The effect of mechanical deformation on magnetic properties and MRI artifacts of type 304 and type 316L stainless steel

被引:19
作者
Bendel, LP [1 ]
Shellock, FG [1 ]
Steckel, M [1 ]
机构
[1] Mat Technol Associates, Lebanon, NJ 08833 USA
关键词
stainless steel; MRI; deformation;
D O I
10.1002/jmri.1880070635
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the influence of composition and deformation of biomedical stainless steels on mechanical properties, magnetic properties, and MRI artifacts. Type 304 and Type 316L samples were prepared using standard wire-drawing techniques. Mechanical properties were determined using standard test methods. The amount of ferromagnetic phase present was estimated using a Severn Gage and x-ray diffraction. Magnetic field attraction and artifacts were determined using previously described techniques. The strength of both steels increased significantly with increasing deformation. None of the type 316L wires transformed to the magnetic phase. The amount of magnetic phase in the type 304 wires increased with increasing deformation. There was no magnetic field attraction, and artifacts were minimal for all of type 316L wires and the undeformed type 304 wire. Deflection and artifacts were significant for the deformed type 304 stainless steel. These results provide guidance regarding the use of type 304 and type 316L stainless steels for bioimplants. In this regard, type 316L stainless steel seems to be a more acceptable material with respect to MR compatibility.
引用
收藏
页码:1170 / 1173
页数:4
相关论文
共 18 条
[1]  
[Anonymous], 1995, ANN BOOK ASTM STAND, DOI DOI 10.1520/2002C
[2]  
BARDOS DI, 1977, HDB STAINLESS STEEL
[3]   MR ARTIFACTS - A REVIEW [J].
BELLON, EM ;
HAACKE, EM ;
COLEMAN, PE ;
SACCO, DC ;
STEIGER, DA ;
GANGAROSA, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) :1271-1281
[4]  
DAVIS JR, 1994, ASM SPECIALTY HDB ST, P498
[5]   ANEURYSM CLIP MOTION DURING MAGNETIC-RESONANCE IMAGING - INVIVO EXPERIMENTAL-STUDY WITH METALLURGICAL FACTOR-ANALYSIS [J].
DUJOVNY, M ;
KOSSOVSKY, N ;
KOSSOWSKY, R ;
VALDIVIA, R ;
SUK, JS ;
DIAZ, FG ;
BERMAN, SK ;
CLEARY, W .
NEUROSURGERY, 1985, 17 (04) :543-548
[6]  
FAGAN LL, 1995, JMRI-J MAGN RESON IM, V5, P614
[7]  
HOKE JH, 1977, HDB STAINLESS STEEL
[8]   MR IMAGING IN PATIENTS WITH METALLIC IMPLANTS [J].
LAAKMAN, RW ;
KAUFMAN, B ;
HAN, JS ;
NELSON, AD ;
CLAMPITT, M ;
OBLOCK, AM ;
HAAGA, JR ;
ALFIDI, RJ .
RADIOLOGY, 1985, 157 (03) :711-714
[9]   TANTALUM VASCULAR STENTS - INVIVO EVALUATION WITH MR IMAGING [J].
MATSUMOTO, AH ;
TEITELBAUM, GP ;
BARTH, KH ;
CARVLIN, MJ ;
SAVIN, MA ;
STRECKER, EP .
RADIOLOGY, 1989, 170 (03) :753-755
[10]   MAGNETIC-RESONANCE IMAGING OF POSTOPERATIVE-PATIENTS WITH METALLIC IMPLANTS [J].
MECHLIN, M ;
THICKMAN, D ;
KRESSEL, HY ;
GEFTER, W ;
JOSEPH, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1281-1284