<mml; math altimg="urn; x-wiley; 07403194; media; mrm28160; mrm28160-math-0003"><mml; msub><mml; mi>T</mml; mi><mml; mn>1</mml; mn></mml; msub></mml; math> mapping; mrm28160-math-0004"><mml; msubsup><mml; mn>2</mml; mn><mml; mo>*</mml; mo></mml; msubsup></mml; magnetic resonance fingerprinting; quantitative kidney imaging; TISSUE OXYGENATION; MRI; SENSITIVITY; RECONSTRUCTION;
D O I
10.1002/mrm.28160
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the use of magnetic resonance fingerprinting (MRF) for simultaneous quantification of T1 and T2* in a single breath-hold in the kidneys. Methods The proposed kidney MRF sequence was based on MRF echo-planar imaging. Thirty-five measurements per slice and overall 4 slices were measured in 15.4 seconds. Group matching was performed for in-line quantification of T1 and T2*. Images were acquired in a phantom and 8 healthy volunteers in coronal orientation. To evaluate our approach, region of interests were drawn in the kidneys to calculate mean values and standard deviations of the T1 and T2* times. Precision was calculated across multiple repeated MRF scans. Gaussian filtering is applied on baseline images to improve SNR and match stability. Results T1 and T2* times acquired with MRF in the phantom showed good agreement with reference measurements and conventional mapping methods with deviations of less than 5% for T1 and less than 10% for T2*. Baseline images in vivo were free of artifacts and relaxation times yielded good agreement with conventional methods and literature (deviation T1:7 +/- 4%, T2*:6 +/- 3%). Conclusions In this feasibility study, the proposed renal MRF sequence resulted in accurate T1 and T2* quantification in a single breath-hold.
引用
收藏
页码:1940 / 1948
页数:9
相关论文
共 53 条
  • [1] Spatiotemporal magnetic field monitoring for MR
    Barmet, Christoph
    De Zanche, Nicola
    Pruessmann, Klaas P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) : 187 - 197
  • [2] Burnier M, 2018, NEPHROL DIAL TRANSPL, V33, pii22
  • [3] A medical device-grade T1 and ECV phantom for global T1 mapping quality assurance-the T1 Mapping and ECV Standardization in cardiovascular magnetic resonance (T1MES) program
    Captur, Gabriella
    Gatehouse, Peter
    Keenan, Kathryn E.
    Heslinga, Friso G.
    Bruehl, Ruediger
    Prothmann, Marcel
    Graves, Martin J.
    Eames, Richard J.
    Torlasco, Camilla
    Benedetti, Giulia
    Donovan, Jacqueline
    Ittermann, Bernd
    Boubertakh, Redha
    Bathgate, Andrew
    Royet, Celine
    Pang, Wenjie
    Nezafat, Reza
    Salerno, Michael
    Kellman, Peter
    Moon, James C.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18 : 1 - 20
  • [4] Fast group matching for MR fingerprinting reconstruction
    Cauley, Stephen F.
    Setsompop, Kawin
    Ma, Dan
    Jiang, Yun
    Ye, Huihui
    Adalsteinsson, Elfar
    Griswold, Mark A.
    Wald, Lawrence L.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) : 523 - 528
  • [5] Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure
    Chang, Hing-Chiu
    Chen, Nan-Kuei
    [J]. MAGNETIC RESONANCE IMAGING, 2016, 34 (07) : 974 - 979
  • [6] Chen NK, 1999, MAGNET RESON MED, V41, P1206, DOI 10.1002/(SICI)1522-2594(199906)41:6<1206::AID-MRM17>3.0.CO
  • [7] 2-L
  • [8] MR Fingerprinting for Rapid Quantitative Abdominal Imaging
    Chen, Yong
    Jiang, Yun
    Pahwa, Shivani
    Ma, Dan
    Lu, Lan
    Twieg, Michael D.
    Wright, Katherine L.
    Seiberlich, Nicole
    Griswold, Mark A.
    Gulani, Vikas
    [J]. RADIOLOGY, 2016, 279 (01) : 278 - 286
  • [9] Cohen O., 2017, DEEP LEARNING RAPID
  • [10] Multiparametric Renal Magnetic Resonance Imaging: Validation, Interventions, and Alterations in Chronic Kidney Disease
    Cox, Eleanor F.
    Buchanan, Charlotte E.
    Bradley, Christopher
    Prestwich, Benjamin
    Mahmoud, Huda
    Taai, Maarten
    Selby, Nicholas M.
    Francis, Susan T.
    [J]. FRONTIERS IN PHYSIOLOGY, 2017, 8