Fire Response of Steel Column Trees with End-Plate Connections

被引:4
|
作者
Rezaeian, Abbas [1 ]
Eghbali, Sobhan [1 ]
机构
[1] Shahid Chamran Univ Ahvaz, Dept Civil Engn, Ahvaz 6135741135, Iran
关键词
Column-tree; Moment-resisting frame; End-plate connection; Steel beam; Fire test; Elevated temperature; BEHAVIOR; BEAMS; BOLTS; ASSEMBLIES; JOINTS;
D O I
10.1061/(ASCE)ST.1943-541X.0003139
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of experimental research on the fire response of steel beams and their end-plate connections in column-tree moment-resisting frames (CMRFs). Using subframe assembly, full-scale steel beams with different stub-to-link end-plate connections were tested under a standard fire curve. The failure modes as well as the structural and thermal responses of the beam and the end-plate connections were studied. The influence of critical factors, including bolt grade and flange plate's size, were investigated. The findings of the experimental studies indicate that the beam flexural failure occurs at the temperature of 720 degrees C when deflections surpass the limiting value specified in a relevant British Standard Institution standard. The end-plate connections fail when the temperature exceeds 760 degrees C, while the beam experiences deflections larger than span/20. The results also show that the plate bending, the bolt tensile fracture, and thread stripping control the failure of the end-plate connection in fire conditions. The end-plate connection detail has a considerable effect on the fire performance of the beam, e.g., using Grade 8.8 bolts and thicker plates in the end-plate connection can enhance the fire resistance and rating of the beams and their connections in steel CMRFs.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A connection element for modelling end-plate connections in fire
    Huang, Zhaohui
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (05) : 841 - 853
  • [2] Lateral impact response of end-plate beam-column connections
    A-Rifaie, A.
    Guan, Z. W.
    Jones, S. W.
    Wang, Q.
    ENGINEERING STRUCTURES, 2017, 151 : 221 - 234
  • [3] Fire Response of Steel Beams With Bolted Flange Plate Connections
    Ebrahimzadeh, Marziyeh
    Rezaeian, Abbas
    FIRE TECHNOLOGY, 2022, 58 (01) : 479 - 501
  • [4] FE modelling of bolted steel end-plate moment connections subjected to a standard fire
    Salem, O.
    Hadjisophocleous, G.
    Zalok, E.
    TUBULAR STRUCTURES XIV, 2012, : 615 - 622
  • [5] Fire Resistance of Steel Beam to Column End Plate Connections
    Petrina, Tudor
    WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM 2016, WMCAUS 2016, 2016, 161 : 143 - 149
  • [6] Response characteristics of flush end-plate connections
    Elkady, Ahmed
    ENGINEERING STRUCTURES, 2022, 269
  • [7] Fire Response of Steel Beams With Bolted Flange Plate Connections
    Marziyeh Ebrahimzadeh
    Abbas Rezaeian
    Fire Technology, 2022, 58 : 479 - 501
  • [8] Seismic performance of the extended end-plate high-strength steel beam-to-column connections after fire
    Xu, Jixiang
    Zhang, Yifan
    STRUCTURES, 2024, 70
  • [9] Component Modelling of Flexible End-plate Connections in Fire
    Hu, Ying
    Davison, Buick
    Burgess, Ian
    Plank, Roger
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2009, 9 (01) : 1 - 15
  • [10] Stiffening of bolted end-plate connections with steel member assemblies
    Tagawa, Hiroshi
    Liu, Yudu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 103 : 190 - 199