Effect of platform switching on peri-implant bone levels: a randomized clinical trial

被引:67
作者
Enkling, Norbert [1 ]
Joehren, Peter [2 ]
Klimberg, Victoria
Bayer, Stefan [3 ]
Mericske-Stern, Regina
Jepsen, Soren [4 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Prosthodont, CH-3010 Bern, Switzerland
[2] Univ Witten Herdecke, Dept Oral Surg, Witten, Germany
[3] Univ Bonn, Dept Prosthet Dent Propaedeut & Mat Sci, D-5300 Bonn, Germany
[4] Univ Bonn, Dept Periodontol Operat & Prevent Dent, D-5300 Bonn, Germany
关键词
bacteria; bone level; bone loss; dental implants; implant design; platform switching; SUBMERGED TITANIUM IMPLANTS; HISTOMETRIC EVALUATION; DENTAL IMPLANTS; RELIABILITY; MICROGAP; DOGS; RESTORATIONS; RADIOGRAPHY; DENTISTRY; ACCURACY;
D O I
10.1111/j.1600-0501.2010.02090.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The concept of platform switching has been introduced to implant dentistry based on observations of reduced peri-implant bone loss. However, randomized clinical trials are still lacking. This study aimed to test the hypothesis that platform switching has a positive impact on crestal bone-level changes. Material and methods: Two implants with diameters of 4mm were inserted epicrestally into one side of the posterior mandibles of 25 subjects. After 3 months of submerged healing, the reentry surgery was performed. On the randomly placed test implant, an abutment 3.3mm in diameter was mounted, resulting in a horizontal circular step of 0.35mm (platform switching). The control implant was straight, with an abutment 4mm in diameter. Single-tooth crowns were cemented provisionally. All patients were monitored at short intervals over the course of 1 year. Standardized radiographs and microbiological samples from the implants' inner spaces were obtained at baseline (implant surgery), and after 3, 4, and 12 months. Results: After 1 year, the mean radiographic vertical bone loss at the test implants was 0.53 +/- 0.35mm and at the control implants, it was 0.58 +/- 0.55 mm. The mean intraindividual difference was 0.05 +/- 0.56 mm, which is significantly <0.35mm (P = 0.0093, post hoc power 79.9%). The crestal bone-level changes depended on time (P<0.001), but not on platform switching (P = 0.4). The implants' internal spaces were contaminated by bacteria, with no significant differences in the total counts between the test and the control at any time point (P = 0.98). Conclusions: The present randomized clinical trial could not confirm the hypothesis of a reduced peri-implant bone loss at implants restored according to the concept of platform switching.
引用
收藏
页码:1185 / 1192
页数:8
相关论文
共 45 条
[11]  
Brunner E., 2002, Nonparametric analysis of longitudinal data in factorial experiments
[12]   Platform switching and marginal bone-level alterations: the results of a randomized-controlled trial [J].
Canullo, Luigi ;
Fedele, Giampiero Rossi ;
Iannello, Giuliano ;
Jepsen, Soren .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (01) :115-121
[13]  
Cappiello M, 2008, INT J PERIODONT REST, V28, P347
[14]  
Cocchetto R, 2010, INT J PERIODONT REST, V30, P163
[15]   Bone Response to Loaded Implants With Non-Matching Implant-Abutment Diameters in the Canine Mandible [J].
Cochran, David L. ;
Bosshardt, Dieter D. ;
Grize, Leticia ;
Higginbottom, Frank L. ;
Jones, Archie A. ;
Jung, Ronald E. ;
Wieland, Marco ;
Dard, Michel .
JOURNAL OF PERIODONTOLOGY, 2009, 80 (04) :609-617
[16]  
Crespi R, 2009, INT J ORAL MAX IMPL, V24, P920
[17]   The accuracy and reliability of radiographic methods for the assessment of marginal bone level around oral implants [J].
De Smet, E ;
Jacobs, R ;
Gijbels, F ;
Naert, I .
DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (03) :176-181
[18]  
Deppe H, 2004, INT J ORAL MAX IMPL, V19, P208
[19]   A posteriori registration and subtraction of panoramic compared with intraoral radiography [J].
Deserno, Thomas M. ;
Rangarajan, Janaki Raman ;
Hoffmann, Jens ;
Braegger, Urs ;
Mericske-Stern, Regina ;
Enkling, Norbert .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (02) :E39-E45
[20]   Radiographical and histological characteristics of submerged and non-submerged titanium implants - An experimental study in the Labrador dog [J].
Ericsson, I ;
Nilner, K ;
Klinge, B ;
Glantz, PO .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (01) :20-26