the conditions of electrospray ionization
    Nekrasov, Yu. S.
    Borisov, Yu. A.
    Skazov, R. S.
    Simenel, A. A.
    Snegur, L. V.
    Belousov, Yu. A.
    Rodionov, A. N.
    JOURNAL OF ORGANOMETALLIC CHEMISTRY, 2009, 694 (12) : 1807 - 1812
  • [7] Electrospray ionization deposition of BSA under vacuum conditions
    Hecker, Dominic
    Gloess, Daniel
    Frach, Peter
    Gerlach, Gerald
    SMART SENSORS, ACTUATORS, AND MEMS VII; AND CYBER PHYSICAL SYSTEMS, 2015, 9517
  • [8] COMPARATIVE STUDIES IN HYPERTENSION UNDER DIFFERENT CONTINENTAL CONDITIONS
    GUNTHER, KH
    PIORKOWSKI, P
    LAGUARDIA, AS
    DILBA, V
    JUNES, P
    DELCAMPO, E
    HANDREG, W
    BOHM, R
    BRAUN, H
    NEPHRON, 1987, 47 : 125 - 127
  • [9] MASS-SPECTROMETRIC BEHAVIOR OF LEVOGLUCOSAN UNDER DIFFERENT IONIZATION CONDITIONS AND IMPLICATIONS FOR STUDIES OF CELLULOSE PYROLYSIS
    EVANS, RJ
    MILNE, TA
    SOLTYS, MN
    SCHULTEN, HR
    JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 1984, 6 (03) : 273 - 283
  • [10] Mobility of Proteins in Porous Substrates under Electrospray Ionization Conditions
    Hu, Bin
    Yao, Zhong-Ping
    ANALYTICAL CHEMISTRY, 2016, 88 (11) : 5585 - 5589