Long-term effects and potential limits of intratympanic dexamethasone-loaded hydrogels combined with dexamethasone-eluting cochlear electrodes in a low-insertion trauma Guinea pig model

被引:22
作者
Ahmadi, Navid [1 ]
Gausterer, Julia Clara [2 ]
Honeder, Clemens [1 ]
Moetz, Marlene [3 ]
Schoepper, Hanna [3 ]
Zhu, Chengjing [1 ]
Saidov, Nodir [1 ]
Gabor, Franz [2 ]
Arnoldner, Christoph [1 ]
机构
[1] Med Univ Vienna, Dept Otorhinolaryngol Head & Neck Surg, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Univ Vienna, Dept Pharmaceut Technol & Biopharmaceut, Vienna, Austria
[3] Univ Vet Med Vienna, Dept Pathobiol, Inst Anat Histol & Embryol, Vienna, Austria
关键词
Dexamethasone; Cochlear implantation; Insertion trauma; Hearing preservation; Fibrosis; Poloxamer; 407; HEARING-LOSS; INNER-EAR; ACOUSTIC STIMULATION; AUDITORY-SYSTEM; IMPLANTATION; PRESERVATION; MELANIN; MELANOCYTES; EXPRESSION; ALBINO;
D O I
10.1016/j.heares.2019.107825
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Cochlear implantation has become the most effective hearing restoration method and is one of the great advances in modern medicine. Early implants have been continuously developed into more efficient devices, and electro-acoustic stimulation is increasingly expanding the indication criteria for cochlear implants to patients with more residual hearing. Therefore, protecting the cochlear structures and maintaining its intrinsic capacities like residual hearing has become more important than ever before. In the present study, we aimed to assess the long-term protective effects of a dexamethasone-eluting electrode combined with the preoperative intratympanic application of a dexamethasone-loaded thermoreversible hydrogel in a cochlear implant guinea pig model. 40 normal-hearing animals were equally randomized into a control group receiving an unloaded hydrogel and a non-eluting electrode, a group receiving a dexamethasone-loaded hydrogel and a non-eluting electrode, a group receiving an unloaded hydrogel and a dexamethasone-eluting electrode and a group receiving both a dexamethasone-loaded hydrogel and a dexamethasone-eluting electrode. Residual hearing and impedances were investigated during a period of 120 days. Tissue response and histological changes of cochlear structures were analyzed at the end of the experiments. Treatment with dexamethasone did not show a significant protective effect on residual hearing independent of treatment group. Although the majority of the cochleae didn't exhibit any signs of electrode insertion trauma, a small degree of tissue response could be observed in all animals without a significant difference between the groups. Foreign body giant cells and osteogenesis were significantly associated with tissue response. Hair cells, synapsin-1-positive cells and spiral ganglion cells were preserved in all study groups. Cochlear implantation using a dexamethasone-eluting electrode alone and in combination with a dexamethasone-loaded hydrogel significantly protected auditory nerve fibers on day 120. Post-implantation impedances were equal across study groups and remained stable over the duration of the experiment. In this study we were able to show that use of a dexamethasone-eluting electrode alone and in combination with preoperative application of dexamethasone-loaded hydrogel significantly protects auditory nerve fibers. Furthermore, we have shown that a cochlear implantation-associated hearing threshold shift and tissue response may not be completely prevented by the sole application of dexamethasone. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:14
相关论文
共 69 条
  • [11] DIFFERENTIAL SUSCEPTIBILITY TO NOISE-INDUCED PERMANENT THRESHOLD SHIFT BETWEEN ALBINO AND PIGMENTED GUINEA-PIGS
    CONLEE, JW
    ABDULBAQI, KJ
    MCCANDLESS, GA
    CREEL, DJ
    [J]. HEARING RESEARCH, 1986, 23 (01) : 81 - 91
  • [12] Deficiency of Duffy Antigen Receptor for Chemokines Ameliorated Cochlear Damage From Noise Exposure
    Edderkaoui, Bouchra
    Sargsyan, Liana
    Hetrick, Alisa
    Li, Hongzhe
    [J]. FRONTIERS IN MOLECULAR NEUROSCIENCE, 2018, 11
  • [13] Pattern of hearing loss in a rat model of cochlear implantation trauma
    Fayad, JN
    [J]. OTOLOGY & NEUROTOLOGY, 2005, 26 (03) : 447 - 447
  • [14] Mechanisms of programmed cell death signaling in hair cells and support cells post-electrode insertion trauma
    Eshraghi, Adrien A.
    Lang, Dustin M.
    Roell, Jonathan
    Van de Water, Thomas R.
    Garnham, Carolyn
    Rodrigues, Helio
    Guardiola, Mateo
    Gupta, Chhavi
    Mittal, Jeenu
    [J]. ACTA OTO-LARYNGOLOGICA, 2015, 135 (04) : 328 - 334
  • [15] Molecular mechanisms involved in cochlear implantation trauma and the protection of hearing and auditory sensory cells by inhibition of c-jun-N-terminal kinase signaling
    Eshraghi, Adrien A.
    Gupta, Chhavi
    Van de Water, Thomas R.
    Bohorquez, Jorge E.
    Garnham, Carolyn
    Bas, Esperanza
    Talamo, Victoria Maria
    [J]. LARYNGOSCOPE, 2013, 123 : S1 - S14
  • [16] Preservation of hearing in cochlear implant surgery: Advantages of combined electrical and acoustical speech processing
    Gantz, BJ
    Turner, C
    Gfeller, KE
    Lowder, MW
    [J]. LARYNGOSCOPE, 2005, 115 (05) : 796 - 802
  • [17] Hybrid 10 Clinical Trial Preliminary Results
    Gantz, Bruce J.
    Hansen, Marlan R.
    Turner, Christopher W.
    Oleson, Jacob J.
    Reiss, Lina A.
    Parkinson, Aaron J.
    [J]. AUDIOLOGY AND NEURO-OTOLOGY, 2009, 14 : 32 - 38
  • [18] Combined Electric and Acoustic Stimulation With Hearing Preservation: Effect of Cochlear Implant Low-Frequency Cutoff on Speech Understanding and Perceived Listening Difficulty
    Gifford, Rene H.
    Davis, Timothy J.
    Sunderhaus, Linsey W.
    Menapace, Christine
    Buck, Barbara
    Crosson, Jillian
    O'Neill, Lori
    Beiter, Anne
    Segel, Phil
    [J]. EAR AND HEARING, 2017, 38 (05) : 539 - 553
  • [19] Quantitative differences in endolymphatic calcium and endocochlear potential between pigmented and albino guinea pigs
    Gill, SS
    Salt, AN
    [J]. HEARING RESEARCH, 1997, 113 (1-2) : 191 - 197
  • [20] A new electrode for residual hearing preservation in cochlear implantation: first clinical results
    Gstoettner, Wolfgang
    Helbig, Silke
    Settevendemie, Claudia
    Baumann, Uwe
    Wagenblast, Jens
    Arnoldner, Christoph
    [J]. ACTA OTO-LARYNGOLOGICA, 2009, 129 (04) : 372 - 379