Thermally-actuated, phase change flow control for microfluidic systems

被引:53
作者
Chen, ZY [1 ]
Wang, J [1 ]
Qian, SZ [1 ]
Bau, HH [1 ]
机构
[1] Univ Penn, Dept Mech Engn & Appl Mech, Philadelphia, PA 19104 USA
关键词
D O I
10.1039/b508275g
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An easy to implement, thermally-actuated, noninvasive method for flow control in microfluidic devices is described. This technique takes advantage of the phase change of the working liquid itself - the freezing and melting of a portion of a liquid slug - to noninvasively close and open flow passages ( referred to as a phase change valve). The valve was designed for use in a miniature diagnostic system for detecting pathogens in oral fluids at the point of care. The paper describes the modeling, construction, and characteristics of the valve. The experimental results favorably agree with theoretical predictions. In addition, the paper demonstrates the use of the phase change valves for flow control, sample metering and distribution into multiple analysis paths, sealing of a polymerase chain reaction (PCR) chamber, and sample introduction into and withdrawal from a closed loop. The phase change valve is electronically addressable, does not require any moving parts, introduces only minimal dead volume, is leakage and contamination free, and is biocompatible.
引用
收藏
页码:1277 / 1285
页数:9
相关论文
共 24 条
[11]  
Griss P, 2002, LAB CHIP, V2, P117, DOI [10.1039/b111040n, 10.1039/b11040n]
[12]   Ice valve for a mini/micro flow channel [J].
Gui, L ;
Liu, J .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (02) :242-246
[13]   Ferrofluid-based microchip pump and valve [J].
Hartshorne, H ;
Backhouse, CJ ;
Lee, WE .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (2-3) :592-600
[14]   Capillary-based fully integrated and automated system for nanoliter polymerase chain reaction analysis directly from cheek cells [J].
He, Y ;
Zhang, YHH ;
Yeung, ES .
JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) :271-284
[15]   Microfluidic valve with cored glass microneedle for microinjection [J].
Lee, S ;
Jeong, W ;
Beebe, DJ .
LAB ON A CHIP, 2003, 3 (03) :164-167
[16]   Single-use, thermally actuated paraffin valves for microfluidic applications [J].
Liu, RH ;
Bonanno, J ;
Yang, JN ;
Lenigk, R ;
Grodzinski, P .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 98 (2-3) :328-336
[17]   Monolithic valves for microfluidic chips based on thermoresponsive polymer gels [J].
Luo, QZ ;
Mutlu, S ;
Gianchandani, YB ;
Svec, F ;
Fréchet, JMJ .
ELECTROPHORESIS, 2003, 24 (21) :3694-3702
[18]   Phase change microvalve for integrated devices [J].
Pal, R ;
Yang, M ;
Johnson, BN ;
Burke, DT ;
Burns, MA .
ANALYTICAL CHEMISTRY, 2004, 76 (13) :3740-3748
[19]   Polymer micro valve with a hydraulic piezo-drive fabricated by the AMANDA process [J].
Rogge, T ;
Rummler, Z ;
Schomburg, WK .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 110 (1-3) :206-212
[20]   Microfluidic control using colloidal devices [J].
Terray, A ;
Oakey, J ;
Marr, DWM .
SCIENCE, 2002, 296 (5574) :1841-1844