Square wave anodic stripping determination of silver using a carbon paste electrode modified with a strong acid ion-exchanger

被引:12
作者
Gellon, H [1 ]
González, PS [1 ]
Fontan, CA [1 ]
机构
[1] Univ Nacl San Luis, Fac Quim Bioquim & Farm, Dept Quim Analit Dr carlos B Marone, RA-5700 San Luis, Argentina
关键词
carbon paste electrode; silver analysis; square wave anodic stripping voltammetry; modified carbon paste;
D O I
10.1081/AL-120025253
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chemically modified carbon paste electrode was developed for the determination of silver by incorporating the ion-exchanger Dowex 50 W x 12 into a conventional graphite-Nujol oil paste. Silver(I) was accumulated at the electrode surface from solutions of the sample under open circuit conditions, then reduced at constant potential in a separate 0.1 M HNO3 solution and finally determined by square wave (Osteryoung) anodic stripping voltammetry. The influence of paste composition, acummulation/reduction time, possible interferences and other experimental variables on the height and shape of the anodic peak was examined in detail. For 5 min of accumulation, the linear range was from 1.62 mug L-1 to 0.8 mg L-1 with a detection limit of 0.27 mug L-1. The dynamic range could be extended up to 2.5 mg L-1 (from 0.92 mug L-1 to 2.5 mg L-1) with 20 min of preconcentration. The method showed good tolerance for CU2+, Fe3+, Cd2+, Zn2+, Ph2+, and Au3+. Interference from Hg2+ up to 5 mg L-1 was avoided by masking with EDTA in the preconcentration step.
引用
收藏
页码:2749 / 2765
页数:17
相关论文
共 26 条
[1]   DEVELOPMENT OF A CHEMICALLY MODIFIED ELECTRODE BASED ON CARBON PASTE AND FUNCTIONALIZED SILICA-GEL FOR PRECONCENTRATION AND VOLTAMMETRIC DETERMINATION OF MERCURY(II) [J].
ALEIXO, LM ;
SOUZA, MDB ;
GODINHO, OES ;
NETO, GD ;
GUSHIKEM, Y ;
MOREIRA, JC .
ANALYTICA CHIMICA ACTA, 1993, 271 (01) :143-148
[2]   STUDIES ON THE VOLTAMMETRIC BEHAVIOR OF A 2-MERCAPTOIMIDAZOLE CONTAINING CARBON-PASTE ELECTRODE - DETERMINATION OF TRACES OF SILVER [J].
CAI, XH ;
KALCHER, K ;
NEUHOLD, C ;
GOESSLER, W ;
GRABEC, I ;
OGOREVC, B .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (11) :736-741
[3]   APPLICATIONS OF CHEMICALLY MODIFIED ELECTRODES TO ANALYSIS OF METAL-IONS [J].
CHEEK, GT ;
NELSON, RF .
ANALYTICAL LETTERS, 1978, 11 (05) :393-402
[4]   Analytical applications of graphite electrode modified with bis(diisopropyloxithiophosphon)disulphide [J].
Denchev, ZI ;
Nikolov, NK ;
Ilcheva, L .
TALANTA, 1997, 44 (05) :749-753
[5]  
FARSANG G, 1965, ACTA CHIM HUNG, V45, P257
[6]  
Guo SX, 1999, ELECTROANAL, V11, P891, DOI 10.1002/(SICI)1521-4109(199908)11:12<891::AID-ELAN891>3.0.CO
[7]  
2-9
[8]   DETERMINATION OF SILVER(I) BY CYCLIC VOLTAMMETRY AT IODINE-COATED ELECTRODES [J].
HOURANI, MK .
ANALYST, 1994, 119 (09) :1975-1978
[9]   PRECONCENTRATION AND VOLTAMMETRIC MEASUREMENT OF SILVER(I) WITH A CARBON-PASTE ELECTRODE MODIFIED WITH 2,9-DICHLORO-1,10-PHENANTHROLINE-SURFACTANT [J].
HUNAG, SS ;
CHEN, ZG ;
LI, BF ;
LIN, HG ;
YU, RQ .
ANALYST, 1994, 119 (08) :1859-1862
[10]   THE VERMICULITE-MODIFIED CARBON-PASTE ELECTRODE AS A MODEL SYSTEM FOR PRECONCENTRATING MONO-CATION AND DIVALENT-CATION [J].
KALCHER, K ;
GRABEC, I ;
RABER, G ;
CAI, XH ;
TAVCAR, G ;
OGOREVC, B .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 386 (1-2) :149-156