Experimental study on the performance of evaporator and condenser heat exchangers in a train-used air conditioning group

被引:0
作者
Xia, JJ [1 ]
Teodorese, V [1 ]
Georges, B [1 ]
Mazy, C [1 ]
Lebrun, J [1 ]
机构
[1] Tsing Hua Univ, Dept Bldg Sci, Hsinchu, Taiwan
来源
PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2 | 2003年
关键词
finned coil heat exchanger; experimental study; result standardization; evaporator; condenser; capacity;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the measuring procedure, the experimental results and the evaluation for the air conditioning group used in a high-speed train compartment. The target of these tests is to determine the evaporator and condenser performance at the given design conditions. The finned coil condenser and evaporator are installed in air ducts and to control the flow going through the heat exchangers as recommended for the air-heated and air-cooled heat exchangers specific test (ASHRAE Standard 33-1978R, 1999, European Standard EN 1216, 1999). The evaporator and the condenser of the air conditioning group are tested separately in order to have the better control for reaching the design conditions. A simulation model is also developed here to standardize the test results to the required conditions.
引用
收藏
页码:750 / 759
页数:10