Evaluation of retrospectively ECG-gated 4-row multidetector CT in patients planned for minimal invasive coronary artery bypass grafting

被引:5
作者
Begemann, PGC
Arnold, M
Detter, C
Boehm, DH
Ittrich, H
Koops, A
Reichenspurner, H
Adam, G
Weber, C
机构
[1] Univ Hamburg, Hosp Eppendorf, Klin & Poliklin Diagnost & Intervent Radiol, Radiol Zentrum, D-20246 Hamburg, Germany
[2] Univ Hamburg, Hosp Eppendorf, Herzzentrum, D-20246 Hamburg, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2005年 / 177卷 / 08期
关键词
minimal invasive direct coronary artery bypass grafting; MIDCAB; off-pump coronary artery bypass grafting; OPCAB; multidetector spiral CT; MDCT; cardiac CT; coronary CTA;
D O I
10.1055/s-2005-858369
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Minimal invasive direct coronary artery bypass grafting (MIDCAB) or off-pump coronary artery bypass grafting (OPCAB) on the beating heart with full or mini-sternotomy are becoming more common in coronary bypass surgery of the left anterior descending (LAD). In the decision, which surgical approach (MIDCAB, OPCAB or conventional surgery with cardiopulmonary bypass) will be best used, knowledge of the anatomical field is of major importance. The aim of the study was to evaluate retrospective ECG-gated 4-row multidetector CT (MDCT) in patients planned for MIDCAB as additional imaging to coronary angiography. Material and Methods: The study included 25 consecutive patients. MSCT was performed as unenhanced (collimation 4x2.5 mm) and contrast-enhanced examination (140-170 ml, 300 mg Iodine/ml, collimation 4x1 mm). The evaluation included presence of LAD calcifications, distance of LAD and left internal mammarian artery (LIMA), course of LAD and LIMA, the presence or absence of bridging through myocardium or epicardial fat and the presence of pleural fibrosis. The MDCT results were correlated with intra-operative findings. Results: All MDCTs could be assessed with reference to the demands. In 20/25 operations, MDCT had direct influence as to the selection of the surgical approach (11 MIDCAB, 7 OPCAB with mini-sternotomy and 5 with full sternotomy, 2 conventional surgeries). The distance of LAD and LIMA varied from 0.9 to 4.5 cm in MDCT. As to calcifications, 3/25 correlated patients had calcifications and 10 patients had no calcifications in the middle LAD. Seven patients had intraoperative fibrosis of the vessel wall without calcification of the middle LAD, which could not be detected with MDCT. Another 5 patients had single calcified plaques in the middle LAD, 4 of these had a fibrosis of the vessel and 1 had a normal vessel at surgery. In these cases, the anastomosis was done between the calcified plaques. No myocardial bridging was detected by MDCT and at surgery. Bridging of epicardial fat was shown by MDCT and at surgery in 9/25 patients and was excluded in 15 patients. In 1 patient, the LAD seemed to run superficially in MDCT, but was covered with fat as seen during surgery. The course of the LIMA was inconspicuous in all cases, no pleural fibrosis was found. Conclusions: The 4-row MDCT has proven to be adequate in addition to coronary angiography for preoperative evaluation in patients scheduled for MIDCAB and provides the surgeon with relevant information for the selection of the operative approach.
引用
收藏
页码:1084 / +
页数:9
相关论文
共 25 条
  • [1] Achenbach S, 2001, CIRCULATION, V103, P2535
  • [2] QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY
    AGATSTON, AS
    JANOWITZ, WR
    HILDNER, FJ
    ZUSMER, NR
    VIAMONTE, M
    DETRANO, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) : 827 - 832
  • [3] Technical aspects of total revascularization in off-pump coronary bypass via sternotomy approach
    Baumgartner, FJ
    Gheissari, A
    Capouya, ER
    Panagiotides, GP
    Katouzian, A
    Yokoyama, T
    [J]. ANNALS OF THORACIC SURGERY, 1999, 67 (06) : 1653 - 1658
  • [4] BEGEMANN P, 2004, ROFO FORTSCHR RONTG, V176, P215
  • [5] Radiation exposure in multi-slice CT of the heart
    Cohnen, M
    Poll, L
    Püttmann, C
    Ewen, K
    Mödder, U
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04): : 295 - 299
  • [6] Detter C, 2002, HEART SURG FORUM, V5, P157
  • [7] Single vessel revascularization with beating heart techniques -: minithoracotomy or sternotomy?
    Detter, C
    Reichenspurner, H
    Boehm, DH
    Thalhammer, M
    Schütz, A
    Reichart, B
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 19 (04) : 464 - 470
  • [8] DETTER C, 2004, ARZTEBLATT, V9, P382
  • [9] Flohr T, 2003, HERZ, V28, P7, DOI 10.1007/s00059-003-2456-1
  • [10] New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging
    Flohr, T
    Bruder, H
    Stierstorfer, K
    Simon, J
    Schaller, S
    Ohnesorge, B
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08): : 1022 - 1027