Experimental investigation of rectangular concrete-filled fiber reinforced polymer (FRP)-steel composite tube columns for various corner radii

被引:100
作者
Wei, Yang [1 ]
Zhang, Yirui [1 ]
Chai, Jile [1 ]
Wu, Gang [2 ]
Dong, Zhiqiang [2 ]
机构
[1] Nanjing Forestry Univ, Coll Civil Engn, Nanjing 210037, Jiangsu, Peoples R China
[2] Southeast Univ, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Nanjing 210096, Peoples R China
关键词
Concrete; Rectangular columns; Confinement; Composite tube; Corner radius; Models; FRP-CONFINED CONCRETE; STRESS-STRAIN MODEL; TUBULAR STUB COLUMNS; STEEL-TUBE; COMPRESSIVE BEHAVIOR; SQUARE; PERFORMANCE;
D O I
10.1016/j.compstruct.2020.112311
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
To study the compressive behavior of rectangular concrete-filled fiber reinforced polymer (FRP)-steel composite tube (CFCT) columns, twenty-nine specimens were tested under compression loading in five series based on the corner radius. The variables are the corner radius of cross-section, the number of layers of FRP and the type of FRP wrapping. The experimental results revealed that the FRP wrapping may effectively suppress the local buckling for the steel tubes prior to FRP rupturing. The FRP fractures occurred at the corners in the middle of the specimens or at the longitudinal weld seams due to local stress concentrations. The stress-strain curves are influenced significantly by the corner radii for the rectangular CFCT columns. As the corner radius is increased, the linear ascending or descending slopes after the peak points of the stress-strain curve is generally enhanced, and a descending curve can be transformed into an ascending curve. For a given FRP confinement, the ultimate strength increased with increasing corner radius. Based on the experimental results and collected test data, a unified model with a simple and unified expression for predicting ultimate axial strength considering the shape and corner radius of the cross-section was proposed for the CFCT columns.
引用
收藏
页数:12
相关论文
共 60 条
[1]   Structural applications of fibre reinforced polymer (FRP) composite tubes: A review of columns members [J].
Al-saadi, Ali Umran ;
Aravinthan, Thiru ;
Lokuge, Weena .
COMPOSITE STRUCTURES, 2018, 204 :513-524
[2]  
[Anonymous], J COMPOS CONSTR
[3]   Stress-strain relationship of FRP confined concrete columns under combined axial load and bending moment [J].
Cao, Yugui ;
Wu, Yu-Fei ;
Jiang, Cheng .
COMPOSITES PART B-ENGINEERING, 2018, 134 :207-217
[4]  
Che Y, 2012, ADV STEEL CONSTR, V8, P331
[5]   Analytical Model of Circular CFRP Confined Concrete-Filled Steel Tubular Columns under Axial Compression [J].
Choi, Kang-Kyu ;
Xiao, Yan .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (01) :125-133
[6]   Mechanical behavior of elliptical concrete-filled steel tubular stub columns under axial loading [J].
Ding, Fa-xing ;
Ding, Xing-zhi ;
Liu, Xue-mei ;
Wang, Hai-bo ;
Yu, Zhi-wu ;
Fang, Chang-jing .
STEEL AND COMPOSITE STRUCTURES, 2017, 25 (03) :375-388
[7]   Behavior of steel-reinforced concrete-filled square steel tubular stub columns under axial loading [J].
Ding, Fa-xing ;
Zhang, Tao ;
Liu, Xue-mei ;
Lu, Zhao-Hui ;
Guo, Qiang ;
Jiang, Guo-shuai .
THIN-WALLED STRUCTURES, 2017, 119 :737-748
[8]   Correlation analysis of tensile strength and chemical composition of basalt fiber roving [J].
Ding, Lining ;
Liu, Ying ;
Liu, Jianxun ;
Wang, Xin .
POLYMER COMPOSITES, 2019, 40 (07) :2959-2966
[9]   Mechanical properties of pultruded basalt fiber-reinforced polymer tube under axial tension and compression [J].
Ding, Lining ;
Liu, Xia ;
Wang, Xin ;
Huang, Hongjiao ;
Wu, Zhishen .
CONSTRUCTION AND BUILDING MATERIALS, 2018, 176 :629-637
[10]   Experimental behavior and design method of rectangular concrete-filled tubular columns using Q460 high-strength steel [J].
Du, Yansheng ;
Chen, Zhihua ;
Xiong, Ming-Xiang .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 125 :856-872