Osteotomy and membrane elevation during the maxillary sinus augmentation procedure - A comparative study: piezoelectric device vs. conventional rotative instruments

被引:122
作者
Barone, Antonio [1 ,2 ]
Santini, Stefano [1 ,2 ]
Marconcini, Simone [1 ,2 ]
Giacomelli, Luca [3 ,4 ]
Gherlone, Enrico [5 ]
Covani, Ugo [1 ,2 ]
机构
[1] Univ Genoa, Unit Oral Pathol & Med, Genoa, Italy
[2] Versilia Hosp, Tirren Stomatol Inst, Lido Di Camaiore, Lucca, Italy
[3] Univ Genoa, Nanoworld Inst, CIRNNOB, Genoa, Italy
[4] Univ Genoa, Div Biophys, Genoa, Italy
[5] Univ Milan, Hosp San Raffaele, Milan, Italy
关键词
bone cutting; maxillary sinus augmentation; piezosurgery;
D O I
10.1111/j.1600-0501.2007.01498.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of the present study was to investigate in a randomized-controlled clinical trial the performance of rotary instruments compared with a piezoelectric device during maxillary sinus floor elevation. Materials and methods: Thirteen patients who required a bilateral maxillary sinus augmentation for implant-prosthetic rehabilitation were included in this study. A within-patient control study was carried out. The osteotomy for sinus access was performed on one side of the maxilla using the piezosurgery (test sites) and on the other side using conventional rotary diamond burs (control sites). The parameters recorded were as follows: bony window length (L), bony window height (H), bone thickness (T) and osteotomy area (A) - calculated by multiplying L and H. In addition, the time necessary for the osteotomy and sinus membrane elevation as well as the number of surgical complications were calculated. Results: The mean length and height of the bone window were similar in both groups. The osteotomy area (A) obtained by multiplying L and H was wider in the control group (151.2 +/- 20.4 mm(2)) compared with the test group (137 +/- 24.2 mm(2)). The time necessary for the osteotomy and the sinus membrane elevation with conventional instruments was 10.2 +/- 2.4 min, while with the piezoelectric device it was 11.5 +/- 3.8 min. Moreover, membrane perforation occurred in 30% of the maxillary sinuses in the test group and in 23% of the control group. None of the differences observed between the two groups reached a level of significance. Conclusions: Within the limits of the present study, it may be concluded that piezosurgery and conventional instruments did not show any differences in the clinical parameters investigated for the maxillary sinus floor elevation.
引用
收藏
页码:511 / 515
页数:5
相关论文
共 20 条
[1]  
Barone A, 2006, INT J ORAL MAX IMPL, V21, P81
[2]  
BOYNE PJ, 1980, J ORAL SURG, V38, P613
[3]   RECONSTRUCTIVE PREPROSTHETIC SURGERY .1. ANATOMICAL CONSIDERATIONS [J].
CAWOOD, JI ;
HOWELL, RA .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1991, 20 (02) :75-82
[4]   Autogenous bone chips:: influence of a new piezoelectric device (Piezosurgery®) on chip morphology, cell viability and differentiation [J].
Chiriac, G ;
Herten, M ;
Schwarz, F ;
Rothamel, D ;
Becker, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (09) :994-999
[5]  
Emam TA, 2003, ANN SURG, V237, P186
[6]   Transrectal high intensity focused ultrasound for the treatment of localized prostate cancer:: Factors influencing the outcome [J].
Gelet, A ;
Chapelon, JY ;
Bouvier, R ;
Rouvière, O ;
Lyonnet, D ;
Dubernard, JM .
EUROPEAN UROLOGY, 2001, 40 (02) :124-129
[7]   Ultrasonic surgery - an alternative way in orthognathic surgery of the mandible - A pilot study [J].
Gruber, RM ;
Kramer, FJ ;
Merten, HA ;
Schliephake, H .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (06) :590-593
[8]   Piezoelectric osteotomy in hand surgery:: first experiences with a new technique [J].
Hoigne, DJ ;
Stübinger, S ;
Von Kaenel, O ;
Shamdasani, S ;
Hasenboehler, P .
BMC MUSCULOSKELETAL DISORDERS, 2006, 7 (1)
[9]   SIMULTANEOUS MAXILLARY SINUS FLOOR BONE-GRAFTING AND PLACEMENT OF HYDROXYLAPATITE-COATED IMPLANTS [J].
KENT, JN ;
BLOCK, MS .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1989, 47 (03) :238-242
[10]  
Khoury F, 1999, INT J ORAL MAX IMPL, V14, P557